Troubleshoot Battery to Panel Troubleshoot Panel to Light
Download
Report
Transcript Troubleshoot Battery to Panel Troubleshoot Panel to Light
Chapter 7
Basic Troubleshooting
and
Repair Procedures
MElec-Ch7 - 1
Overview
• Tools Needed
• Circuit Troubleshooting
• Electrical Interference
MElec-Ch7 - 2
Tools Needed
•
•
•
•
•
Multimeters
Wiring Tools
Miscellaneous Tools
Do-It-Yourself Test Tools
Commercial Testers
MElec-Ch7 - 3
Multimeter
• Required features in a boat’s multimeter
Measure up to 50 VDC
• DC voltages either 6, 12 and sometimes 24
Measure up to 250 VAC
• AC voltages either 120 or 240
Measure resistance or continuity
• Audible continuity checker is desirable
• Desirable features
Measure AC and DC current up to 10 amps
Entry level measure current to approx. 250 mA
MElec-Ch7 - 4
Analog Multimeter
• Advantage - Low cost
• Disadvantages
Difficult to read measurement value
Have to start at max value and work way down
MElec-Ch7 - 5
Digital Multimeter
• Advantages
Easy to read measurement value
More accurate readout
• Disadvantages
Have to start at max value and work way
down
Cost
MElec-Ch7 - 6
Auto-Ranging Multimeter
• Advantage
Only have to select function (not range)
• DC voltage, DC current, AC voltage or resistance
• Disadvantage - cost
MElec-Ch7 - 7
Wiring Tools
• Wire Cutter – Diagonal Cutter
5 or 6” overall
Plastic cushion grip
• Wire Stripper
Don’t use knife
Are dedicated tools
Most used – Combination Cut/Strip/Crimp Tool
• Not to be used as crimp tool
• Wire cutters at tip not effective
MElec-Ch7 - 8
Wire Cutters / Wire Strippers
MElec-Ch7 - 9
Wiring Tools - 2
• Ratcheting crimp tool required by ABYC
Covered in Chapter 2
Expensive compared to combination tool
• Soldering gun
Normally boat wiring is NOT soldered
• Done with crimp on terminals and butt spices
Required for some coax connectors
Recommend dual 100/140 watt
With appropriate tip will cut lines and fuse ends
MElec-Ch7 - 10
Crimp Tool / Soldering Gun
MElec-Ch7 - 11
Miscellaneous Tools
• Pliers
To hold objects
• Not a substitute for a wrench
Types
• Slip joint
• Needle nose
• 5” or 6” overall with plastic cushioned grips
• Wrench (for electrical work)
Adjustable 6”
MElec-Ch7 - 12
Pliers / Adjustable Wrench
MElec-Ch7 - 13
Screwdrivers
• Blade
3/16” blade with 4” shaft
1/4” blade with 4” shaft
• Phillips
#1 with 4” shaft
#2 with 4” shaft
• Small
1/8” blade with approx. 2” shaft
#0 Phillips with approx. 2” shaft
MElec-Ch7 - 14
Screwdrivers
MElec-Ch7 - 15
Circuit Trouble-Shooting
•
•
•
•
•
•
Batteries
Alternators
Battery Chargers
Boat Lighting System
Boat DC Electronic Systems
Boat AC Circuits
MElec-Ch7 - 16
Battery Testing
•
•
•
•
Hydrometer
Open-Circuit Voltage
Load Test
Three-Minute Charge
MElec-Ch7 - 17
Hydrometer
• Hydrometer – best tester of flooded-cell
Measures Specific Gravity
Chapter 3, Table 5
Specific Gravity
100
% charge
1.265
75
% charge
1.225
50
% charge
1.190
25
% charge
1.155
Discharged
1.120
MElec-Ch7 - 18
Open-Circuit Voltage
• For Maintenance Free, Gel & AGM batteries
When you can’t use a hydrometer
• Battery should rest for 24 hours, or
discharge with a large light bulb for a few
minutes
• Chapter 3, Table 5
Voltage
Flooded
Gel
AGM
100
% charge
12.65
12.90
12.85
75
% charge
12.4
12.65
12.6
50
% charge
12.2
12.35
12.3
25
% charge
12.0
12.0
12.0
Discharged
11.8
11.8
11.8
MElec-Ch7 - 19
Specific Gravity & Voltages
100 % charge
75 % charge
50 % charge
25 % charge
Discharged
Specific Gravity
(Flooded Cell @ 80 F)
Flooded Cell
Voltage
Gelled Cell
Voltage
AGM
Voltage
1.265
1.225
1.190
1.155
1.120
12.6 to 12.7
12.4
12.2
12.0
11.8
12.85 to 12.95
12.65
12.35
12.0
11.8
12.8 to 12.9
12.6
12.3
12.0
11.8
14.2 to 14.4
14.2 to 14.4
13.2 to 13.6
15.0 to 16.0
13.8 to 14.1
13.5 to 13.8
13.2 to 13.5
Do NOT Equalize
14.4 to 14.6
14.1 to 14.4
