Options - MTE - Meter Test Equipment
Download
Report
Transcript Options - MTE - Meter Test Equipment
MTE´s Portable
Product Portfolio
Page 1
March
April 2011
2012
MTE Portables
Page 2
March 2012
K 2006
3-phase Comparator
30 V … 500 V
1 mA … 160 A
Accuracy 0.01%
15 Hz - 70 Hz
Measurements of:
voltage, current, active, reactive
and apparent power, energy,
frequency, power factor, error
measurement and harmonic
analysis
DC reference voltage input
Options:
CAMCAL® Software
CALSOFT Software
Page 3
March 2012
PRS 400.3
3-phase portable Reference Standard
0 V … 520 V (phase-neutral)
1 mA … 120 A direct connections
Clamp-on CTs:
100A 1.000A FLEX 3000
up to 3.000A / Hot sticks for
measurement on high voltage
potential
Vector diagram, harmonics
spectrum, wave form and rotary
field display
Burden measurement and ratio
tests of CT’s and PT’s
Transducer test
Accuracy 0.02 %
Page 4
March 2012
CALPORT 300
3-phase Meter and Instrument Transformer Test System
40 mV … 480 V
1 mA … 120 A
Accuracy 0.05 %
6 current inputs parallel for primary /
secondary current measurement
Measurements of all electrical
parameters (incl. vector diagram)
CT / PT testing (burden, ratio)
Options:
CALSOFT Software
Clamp-on CTs for 100A
1000A FLEX 3000 up to 3000A
LiteWire Sensors up to 2000 A
and 40 kV
Page 5
March 2012
PWS 3.3
3-phase Portable Working Standard and PQ Analyzer
Working Standard Functions
20 mV … 600 V (phase-neutral)
1 mA … 12 A direct connection
Measurements of all electrical
parameters (incl. vector diagram)
CT / PT testing (burden, ratio)
Accuracy 0.1 %, 0.05 %
PQ Analysis Functions
Harmonics Interharmonics
Signal voltages Dips
Swells Interruptions
Voltage unbalance
Options:
Clamp-on CTs for 100A 1000A FLEX 3000 up to 3000A
LiteWire Sensors up to 2000 A and 40 kV
Page 6
March 2012
PWS 2.3 PLUS
3-phase Working Standard
20 mV … 300 V (phase-neutral)
1 mA … 12 A direct connection
10 mA … 100 A via clamp-on CTs
Measurements of all electrical
parameters (incl. vector diagram)
CT / PT testing (burden, ratio)
Accuracy 0.1 %, 0.2 %
Options:
CALSOFT I Software
Clamp-on CTs for 1000A
FLEX 3000 up to 3000A
LiteWire Sensors up to 2000 A
and 40 kV
Page 7
March 2012
CheckMeter 2.3
3-phase Working Standard
10 V … 300 V Auxiliary supply
from the auxiliary supply or the
measuring circuit
10 mA ... 100 A via clamp-on CTs
Measurements of:
voltage, current, active, reactive
and apparent power, energy,
frequency, power factor, error
measurement, vector diagram
Accuracy 0.2 %
Options:
CALSOFT I Software
Clamp-on CTs up to 120 A
(Measuring range 100 mA … 120 A,
Cable : max 52 mm)
Page 8
March 2012
CheckMeter 2.1
3-phase Working Standard
10 V ... 300 V Auxiliary supply
from the auxiliary supply or the
measuring circuit
10 mA ... 100 A via clamp-on CT
Measurements of:
voltage, current, active, reactive
and apparent power, energy,
frequency, power factor, error
measurement
Accuracy 0.2 %
Options:
CALSOFT I Software
Clamp-on CTs up to 120 A
(Measuring range 100 mA …120 A,
Cable : max 52 mm)
Page 9
March 2012
MTE Portables
Page 10
March 2012
PPS 400.3-12 A
3-phase portable Voltage and Current Source
0 V ... 300 V / 50 VA / Phase
1 mA ... 12 A / 30 VA / Phase
Phase shifter -180° ... 0 ... +180°
45 ... 400 Hz
Stability 0.005 %/h ( = 150 s)
Generation of harmonics up to 31st
Ripple control signals
Options:
CALSOFT II
CAMCAL for Windows
Page 11
March 2012
PPS 400.3-120 A
3-phase portable Voltage and Current Source
0 V ... 300 V / 50 VA / Phase
1 mA ... 120 A / 80 VA / Phase
Phase shifter -180° ... 0 ... +180°
45 ... 400 Hz
Stability 0.005 %/h ( = 150 s)
Generation of harmonics up to 31st
Ripple control signals
Options:
CALSOFT II
CAMCAL for Windows
Page 12
March 2012
PPS 3.3 C
3-phase portable Voltage and Current Source
0 V ... 480 V / 30 VA / Phase
1 mA ... 120 A / 60 VA / Phase
