Organic Qualitative Analysis
Download
Report
Transcript Organic Qualitative Analysis
Organic Qualitative Analysis
Determination of functional groups present in an
unknown organic compound by their
characteristic chemical reactions.
You will be introduced to qualitative tests that
indicate the presence (or absence if negative) of
aryl and alkyl halides, unsaturated compounds
(alkenes and alkynes), aromatics, alcohols and
alkanes.
Solubility Tests (In water or sulfuric acid)
Carefully place 1 mL of the solvent (water or conc. H2SO4) in a test tube.
Add a drop of your unknown, and gently tap the test tube and swirl the solution.
Solubility in Water: Mixing of the solutions indicates solubility.
Separation into two layers indicates insolubility.
Water solubility suggests a relatively low M.W. (< C4) alcohol.
Solubility in conc. H2SO4: Sulfuric acid will solubilize alkenes
(often with color change).
It will not solubilize alkanes, alkyl halides or aromatics.
Test for Unsaturation - Alkenes
Bromine/CH2Cl2 Test.
Add 2 drops of liquid unknown to 1 mL of methylene chloride (CH2Cl2). Add the solution of Br2 in CH2Cl2
solution, dropwise, while shaking the test tube, until the bromine color is no longer discharged.
A positive test for an alkene is indicated, if the bromine color is initially discharged on adding
the Br2, but a permanent bromine color persists after the addition of ~ 5 drops of the Br 2
solution (when all of the alkene has reacted).
Baeyer (KMnO4) Test.
Add 2 drops of liquid unknown to 2 mL of water or CH2Cl2 (depending on the solubility of the alkene) in a test
tube. Slowly add a 1% KMnO4 solution dropwise, with shaking, to the unknown solution.
A positive test for an alkene is indicated, if the purple color of the KMnO 4 solution changes to a
brown precipitate of MnO2 , usually within a minute.
Test for Unsaturation Aromatic compounds or Polyalkenes
Ignition Test
Place a small amount of the compound on a spatula and place in a hot Bunsen flame.
A sooty yellow flame will indicate an aromatic compound or one with a high
degree of unsaturation
Tests for an Alcohol
Chromic Acid Test
Add 1 drop of liquid unknown to 1 mL of acetone in a test tube. Add 1 drop of chromic acid reagent.
A change from yellow-orange chromic acid to green Cr2O3 (on reduction of the chromium(VI)
to chromium(III))indicates a primary or secondary alcohol.
Tests for an Alcohol
Cloudiness indicates a positive test for secondary or tertiary alcohol.
Alkyl halide tests
Beilstein test.
A copper wire is cleaned by heating in a Bunsen burner flame and dipped into a sample of the
unknown. The copper wire is then placed in the Bunsen burner flame again.
A green flame indicates the presence of a halogen (Cl, Br or I) in the unknown.
AgNO3 Test.
Add 1 drop of an unknown liquid to 2 mL of a 2% ethanolic AgNO3 solution. Allow the solution
to sit for five minutes.
A precipitate formed (within 5 min) indicates a tertiary alkyl halide.
If no precipitate forms in 5 min, heat in a hot (~ 100o) water bath.
A precipitate formed after heating indicates a primary or secondary alkyl halide.
Aromatic halides are generally unreactive.
Alkyl halide tests
NaI in Acetone (distinguishes tertiary, sec-and primary-alkyl-Br and –Cl and alkyl-I)
Add 2 mL of 15% NaI in acetone to 4 drops of the unknown in a clean dry test tube. Shake the
tube well to ensure mixing of the alkyl halide and the acetone solution.
Immediate precipitate (within ~ 3 minutes) indicates tertiary alkyl chloride or alkyl
bromide.
If no precipitate forms in 5 minutes, place tube in < 50oC water bath. After another minute at
50oC., cool to room temperature (Acetone boils at ~ 50 oC)
A precipitate after heating indicates primary or secondary alkyl chloride or bromide.
A clear solution indicates an alkyl iodide.
Infrared Spectrum and Refractive Index
When you have completed your qualitative analysis
tests, measure the refractive index of your unknown.
Correct the value observed at room temperature to
a corresponding nD20 value.
Record an IR spectrum of you unknown.
This is the Qualitative Analysis lab, and your lab
report should reflect this. Irrespective of the
information obtained from IR and refractive index,
your report should indicate the evidence obtained by
qualitative analysis (positive and negative) that
supports your identification.