KX-HGT100 Configuration (3)
Download
Report
Transcript KX-HGT100 Configuration (3)
KX-HGT100 SIP-Phone
KX-HGT100 Configuration (1)
1. Connect the HGT100 to the LAN via a suitable switch port
2. Power on the unit (using PoE or the optional AC Adaptor)
3. Check the LCD Display shows
Not
Configured
“Not
configured
WebSetting”
Setting
Web
4. Using your Browser (Internet Explorer etc), access http://192.168.0.241/
User name: KX-HGT100
Password: kx-hgt100
KX-HGT100 Configuration (2)
Unit Status:
Unit has no Profile set.
Registration is not
possible
KX-HGT100 Configuration (3)
Network Status:
STATIC IP is set by default
Default IP:
192.168.0.241
Default Subnet Mask
255.255.255.0
KX-HGT100 Configuration (4)
LAN Connection:
STATIC IP or DHCP Mode
can be selected.
(Static IP is Default = X )
NB: If you select ‘DHCP’ here, you will need to re-connect your browser using the
allocated IP address before continuing to configure.
KX-HGT100 Configuration (5)
Enter IP Address etc
of HGT100 here
DNS Server Address can
be added here
(not required for TDE/NCP)
After clicking ‘Save’, please power off/on the HGT-100
KX-HGT100 Configuration (6)
The allocated IP address can be
checked by pressing the [i+] key on
the HGT-100.
To re-connect with a browser (after
enabling DHCP), enter the allocated
IP address)
i.e. Allocated IP address 10.66.55.44
URL:http://10.66.55.44/
After clicking ‘Save’, power off/on the
HGT-100.
NB: When using DHCP, ensure that the PC connected to the PC-Port
is on the same network segment as the HGT-100, otherwise Internet
access from the PC will not be possible.
KX-HGT100 Configuration (7)
Username and Password:
Modifies the HTTP
Login User name
and Password from
default
If Idle Timeout expires, unit will need to be powered off/on to re-open HTTP port. (“Special” Setting)
KX-HGT100 Configuration (8)
Basic Settings:
Refer to next slide for
language parameters;
SIP Extension details and
password (Telephone
Number and SIP ID can
match)
SIP Proxy, Registrar and
Domain information.
For NCP Extension, enter
the IP address of the NCP
for all settings.
KX-HGT100 Configuration (9)
Basic Settings: (Example)
(Stand-Alone SIP Telephone configuration with Gamma SIP Account)
SIP Number,
Account and
password.
SIP Proxy,
Registrar and
Domain (IP or
DNS).
KX-HGT100 Configuration (11)
Advanced Settings:
RTP Port Range (Voice Traffic)
Codec Priority:
PCMA/U = G711A/U
G726-32 (N/A for TDA/NCP)
G729A
DTMF Type:
Inband/Outband(RFC2833)
SIP UDP Control port
Diffserv(ToS) field settings
One Time Caller Code either Permits or Denies CLIP sending on a per call basis,
depending on the “My Caller ID” setting of the HGT100.
KX-HGT100 Configuration (14)
Configuration File:
Basic Configurations can
be backed-up and/or
loaded via this screen.
This allows a dealer to
create a profile template
and then modify only a
small number of
parameters
(Number/Password etc)
KX-HGT100 Configuration (15)
Upgrade Firmware:
Firmware updates can
be managed easily
from this page.
Power off/on the unit
to complete the
upgrade.
KX-HGT100 Configuration (16)
Unit Maintenance:
Lan/PC Port.
Speed/Duplex Settings;
Auto Negotiate
100Mbps/Full Duplex
100Mbps/Half Duplex
10Mbps/Full Duplex
10Mbps/Half Duplex
Auto Sense is supported.
KX-HGT100 User Setting (1)
‘PROGRAM’ KEY
‘OK’ KEY
LCD DISPLAY
‘INFORMATION’ KEY
‘NAVI’ KEY
AUTO
HOLD
Message
Transfer
‘SP-Phone ‘Key
‘MUTE’ KEY
‘REDIAL’ KEY
SP-Phone, Hold
and Message Keys
have LED.
KX-HGT100 User Setting (2)
Keys used:
PROGRAM
Select
OK
1.
Save Speed Dial?
Enter No. 1
[OK]=YES
No. 1
[OK]=SET
0123456789
Saved in No. 1
How to access :-
Speed dial 0 ~ 9
AUTO
1
‘OFF-HOOK’
KX-HGT100 User Setting (3)
2.
Set Date + Time
Enter Year 2008
[OK]=YES
[OK]
Enter Month/Day
05/07
▲▼= AM/PM/24H
Enter Time
17:30PM
17:30
[OK]
[OK]
[OK]
3.
My Caller ID
(Show)
[OK]=YES
CLIR (Show/Hide)
OK
Select
Show/Hide
OK
KX-HGT100 User Setting (4)
4.
LCD contrast ?
[OK]=YES
- ██████
+
Select
[OK]=YES
4 STEPS
5.
Ringer Tone ?
Select
Ring 1 [OK]=YES
Ringer Tone ?
Ring 2 [OK]=YES
3 STYLES
6.
Ringer Volume ?
Ring 1 [OK]=YES
Ringer Volume [OK]
OFF - █████
+
4 Position + ‘OFF’
‘OFF’ = SP-Phone LED Flashes
Select
KX-HGT100 User Setting (5)
7.
Set Hold Music ?
(#01) [OK]=YES
OK
Select
#11 Settings (Inc ‘OFF’)
8.
KeyTone Volume ?
[OK]=YES
Keytone Volume
Select
OFF - ███ + [OK]
3 Settings (Inc ‘OFF’)
9.
Time AM/PM 24H
(AM)
[OK]=YES
OK
Select
AM/PM/24H
KX-HGT100 User Setting (6)
10.
Change Language ?
English
[OK]
Select
OK
Refer to
Slide #14
for
supported
languages
11.
STATIC IP
Set Network ?
(STATIC) [OK]=YES
Default GW
[OK]
192.168.000.001
Select
OK
Or
DHCP
Subnet Mask
[OK]
255.255.255.0
IP Address
[OK]
192.168.010.003
KX-HGT100 User Setting (7)
Select
INFORMATION
1
Own number
01234
2
Status
Normal
3
Network
STATIC
6
5
4
Default Gateway
192.168.000.001
Subnet Mask
255.255.255.0
IP Address
192.168.010.003
KX-HGT100 ‘Special’ setting (1)
‘Special’ Settings:
Factory Default:
To return the unit to it’s factory default settings, press
[Program] + [OK] + [Mute] and power-on the unit.
If successful, “Not Configured Web Setting” will be displayed in the LCD.
HTTP Port open:
To re-open the HTTP Port after initial setting or Idle time-out (default 30min)
[OK] + [Mute] and power-on the unit.
Firmware Roll-back:
To rollback the firmware to the previously installed version
[Program] + [Mute] and power-on the unit.