Versa VM Machined Accent

Download Report

Transcript Versa VM Machined Accent

INSTALLATION INSTRUCTIONS
Versa VM Machined Accent
113018 C
IMPORTANT: Read all instructions before performing any work. To avoid
the risk of electric shock, turn off power before installing or
servicing luminaire.
WARNING:
Luminaire must be grounded in accordance with appropriate
codes. Failure to do so may result in serious injury.
Vertical Adjustment
Use 5/32” hex key
(provided) to adjust
knuckle.
Axial Adjustment
Use hand-tighten locking nut
to adjust axial rotation.
© 2012 Illumitex Inc. All rights reserved. The information in this document is subject to change without prior notice.
Illumitex Inc. | 5307 Industrial Oaks Blvd., Ste. 100 | Austin, TX 78735 USA | +1 512 279 5020 | www.illumitex.com
INSTALLATION INSTRUCTIONS
Versa VM Machined Accent
113018 C
IMPORTANT:
Read all instructions before
performing
any work. To avoid
Lumen Level Adjustment
Shroud
Attachment
the risk of electric shock, turn off power before installing or
servicing luminaire.
WARNING:
Luminaire must be grounded in accordance with appropriate
codes. Failure to do so may result in serious injury.
Adjustment ring
5/64” hex key
(provided)
Set fixture to desired lumen level by aligning
groove in adjustment ring with appropriate
groove in fixture body. Longer grooves in the
fixture body provide a higher lumen output.
Place shroud onto front of fixture and rotate to
desired orientation. Tighten (3) set screws with
5/64” hex key provided.
© 2012 Illumitex Inc. All rights reserved. The information in this document is subject to change without prior notice.
Illumitex Inc. | 5307 Industrial Oaks Blvd., Ste. 100 | Austin, TX 78735 USA | +1 512 279 5020 | www.illumitex.com
INSTALLATION INSTRUCTIONS
Versa VM Machined Accent
113018 C
IMPORTANT:
Read all instructions before
performing
any work. To avoid
Lens Replacement
Colored
Filter Installation
the risk of electric shock, turn off power before installing or
servicing luminaire.
Housing
WARNING:
Luminaire must be grounded in accordance with appropriate
codes. Failure to do so may result in serious injury.
Lens ring
Flat glass lens
(shipped installed
to fixture)
Colored filter
(ordered separately)
5/64” hex key
(provided)
22° Optic
36° Optic
(included)
(included)
Twist the lens ring counter-clockwise to remove
from fixture. Remove existing lens but do not
remove black silicone gasket. Select either the 22°
or 36° optic and place in front end of fixture with
flat surface against the black silicone gasket.
Replace lens ring, turning clockwise until tight.
Use 5/64” hex key to loosen (2) set screws on
fixture housing. Gently twist & pull to remove
housing from fixture body. Insert colored glass filter
inside of housing. Replace housing with colored
filter back onto fixture body with a gentle twisting
motion. Use 5/64” hex key to retighten (2) set
screws on fixture housing until snug. Do not overtighten set screws! (Note: Housing is easier to
remove and replace if lens ring and lens are
removed from fixture to eliminate pressure).
© 2012 Illumitex Inc. All rights reserved. The information in this document is subject to change without prior notice.
Illumitex Inc. | 5307 Industrial Oaks Blvd., Ste. 100 | Austin, TX 78735 USA | +1 512 279 5020 | www.illumitex.com
INSTALLATION INSTRUCTIONS
Versa VM Machined Accent
113018 C
IMPORTANT:
Read all instructions before performing any work. To avoid
Installation Instructions
the installing
risk ofVersa
electric
shock, turn off power before installing or
1. Ensure power is off before
VM fixture.
servicing
2. Versa VM fixture is intended
to be luminaire.
mounted on an Illumitex “VMT” mounting stake or junction box (provided by
others) which is UL listed
for low voltage
and wet
WARNING:
Luminaire
must
belocations.
grounded in accordance with appropriate
3. Wire fixture per instructions
listed
below. to do so may result in serious injury.
codes.
Failure
Low Voltage Cable Instructions
1. Low voltage cable connector (by others) or outdoor use, corrosion protected wire nuts (by others) to be used with
10 or 12-gauge supply cable (by others) and 18-gauge SPT-1W fixture cable supplied with the Versa VM fixture.
2. Supply cable to be laid on top of the ground, placed under "ground cover" (shallow burial, less than 6 inches deep),
or directly buried in accordance with the NEC.
3. Supply cable must be SPT-3W or suitable for wet locations, sunlight resistant and direct burial per UL 493 and sized
per UL 1838, and must be buried less than 6 inches deep. Minimum depth of 4 inches is recommended when
burying in lawns to prevent damage from aerators or other lawn equipment.
4. The 18-gauge cable provided with the fixture must be protected by routing in close proximity to the fixture or
secured to a building structure such as a house or a deck. 18 gauge fixture cable supplied with the Versa fixture
must be cut off so that it is connected to the low voltage cable connector or wire nuts within 6 inches of the fixture
or building structure.
5. When making an underground connection to the 10 or 12-gauge supply cable (not provided), the fixture cable must
not be buried more than 6 inches.
6. Connect supply cable to the terminals of the transformer (not provided) and turn ON.
7. If using a cable connector supplied by others, follow connector manufacturer instructions.
WARNINGS:
Mount the Versa VM fixture in or on non-combustible mounting surfaces only!
Risk of electrical shock. Install fixture a minimum of 10 feet from pools, spas & fountains!
NOTE:
This fixture is intended for installation in accordance with the National Electric Code and local code specifications.
Failure to adhere to these codes and instructions may result in serious injury and/or damage to fixture, voiding the
warranty. These instructions do no purport to cover all details or variations in equipment, nor to provide for every
possible contingency related to installation, operation, maintenance, or mounting. Should specific problems occur
that are not addressed by these instructions, contact your local sales representative or distributor for assistance.
Retain these instructions for future reference.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS:
Lighted fixture is hot. To reduce risk of injury to persons, turn fixture off or unplug and allow to cool before
adjusting or re-aiming.
© 2012 Illumitex Inc. All rights reserved. The information in this document is subject to change without prior notice.
Illumitex Inc. | 5307 Industrial Oaks Blvd., Ste. 100 | Austin, TX 78735 USA | +1 512 279 5020 | www.illumitex.com