Berkeley Nucleonics
Download
Report
Transcript Berkeley Nucleonics
Berkeley Nucleonics
Instrumentation Since 1963…
Management Team
David Brown, President
Mel Brown, Director of Finance
35 Years, MS Electrical Engineering
Jim McQuaid, Director of Radiation Detection Applications
45 Years, MS Electrical Engineering
John Yee, Director of T&M Application
15 Years, BA Management
10 Years, BS Nuclear Physics
Robert Corsetti, Director of Sales
5 Years, BS Neuroscience
Test and Measurement
Industry Leading Specifications
Widest Range of Signal Generators
High Voltage, NIM, Optical, TTL, ARB, Pulse
Measurement Instruments
Amp Stability, Interface Options, Low Jitter
Scope, Digital Multimeter, Frequency Counter
Price / Performance
Channel Cost, Feature-Rich
Nuclear Detection
Radiation Detection Pagers and Identifiers
Spectroscopic Portal Monitors
Accredited Training Programs
Reachback and Program Support
US DoD, US DHS, Health Physics Certified
Domestic and International Support Offices
Life Sciences
Video Microscope
Feature-Rich Microscope
Academic, Research, Investigative, Industrial
High Voltage Stimulators
Neuroscience Research
Flagship Products
Test and Measurement
NIM Pulsers and Power Supplies
Radiation Detection
Scanning Microscopes
Special Function and Custom Development
MODEL 725 Images, Summary
The Model 725 coordinates, integrates and synchronizes complicated
setups, simply, reliably and affordably. Featuring eight timing channels
with programmable logic, unique timing modes and 10 ns resolution, the
Model 725 outperforms a rack full of instruments, specialized boxes,
filters and cables. Inputs can be logic signals, switches, transducers,
interlocks, computer commands and gauges. The model 725 can be
programmed and controlled easily via Labview or Windows. It contains
sophisticated logic, gating and filtering. It has eight inputs, eight outputs
and eight separate timers.
The model 725’s logic is engineered for fast data throughput (11 ns) and
minimal throughput spread (~1 ns). It would be difficult to match this
performance with external cabling and hard-wired logic.
Model 725 - Multi-Trigger
Digital Delay Generator
MODEL 725 Features
•
•
•
•
•
Trigger-pulse delay: 50 ns - 1370s
Inputs: 8 external and 7 internal
Outputs: 8 internal (to timing processors)
Delay jitter from internal source: 200 ps
External trigger duration: 50 ns
MODEL 725 Applications
• Control, sync, gate, and pulse experiments
quickly and easily from a virtual panel
• Eliminate delay devices, external gates,
timers, additional filters and cables
• Experiment control and setup storage
• Signal Verification, Measurement, Warmup,
Interlock, Arm, Sync, Digital Delay, Trigger