PWS 2.3 PLUS
Portable Working Standard
Page 1
March 2009
Advantages / Benefits
Harmonics
measurement
Ratio test of
C.T.´s and P.T´s
Print
functions
U, I, P, Q, S, , cos, f, ...
measurements
Burden
measurements
Memory
functions
Vector
Meter error
diagram
measurements
Page 2
March 2009
Advantages / Benefits




Robust rubber protected housing
Supply from measurement circuits or auxiliary supply
Data memory for test results and customer data
Wide measuring range
with auto ranging
 Automatic clamp
detection
 Small dimensions
and light in weight
Page 3
March 2009
Why to use
 Reduction of annual losses caused by circuit & wiring
problems  faulty wirings are at the expense of the
supplier / utility
 Service-orientated handling of customer complaints
with presence and consultation
 Short reaction time on customer complaints
 Reduced expenses of complaints (fast and on-site)
 Putting-into-operation tests to eliminate faulty wirings
 Periodical tests after changes in wiring to ensure a
correct performance of the installation
 Sampling tests of contractors for metering
Page 4
March 2009
Where to use
 Energy utilities / suppliers
in metering and service
departments
 Contractors in metering and
transformer sector
 Metrological laboratories
and institutes
 Industry with large number
of meters and measuring
transformers
(airports, exhibitions areas, …)
 Manufacturers of meters
Page 5
March 2009
Technical data
Basic Characteristics




20 mV ... 300 V (phase-neutral)
1 mA ... 12 A direct connection
1 mA ... 100 A via clamp-on CTs
Measurements of all electrical
parameters (incl. vector diagram)
 CT / PT testing (burden, ratio)
 Accuracy  0.1 %,  0.2 %
Options:
 CALSOFT I Software
 Clamp-on CTs for 1000A 
LEMflex© up to 3000A 
LiteWire Sensors up to 2000 A
and 40 kV
Page 6
March 2009
Connections
Top view
[1]
[2]
[3]
[4]
Current outputs I1*, I2*, I3*
[5] Connection for clip-on CT’s
Current inputs I1, I2, I3
[6] Impulse output
Voltages connection U1, U2, U3 [7] Impulse input
Neutral connection for voltage N
Page 7
March 2009
Connections
Bottom view
[8] Serial Interface RS 232 C
[9] Sockets for supply from
measurement circuits
[10] Auxiliary supply connector
Page 8
March 2009
Optional current clamps
to the PWS 2.3 PLUS
 Error compensated clamp-on CT’s for
measurements in the range up to 100 A
 Clamp-on CT’s for measurements in the
range up to 1000 A
 Flexible current transformers LEMflex for
measurements up to 30 / 300 / 3000 A
 Hot sticks for measurement on high
voltage potential
- AmpLiteWire up to 2000 A
- VoltLiteWire up to 40 kV
Page 9
March 2009
Operation Concept
Display

Symbols

Control Keys

Page 10
March 2009
Software
Status Indications
Page 11
March 2009
Software
Main Menu
 Meter Test / Error Measurement
 Measurement, Harmonics,
Oscilloscope, Vector Analysis,
Circuit testing
 Transformer Test, Burden & Ratio
 Energy Measurement, Dial Test
 Installation (Setup)
Page 12
March 2009
Software
Error Measurement
Page 13
March 2009
Software
Measurement of load values UI, power values PQS
and display of vector diagram
Page 14
March 2009
Software
Harmonic Analysis and Waveform display
Page 15
March 2009
Software
Energy measurement, test of the energy
register error and maximum demand
Page 16
March 2009
Software
Burden measurement of voltage
and current transformer
Page 17
March 2009
Software
Current transformer ratio measurement
Page 18
March 2009
Software
Administrative data set (ADS)
Page 19
March 2009
Software
Examples of test results
Page 20
March 2009
Software
Example of printouts
Page 21
March 2009
Windows©-Software
CALSOFT
Selection of real
time readout
or
readout of sets
of data from
PWS 2.3 PLUS
memory
Page 22