Phase shifter -180° ... 0 ... +180°
45 ... 400 Hz
Stability 0.03 %/h ( = 150 s)
Generation of harmonics up to 31st
Ripple control signals
Options:
CALSOFT II
CAMCAL for Windows
Page 13
March 2012
CheckSource 2.3
3-phase electronic Current Source
1 mA ... 6 A / 8 VA / Phase
Phase shifter -180° ... +180°
Stability better than
0.03 % (30 min)
0.1 % (1 h)
Single phase supply
50 VA (typical)
65 VA (maximum)
Options:
CALSOFT Software
Page 14
March 2012
MTE Portables
Page 15
March 2012
PTS 400.3
3-phase portable
Test system with Voltage and Current Source
Voltage source 0 ... 300 V
Current source 1 mA ... 12 A / 120 A
Reference standard accuracy
class 0.02 %
Measurement of all electrical values
Vector diagram, harmonic test,
Data storage, Ratio test,
Burden test
Automatic test runs without
external PC
Options:
High current cables up to 120 A
Several Clamp-on CT´s
CALSOFT II Software
CAMCAL for Windows
Page 16
March 2012
PTS 3.3 C
3-phase portable
Test system with Voltage and Current Source
Voltage source 30 ... 480 V
Current source 1 mA ... 120 A
Integrated working standard
accuracy class 0.05 %
Measurement of all electrical values
Vector diagram, Harmonic test,
Data storage, Burden test
Automatic test runs without
external PC
Options:
High current cables up to 120 A
Clamp-on CT´s 10 mA ... 100 A
CALSOFT II Software
Page 17
March 2012
Checksystem 2.1 S
1-phase portable
Test system with Current Source
Measurement range 10 mV ... 480 V
Current source 1 mA ... 120 A
Integrated working standard
accuracy class 0.05 %
Measurement of all electrical values
Vector diagram, Harmonic test, Data
storage
Automatic test runs without
external PC
Options:
Clamp-on CT 10 mA ... 100 A
CALSOFT Software
Page 18
March 2012
PTS 3.1 C
1-phase portable
Test system with Voltage and Current Source
Voltage source 30 ... 480 V
Current source 1 mA ... 120 A
Integrated working standard
accuracy class 0.1 %
Measurement of all electrical values
Vector diagram, Harmonic test,
Data storage, Burden test
Automatic test runs without
external PC
Options:
High current cables up to 120 A
Clamp-on CT 10 mA ... 100 A
CALSOFT II Software
Page 19
March 2012
PTS 2.3 C
3-phase portable
Test system with Current Source
Measurement range 20 mV ... 500 V
Current source 1 mA ... 120 A
Integrated working standard
accuracy class 0.1 %
Measurement of all electrical values
Vector diagram, Harmonic test,
Data storage, Burden test,
C.T. ratio test
Automatic test runs without
external PC
Options:
Clamp-on CTs for 100A 1000A
FLEX 3000 up to 3000A
CALSOFT II Software
Page 20
March 2012
Checksystem 2.3
3-phase portable
Test system with Current Source
Measurement range 10 mV ... 300 V
Current source 1 mA ... 16 A
Integrated working standard
accuracy class 0.2 %
Measurement of all electrical values
Vector diagram, Harmonic test, Data
storage
Automatic test runs without
external PC
Options:
Clamp-on CTs 10 mA ... 100 A
CALSOFT Software
Page 21
March 2012
Checksystem 2.1
1-phase portable
Test system with Current Source
Measurement range 10 mV ... 300 V
Current source 1 mA ... 120 A
Integrated working standard
accuracy class 0.2 %
Measurement of all electrical values
Vector diagram, Harmonic test, Data
storage
Automatic test runs without
external PC
Options:
Clamp-on CT 10 mA ... 100 A
CALSOFT Software
Page 22
March 2012
CALSOFT
Software tool to portable devices
Automatic single position measurement
Easy to understand presentation
of all stored measured values
Vector diagram
Presentation of measured values
Presentation of harmonics
Print and data export functions
Works together with following portables:
K2006
PRS 400.3 / CALPORT 300 / PWS 3.3
PWS 2.3 PLUS / CheckMeter 2.x
PTS 400.3 / PTS 3.3 C / PTS 3.1 C
PTS 2.3 C / CheckSystem 2.x
PPS 400.3 / PPS 3.3 C / CheckSource 2.3
Page 23
March 2012