Intelli-FLEX™ Intelligent Fence Mounted Cable Type Sensor
Download
Report
Transcript Intelli-FLEX™ Intelligent Fence Mounted Cable Type Sensor
ARITECH
Intelli-FLEX™
Intelligent Fence Mounted
Cable Type Sensor
A Technological Breakthrough
in Signal Processing for
Cable-Type Sensors
Introduction
Intelli-FLEX™
• Cable-type intrusion detection sensor
(Fence Mounted)
– outdoor and interior applications
• Provides an alarm if an intruder
– attempts to climb over the fence
– attempts to cut through the fence
– attempts to lift the fence fabric
– attempts to penetrate wall (indoor version)
Typical Configuration
Dual zone deployment
Vocabulary
Glossary of terms
• Zone
– The area or sector that is being monitored.
• Sensor cable
– The proprietary coaxial transducer cable mounted on
the fence.
• Non-sensitive cable
– RG59/u coaxial cable that connects the processor to
the sensitive cable.
• Processor
– Outdoor mounted electronics required to analyze the
sensor cable disturbance.
Equipment List
Intelli-FLEX™ System Elements
• Processor w/ enclosure and power
supply & battery charger
• Program Module
• Sensor Cable
• Non-sensitive Cable
• Splice Kit
• Terminator Kit
Theory of Operation
• Triboelectric Effect
– Minute movement (flexing) of the cable will
produce a transfer of charge between
conductors in the passive sensor cable.
This measurable signal is monitored at one
end of up to 1000 feet (300 m) of cable
Supervision Circuits
Sensor cable supervision
• Monitored by a small DC current
• Terminated by a 1M ohm resistor (EOL)
• If the cable is cut, shorted, or the
processor enclosure is tampered with, a
supervision alarm will be generated
• Hall Effect” board mounted magnetic
tamper switch.
Cable Splices
Terminator/Splice
Kits
• UV protected and
weather resistant
• Connect sensitive
cable to nonsensitive cable, or
sensitive cable to
sensitive cable.
UPPERHALFSHELL
ENDCAP
TERMINAL BLOCK
LOWERHALFSHELL
Theory of Operation
Processor
• Continually evaluates electrical signals
generated by the sensor cable, and
converts the information to a digital
format.
• Through “Adaptive Algorithms”, the
processor will alarm if an intruders is
trying to
– Cut the fence fabric.
– Climb the fence.
– Lift the fence fabric.
Key Hardware Features
“Standard” Dual Zone Processor
Microprocessor - Based
Backward Compatibility
Low Power Consumption
Full Lightning Protection
Handy Programming Module
Optional Weather Station
Low Power Consumption
Only 70mA of current required for
normal two zone operation
Small internal Gel Cel (.8AH) battery
provides minimum 8 hour backup
State of the Art Lightning
Protection
Gas discharge tubes and transzorbs
on all inputs and outputs provide
maximum protection against
lightning
Backward Compatibility
Intelli-FLEX uses existing E-Flex
Cable, Splices, Gate Kits and Tie
Wraps
Microprocessor Based
A powerful Motorola 68HC11 Series
processor resides within each IntelliFLEX system
Contains onboard A/D converters,
memory and I/O dedicated to
analyzing fence disturbance signals
Enhanced Features
Separate Threshold Adjustments for
Cut and Climb for each zone
Extremely important in lowering
nuisance alarm in demanding
situations
“Learn Fence” Mode
Internal Automatic Self Test
Key Software Features
Adaptive Algorithms™
Ambient Compensation
Common Mode Rejection
“Learn Fence” Mode
Separate Cut & Climb Thresholds
Cipher Protected Adjustments
Optional Built-in Transponder
Theory of Operation
Processor (continued)
• Operates on 20VAC or 12VDC.
• Back-up battery provides over 8 hours
of operation during power failures.
• Operationally tested from -30 o C to
+70 o C.
Adaptive Algorithms™
Sophisticated software code written
to change or modify system
parameters as new information is
received
Ambient Compensation
Statistical analysis of digitized
analog signals identifying properties
inherent in wind & rain as they differ
from cut & climb
Provides a “Dynamic Threshold” as
weather events build, without
sacrificing sensor performance or
detection
Common Mode Rejection
An event “qualifier” that compares
identical weather effects on
adjacent zones to verify ambient
compensation measures
Audio Option
Optional audio plug in board allows
selection and monitoring of sensor
cable signals.