13.2 to 13.5
Do NOT Equalize
Charging voltage @ 80º F
Bulk
Acceptance
Float
Equilization
-
Chapter 3 Table 3-5
MElec-Ch7 - 20
Load Test
• Hydrometer and open-circuit voltage do not
indicate ability to provide current under
load
• Prevent engine from starting
Operate starter motor for approx 15 sec
Monitor battery voltage after 5 sec
• If voltage is over 10.5 VDC – Good Battery
• If voltage is under 10.5 VDC – Bad Battery
Replace battery
MElec-Ch7 - 21
Three-Minute Charge Test
• Actually takes six (6) minutes
• Charge battery at 40A for six minutes
• Measure voltage (at battery) with charger on
• If voltage under 15.5 VDC – Battery is good
• If voltage is over 15.5 VDC – Battery is bad
Not accepting charge
Is sulfated
Replace battery
MElec-Ch7 - 22
Alternator Testing
• Drive Belt
• Quick Test
• Alternator Electrical Connections
MElec-Ch7 - 23
Drive Belt & Quick Test
• Drive belt
Loose belt if “squealing” when engine started
Belt depression when pressed at midpoint
• Normal (correct tightness) is only 3/8” to ½”
• Over ½” is too loose, tighten belt
• Quick test with engine & battery charger off
Measure (battery) voltage at alternator
Start engine and measure voltage at alternator
• Alternator working if voltage increases
• Alternator not working if voltage constant
MElec-Ch7 - 24
Alternator Electrical Connections
To check wiring between alternator & battery
• First discharge battery for five minutes
• Then start engine & check for high resistance
connection between alternator & battery
• Voltage drop over 0.5 VDC needs to be fixed;
or over 1.0 VDC if there are charging diodes
Check both positive and negative circuit
Clean and tighten the bad connection
If you find a bad wire, replace it
MElec-Ch7 - 25
Battery Charger Testing
• Alternator vs Battery Charger
• Quick Test
• Troubleshooting
MElec-Ch7 - 26
Alternator vs Charger & Quick Test
• Alternator vs Battery Charger
Batteries charged by alternator
Batteries not charged by battery charger
• Defective battery charger; see Troubleshooting
• Quick test with engine & charger off
Measure (battery) voltage at battery charger
Turn on battery charger and measure voltage
• Battery charger working if voltage increases
• Battery charger not working if voltage constant
MElec-Ch7 - 27
Troubleshooting
• If Charger not working, check the AC input
Troubleshoot like AC Circuit, covered later
• If there is AC input, check for a blown fuse
Replace blown fuse ONCE
If fuse blows a 2nd time
• Disconnect wire going to battery and
install another fuse, then turn charger on
• If fuse blows again, have defective charger
• If fuse does NOT blow, measure DC voltage
– Should be between 13 and 16 VDC
MElec-Ch7 - 28
Troubleshooting - 2
• Turn Charger “Off”
• Disconnect charger positive wire at battery
Tape it to prevent wire shorting to ground
• Reconnect positive wire at charger
• Turn “On”, if fuse blows have short in wire
• If fuse does not blow, may have high resistance
connection between charger and battery
Troubleshoot wiring like you would for alternator
MElec-Ch7 - 29
Boat Lighting System
• Boat light inoperative
First replace bulb with known good bulb
Alternate test of suspect bulb
• Check continuity of filament
–Good bulb will have continuity
or low resistance
–Bad bulb will indicate no continuity
or infinite resistance
If good bulb does not work
• Need to troubleshoot lighting circuit
MElec-Ch7 - 30
Lighting Troubleshooting
• Need a logical sequence
• First check circuit breakers and switches
• Then isolate to battery to power panel
or
• Power panel to light
MElec-Ch7 - 31
Boat Light Inoperative
Replace / Check
Bulb
A
Light
Working
?
Yes
Stop
NO
Power
to Panel
?
NO
Troubleshoot
Panel to Light
NO
Turn
Battery
Switch On
A
Troubleshoot
Battery to Panel
Yes
DC
Main On
?
Yes
Battery
Switch On
?
