UV Lamp - SVECOM
Download
Report
Transcript UV Lamp - SVECOM
Welcome Acklands-Grainger
April 16, 2003
Technology
Applications
Advantage: VX500
Technology
Sensing
Technology
UV Lamp
Technology
UV Lamp
Technology
UV Lamp
Technology
UV Lamp
Technology
UV Lamp
Technology
+
-
UV Lamp
Technology
+
-
Positive
electrode
Negative
electrode
Technology
+
Positive
electrode
57.2 ppm
-
Negative
electrode
Technology
Lamp Choice
Technology
• Power of lamp measured in electron volts (eV)
• eV rating of lamp must be higher than eV potential
of compound (found in NIOSH guide) for
compound to be detected
Technology
Chemical Name
Benzene
Toluene
m-Xylene
Ethylbenzene
Ammonia
Methylene Chloride
Carbon monoxide
Oxygen
Water
IP (eV)
9.25
8.82
8.56
8.77
10.20
11.32
14.01
12.08
12.60
Detected with a Detected with
10.6 eV lamp
a 11.7 eV lamp
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
Technology
Selectivity
Technology
• PID’s are not selective in which compounds they
detect
• Apply the correct response factor to the reading
• Need to consider:
– What VOC’s am I likely to see?
– What of these has the lowest Permissible Exposure
Limit?
Applications
Applications
Petrochemical
• Benzene monitoring
• Personnel hygiene
monitoring
• Safety monitoring
applications
Applications
Fire Service/Hazmat
• Arson investigation
• Site assessment
• Perimeter monitoring
• Spill tracking
• Leak detection
Applications
Military & Commercial Aviation
• Fuel cell entry
• Safety monitoring
Applications
Environmental
• Remediation
• Soil sampling
Applications
Law Enforcement
• Drug raid teams
• First responder
• Domestic preparedness
Advantage: VX500
Advantage: VX500
The VX500 is completely compatible with the
DS1000 Docking Station
Dockability
Advantage: VX500
The VX500 can be
connected to the iTX
or any non-aspirated
Industrial Scientific
instrument for realtime multigas
monitoring with ppm
VOC, or can be used
in stand-alone
Flexibility
Advantage: VX500
• Accessible lamp
• Easy lamp cleaning
• Lamp conditioning module
• Duckbill pump filter
• Simple faceplate replacement
• Easy ionization chamber cleaning
Easy to Service
Advantage: VX500
• Continuous monitoring of benzene
• Cost effective
• Simple – same instrument
Benzene
Monitoring
Advantage: VX500
Rotating Dot Matrix
Easy-to-read dot matrix display
180 degrees
Display can beforrotated
easy reading while
hanging during perimeter
monitoring
Lithium ion battery delivers 18 hours of runtime
Runtime
Advantage: VX500
• Field input with iButton
• Snapshot Mode
• Expanded capacity
• (7500 data points or 1800
snapshots)
Datalogging
Flexibility
Advantage: VX500
Flow technology and compensation programming
minimizes the effect of humidity and
temperature extremes on the VX500s
performance
Humidity & Temperature
Performance
Advantage: VX500
Lamp
Sample draw range
Range
Resolution
Preprogrammed response
factors
Approvals
Weight
Size
10.6eV
100 feet
0 – 5000 ppm
0.1 ppm @ 0-99.9 ppm
1 ppm @ 100 – 5000 ppm
100 total with area for 5
favorites
UL, cUL, CENELEC
(ATEX) and Australia – EEx
ia IIC T4
25.6 ounces (726g)
10.0” x 3.0” x 2.1”
(253mm x 75mm x 53mm)
Resources
• VX500 Launch CD
• VX500 manual
• Catalog
• 1-800-DETECTS (1-800-338-3287)
• Local ISC District Manager