PowerPoint Style Guide & Templates - Eaton

Download Report

Transcript PowerPoint Style Guide & Templates - Eaton

Eaton 9E UPS
New Product Introduction
October 2011
© 2011 Eaton Corporation. All rights reserved.
9E UPS Overview
Product Snapshot
Power Rating: 20, 30, 40, 60 kVA
Topology: Double-Conversion with High
Efficiency Mode
Input/Output Voltage: 208/208 or 220/220
Frequency: 50/60 Hz
Configuration: Tower
Internal Batteries: 5-21 minutes
© 2011 Eaton Corporation. All rights reserved.
2
2
What is the 9E UPS?
The 9E is the Class Leader!
• Delivering superior power protection for
expanding loads in space-constrained data
centers, the 9E provides Total Cost of Ownership
through:
• 98% Efficiency
• Internal batteries
• Smallest footprint – 35% smaller than
competition!
© 2011 Eaton Corporation. All rights reserved.
3
3
98% Energy Efficiency
Lowering costs in every comparison!
9E High-Eff
Legacy UPS
98%
88%
Efficiency
Annual Savings
$10,532
Lifetime Savings
$126,384
9E Double
Conversion Eff.
Legacy UPS
92%
88%
Efficiency
Annual Savings
$4,487
Lifetime Savings
$53,844
* Using 60KVA/48KW 100% load, DCiE 60%, $0.10 kW/hr,$12.00 kW demand,
3% discount rate, 12 year life
© 2011 Eaton Corporation. All rights reserved.
4
4
9E – Internal Batteries
The 9E is the only UPS to offer internal
batteries up to 60 kVA! This saves significant
space compared to added external battery cabinets
and makes the 9E a simple choice for any location
or facility
• Pre-wired and installed batteries simplifies setup
• No additional cabinets needed, a complete UPS
in one cabinet
kVA
Minutes
20
21
30
12
40
10
60
5
© 2011 Eaton Corporation. All rights reserved.
5
5
9E Compact Footprint
60 kVA Configurations
Product
Dimensions
(inches, W x D x H)
Footprint
(square feet)
Runtime
(min) 60 kVA
9E
23.6
31.5
74.9
5.2
5
Competitor A
45.3
30
72
9.4
8
Competitor B
48
35.5
81.5
11.8
7
Competitor C
56.8
38
78.5
15
4
© 2011 Eaton Corporation. All rights reserved.
Up to a 35%
smaller footprint!
6
6
9E Easy Installation
The 9E was designed with reduced installation
costs in mind, further reducing capital
expenditures by minimizing installation time.
• Pre-wired internal batteries, only facility connections
are needed
• Integrated “ship flat” wiring conduit plate and
doghouse
• Optimized angled connections reduce bending
radius of input and output wiring
• Clean clear wiring terminal block access for easy
connections
• Integrated wheels facilitate easy movement to
final location
• Eaton start up is optional
© 2011 Eaton Corporation. All rights reserved.
7
7
9E Easy Serviceability
The 9E was designed to
reduce mean-time-to-repair to less
than 30 minutes!
• Slide Out Trays
• New Eaton Service Tool
• Optional On-board Maintenance
Bypass rotary switch allows replacement
of power modules, control board, and
display
© 2011 Eaton Corporation. All rights reserved.
8
8
9E Total Cost of Ownership
Savings Metric
Potential
9E Savings
Energy
$71,292
Space
$11,880
Installation,
Maintenance,
Freight
$2000
Total Potential
Lifetime Savings
$85,000+
* Using the 60KVA/48 KW compared to a 91% efficient UPS with a
footprint of 11.8 sq ft or
© 2011 Eaton Corporation. All rights reserved.
9
9
Technical Specifications
Power Factor
Input Voltage Range
Input Current Distortion
Output Voltage Regulation
Load Power Factor Range
Number of Strings
Number of Batteries per String
.8
-15%, +20%
5% THD
+-1% static
+-5% dynamic
.8 leading to .8 lagging
6
18
12V, 9 Ah
110% for 10 min
Overload Capability
125% for 30s
150% for 40 ms
Operating Temperature
0-30 C
© 2011 Eaton Corporation. All rights reserved.
10
10
Intelligent Power Manager
• Supervisory Software
• Free for Monitoring up to 10 devices
• Delivers a global view of power devices across the network
from any PC with an Internet browser
• Enables single, Web-based interface for remote monitoring
and management of:
• Eaton® and other manufacturers’ UPSs
• Environmental sensors
• ePDU® products and more
© 2011 Eaton Corporation. All rights reserved.
11
11
9E Accessories
• Extended Battery Cabinet Give the 9E flexible runtime options,
seamlessly paired cabinet to 9E UPS
• Integrated Accessory Cabinet
• Several configurations available to:
• Parallel tie and maintenance bypass
• Maintenance bypass
• Distribution with 42-pole panel board
• Integrated Transformer Cabinet
• Houses transformer configurations to adjust input/output voltages
to meet location requirements (480/208V, 480/480V)
• Wall-mount Bypass Panel
• Saves even more floor space and available in two configurations:
• Bypass
• Bypass with 36-pole distribution
© 2011 Eaton Corporation. All rights reserved.
12
12
Learn More
Learn more today by visiting www.eaton.com/9E
© 2011 Eaton Corporation. All rights reserved.
13
13
© 2011 Eaton Corporation. All rights reserved.
14
14