Yes
NO
Turn DC
Main On
A
MElec-Ch7 - 32
Battery to Power Panel
No DC at battery side of DC main breaker
• Check/replace large fuse at battery
Use multimeter
• Check/clean/tighten wiring
Battery to battery fuse
Batter fuse to power panel
MElec-Ch7 - 33
Power Panel to Light
Have DC at load side of branch circuit breaker
• Check/clean/tighten wiring at branch breaker
• Check/clean corrosion at light socket
Use CRC QD Electronic Cleaner or equivalent
• Check/replace in-line fuse near light
• Check/replace switch in light
• Check wiring with temporary wires from
branch circuit breaker to light fixture
MElec-Ch7 - 34
Boat DC Electronic Systems
• 90% of equipment problems is lack of DC
or bad corroded cable connections
• First check for power to equipment
If there is power
• Check for blown fuse
• If fuse is good, there is an equipment problem
• Then check/clean cable connections
Use CRC QD Electronic Cleaner or equivalent
• Lastly troubleshoot like a lighting system
Previously covered
MElec-Ch7 - 35
Boat AC Circuits
• Testing
• Troubleshooting
MElec-Ch7 - 36
Testing AC Circuits
• Shore power polarity
Verify correct with Reverse Polarity Indicator
• Outlets
When first installed and once a year
Verify with AC Outlet Tester
• GFCI outlets
When first installed and once a year
Insert AC Outlet Tester
• Press “Test” – tester lights should go “Off”
• Press “Reset” – tester lights should go “On”
MElec-Ch7 - 37
Testing Hard Wired Appliances
• Turn on appropriate branch circuit breaker
and
• Appliance “On” switch
• Appliance should work
or
• Expose the AC terminal strip
Use multimeter
Check for AC voltage and polarity
• If have AC input and won’t work = Defective
MElec-Ch7 - 38
Troubleshooting AC Circuits
• Need logical sequence
• First check circuit breakers and switches
• Then isolate to dock to power panel
or
• Power panel to outlet or appliance
MElec-Ch7 - 39
AC Troubleshooting
Start
A
Power
to Panel
?
NO
Reset
Service
Breaker
A
Troubleshoot
Dock to Panel
Yes
AC
Main On
?
Yes
Service
Breaker Tripped
Yes
?
NO
NO
Turn AC
Main On
A
Troubleshoot
Panel to
Outlet / Appliance
MElec-Ch7 - 40
Dock to Power Panel
No AC at line side of AC main circuit breaker
• Check/reset dockside circuit breaker
• Check service cord
Use adapters and AC Outlet Tester
Power at dockside outlet?
Power at boat end of cable?
• Check/clean/tighten connectors and wiring
Disconnect AC power before working on AC
Use CRC QD Electronic Cleaner on contacts
MElec-Ch7 - 41
Power Panel to Outlet/Appliance
Have AC at load side of branch circuit breaker
•
•
•
•
Reset GFCI outlet
Disconnect AC power before working
Check/clean/tighten wiring at breaker
Check/clean/tighten wiring at
outlet/appliance
• Check wiring with temporary wires from
branch circuit breaker to outlet/appliance
MElec-Ch7 - 42
Summary – Circuit Troubleshooting
DC
•
•
•
•
•
•
Battery tests: Voltage, Load and 3-minute charge
Alternator tests: Drive belt, quick test and wiring
Battery Charger: Quick test, AC power and wiring
Inoperative lights: Bulb, bulb contacts and wiring
DC electronics: Verify DC power & clean contacts
DC wiring: Start at power panel and isolate
AC
• Test outlets yearly
• AC appliances: Verify AC power and check wiring
• AC wiring: Start at power panel and isolate
MElec-Ch7 - 43
Electrical Interference
•
•
•
•
•
Introduction
Sources of Interference
Locating Interference Sources
Interference Suppression
Mitigation Techniques
MElec-Ch7 - 44
Introduction
• Causes and Effects
Caused by rapid on/off current switching
Radiated through air
Conducted though wiring
Degrades high sensitivity electronic equipment
• Noise Layers
Usually have interference from several sources
Remove/reduce till acceptable
Difficult to identify stronger interference
MElec-Ch7 - 45
Sources of Interference
•
•
•
•
•
•
•
•
•
Ignition Systems
Charging Systems
Voltage Regulators
Electric Motors
Gauges and Instruments
Propeller Shaft(s)
Video Displays
Electronic Equipment
Fluorescent Lights
MElec-Ch7 - 46
Identification by Sound
• Ignition
Popping Sound related to engine speed
• Alternator
High-pitched musical whine
related to engine speed
• Voltage Regulator
Intermittent rasping sound
• Electric Motor
Hissing sound or whine
MElec-Ch7 - 47
Locating Sources
• What is Different?
