presentation
Download
Report
Transcript presentation
The special unit for special tasks
Installation possibilities
Private area
Industrial park
Special object
Technical specifications
•
•
•
•
•
•
•
Power supply voltage: 9-36 Vdc
Current: 200 mA
4 freely-configurable input channels
4 NC relay outputs
Remote outputs testing
250m sensor cable/input (max.)
Starting point is extendable (max. 500m) using
‘DC’ (non-sensitive) cable
• Radio interference- resistant metal housing
(IP65-rated)
• Programming via computer (RS485 protocol)
• 256 network address, in bus line used
• Operating temperature: -40 to +65 C
The sensorcable
The sensor cable core connection tube
4 freely-configurableinputchannels
• Vibration (sensor) cable
• Seismic sensor (optional)
• Frequency detector (not used)
• PIR sensor (not used)
Fence detection system
The fence sensor cable operation
Functioning of the system:
Because the cable is physically responsive to
the fence to which it is affixed, it senses any
abnormal movement/vibration of the fence.
If an intruder attempts to climb the fence , it
will move horizontally and vertically, and the
sensor cable will detect this movement.
The more sensor cable applied to a given
section of fence (depending on its
characteristics and condition), the more
precise the digital conversion of the received
analog signal – that’s why QuadroSense
generates fewer false alarms.
Sensor cable installation
Fence detection atwork
Use of an optional, intermediate 'DC' cable
between the QuadroSense central unit and
the sensor cable permits placement of the
sensor cable up to 500m away from the
central unit.
If the ‘DC’ cable is cut, QuadroSense
immediately generates an alarm signal.
Sawing and cutting detection
View and adjust two related parameters in
real-time mode:
• HF parameters
• To detect attempted sawing and/or
cutting of the sensor cable
• LF parameters
• To detect attempted climbing and/or
scaling of the fence
Seismic sensor
• Max. 12 sensors per channel
• Max. 15m diameter detection zone
per sensor
• Not visible after installation
Programming
All inputs are programmable by
computer (RS485 protocol) - it is possible
to fine-tune the system.
Installations world-wide
Hungary
Slovakia
Lithuania
Russia
Poland
Italy
Spain
France
Canada
Installation Option 1.
Installation Option 2.
Installation Option 3.
Installation Option 4.
Installation Option 5.
Easy and simple combinability
Easy and simple assimilation
Easy and simple integration
Detection zone
sensor cable
Thank you for your attention!
Contact details:
[email protected]
[email protected]
www.umirs.eu