Provides “Listen-in” capability
On-board line amplifier
Remotely switchable - Zone 1 or 2
Weather Station Option
Enclosure mounted weather sensor
provides simple rain and wind
verification to the processor via
A/D converter
Multiplexer Option
Mux version of the Intelli-FLEX
board provides data communication
interface within the signal processor
eliminating the requirement for
outboard transponders or
multiplexers
Theory of Operations
Options (continued)
• Weather Station
– Provides weather data so the processor
may make intelligent decisions.
• Self Test Terminator
– Provides a permanent and convenient way
to test zones remotely. No external power
or wiring is required.
Preparing for Installation
Installation Planning
•
•
•
•
Perimeter of installation
Perimeter structure
Mounting the processors
Monitoring and power wiring.
Preparing for Installation
Site Survey
• Should be conducted before installing
any system hardware
• To ensure optimum performance...
– Mounting surface should be as stable as
possible.
– Fences must be cleared of vegetation and
any other objects that disturb the structure.
– A good earth ground should be achieved for
the sensor processor.
Preparing for Installation
Site Survey (continued)
• Fence condition is critical to the
trouble-free and efficient operation of
the Intelli-FLEX sensor.
– All fence framework should meet or exceed
minimum specifications outlined in the
installation manual.
Preparing for Installation
Determining a List of Materials
• The Intelli-FLEX™ sensor system is
supplied in kits for installation
convenience.
– Single zone kits
– Dual zone kits
• All Intelli-FLEX hardware components
may be purchased individually.
• Options enhance the overall
effectiveness of secure facilities.
Typical Configuration
Processor installation (single zone)
SENSOR
CABLE
TIE
WRAP
SKJ-8
(JUNCTION)
NON-SENSITIVE
CABLE
PROCESSOR
SK-8
(TERMINATOR)
Installation
Junction devices
• Moisture proof
• Connects sensor cable to non-sensitive
feed cable, or sensor cable to sensor
cable, and holds termination
resistor/card.
UPPERHALFSHELL
UPPERHALFSHELL
ENDCAP
1M RESISTOR
TERMINAL BLOCK
LOWERHALFSHELL
TERMINAL BLOCK
LOWERHALFSHELL
Installation
Sensor cable
• Mounted directly to the fence
• May be mounted in conduit
• Secured by UV protected tie wraps
every 12 inches (.3m)
INCORRECT
CORRECT
Installation
Sensor Cable (continued)
• Fences >8 feet (2.5 m) in height should
have double passes.
1/3 HIEGHT
SK-8
(TERMINATOR)
1/3 HIEGHT
SK-8
(JUNCTION)
1/3 HIEGHT
FENCES OVER 8 FEET (2.5 METERS) HIGH MUST BE
DOUBLE-PASSED FOR OPTIMUM DETECTION
Installation
Sensor Cable (continued)
• Fence at corner posts need additional
sensitivity due to the rigidness of the
fence.
SENSOR CABLE AT 1/2 FENCE HEIGHT
LOOP
1/4 FENCE
HEIGHT
1/4 FENCE
HEIGHT
Installation
Gates
• Protected gates
SK-8
RG-59 IN PVC CONDUIT
18" (46 CM) UNDERGROUND
Installation
Gates (continued)
• Unprotected gates
SK-8
RG-59 IN PVC CONDUIT
SK-8
18" (46 CM) UNDERGROUND
Installation
Gates (continued)
• Protected sliding gates may use EJ-8
Quick Disconnect Assembly
CABLETIE
EJ-8 FEMALE
FEMALE
CAP
SK-8
CABLETIE
HOSECLAMP
MALECAP
EJ-8 MALE
SK-8
Installation
Remote Self Test
Remote Test Option
• Generator board (no local power req’d)
TB2
END
CAP
Circuit Card
Calibration
Configuration Module
Calibration
Program Module for Setup& Config
Calibration
Program Module Modes
• Monitor mode
– Operator can monitor the detection
activity for the indicated zone ant threat
scenario.
• Configure mode
– Operator can view and change the
Operating Parameters, and Functional
Parameters while in this mode. No
alarms are reported in this mode.
Calibration
Factory default Threat Assessment parameter settings
Zone Threat
Operation
Factory Setting
1
Cut
Time Window
30 seconds
1
Cut
Threshold
5
1
Cut
Cut Count
4
1
Climb
Time Window
20 seconds
1
Climb
Threshold
5
1
Climb
Climb Time
2 seconds
2
Cut
Time Window
30 seconds
2
Cut
Threshold
5
2
Cut
Cut Count
4
2
Climb
Time Window
20 seconds
2
Climb
Threshold
5
2
Climb
Climb Time
2 seconds