• What is On?
• How is interference getting into equipment
Radiated?
Conductive?
• Pigtail Check (with bypass capacitor)
• Radio Noise “Sniffer”
MElec-Ch7 - 48
Interference Suppression
At source of interference
• Approaches
Repair or replace faulty equipment
Shielding to confine interference
Special-purpose components
to reduce interference
MElec-Ch7 - 49
General Suppression
• Replace/repair faulty equipment
• Correct defective wiring
Bonding straps still connected?
Check wiring for loose connections
• Re-run wiring
Separate power and signal wires/cables
Dress regulator field wire close to the alternator
• Shielding
Wires
Compartments with grounded copper screen
MElec-Ch7 - 50
Ignition System
• Primary
Shield ignition switch wiring
• Ground shield at engine (only)
Ground case of ignition coil
Install 0.1 µf coaxial capacitor
• in positive wire at coil
Install 0.005 µf disc ceramic capacitor
• at negative terminal of coil
• rated at 1,000 volts
Replace and adjust breaker points
Select and replace capacitor
MElec-Ch7 - 51
Ignition System – cont’d
• Secondary
Install resistor spark plugs
– Install resistor cable (between
distributor and spark plugs)
– Can be used together if needed
MElec-Ch7 - 52
Alternator
• If output less than 50 Amps, add a
0.5 µf coaxial capacitor at output terminal
• If over 50 Amps add a low-pass filter or inline choke at the output terminal
• Never bypass the alternator field
MElec-Ch7 - 53
Charger / Voltage Regulator
Battery charger
• Install near battery and away from electronics
• Suppression built in by manufacturer
• Home-made copper wire shield
Voltage regulator
• May be built in to alternator
• If external
Mount close to alternator
Consider shielding field wire (ground both ends)
MElec-Ch7 - 54
Electric Motors
• Well seated brushes
• By-pass with 0.25 to 0.5 µf capacitor
• Ground housing
MElec-Ch7 - 55
Gauges and Instruments
Gauges and instruments
• Bypass with 0.25 to 0.5 µf 200 volt capacitor
• Some may stop working when bypassed
Electric tachometers
• Don’t bypass (it will stop working)
• Shield wire and ground both ends
MElec-Ch7 - 56
Propeller Hash
Shaft Hash
– Indicates stray current or galvanic current problem
• If possible fix problem
– Best to ground the shaft with carbon brushes
– Fixes the symptom, not the problem
MElec-Ch7 - 57
Electronic Equipment
• All electronics and appliances
should be FCC Type Approved
Part 15 B of the FCC Rules
Look for decal/label
• Europe has a tougher RFI standard “CE”
Look for decal/label
MElec-Ch7 - 58
Mitigation Techniques
At equipment being interfered with
• Approaches
Shielding against radiated interference
Filtering against conductive interference
• Capacitors (or condensers)
• Chokes (or inductors)
MElec-Ch7 - 59
Shielding and Capacitors
• Shielding for radiative interference
• Capacitor (or condenser)
For conductive interference
Provide low reactance to AC
Placed across (parallel) input power terminals
Bypass undesirable AC noise to ground
MElec-Ch7 - 60
Chokes (Inductors)
• Choke (or inductor)
For conductive interference
Provides high reactance to AC
Placed in series with power wires
• Types of RF chokes
In-Line
Snap-On
Ferrite Data-Line
MElec-Ch7 - 61
Steps
• Ground metal case
• Bypass DC leads
• Bypass and shunt DC leads
• Add choke (in series with DC leads)
• Shield (and ground shield)
MElec-Ch7 - 62
TV Conductive Interference
• Turn AC outlet “Off”
• Install 0.01 µF (micro farad) disc ceramic
capacitor across hot and neutral terminals
Keep leads as short as possible
• Install snap-on choke in power cord
5 turns, left to right, on one side or core
Followed by 5 turns, left to right, on other side
MElec-Ch7 - 63
Summary - Interference
• Locating source
By its sound
What is different?
What is on?
By use of “sniffer”
• Interference suppression (at source of interference)
Equipment repair
Specific at equipment
Shielding of equipment
MElec-Ch7 - 64
Summary – Interference - 2
• New electronics and appliances should
be FCC and/or CE Type Approved
• Mitigation Techniques (at interfered-with equipment)
Shielding
Filtering