Dennis Fire Appliances

Download Report

Transcript Dennis Fire Appliances

Dennis Fire Appliances
Operations & use
PTO
Step 1
Step 2
Step 3
Step 4
Move slide cover
towards the drivers
seat to lock out the
gearbox
Select drive on the
gear selector to
engage the pump drive
Move the leaver back
to engage the pump
bay throttle control
The warning light
should now show
To disengage the PTO reverse the order
Water pump
Shut off valve for Nearside
High Pressure hose reel.
Select ‘Foam’ or ‘Water’
(to be closed when not in use)
Shut off valve for Offside
High Pressure hose reel.
Select ‘Foam’ or ‘Water’
(to be closed when not in use)
Supply valve for
High Pressure
hose reels
Low pressure deliveries
Engine speed
control.
Main water tank to
pump Shut off valve
Pump drain taps
For winter draining to prevent
pump frost damage
Suction fill coupling
Please note filters must
be used on open water.
Hydrant fill to water tank
Low pressure water
Open main
water tank
to pump
Shut off
valve
Open Low
pressure
delivery valve
as required
Shut off valve for
Nearside
High Pressure
hose reel.
Select
‘Foam’ or ‘Water’
Open supply
valve for High
Pressure hose
reels
Open main
water tank to
pump Shut off
valve
High pressure water
Shut off valve for
Offside
High Pressure
hose reel.
Select
‘Foam’ or ‘Water’
Generator
Step 1
Step 2
Step 3
Step 4
Move slide cover
towards the drivers
seat
Move the leaver back
to engage the pump
bay throttle control
The warning light
should now show
Turn on the generator
switch
Light mast
These controls are found in the passengers side front locker
Rotate the valve to ‘Raise’
Press & hold the raise button until the light mast
is fully raised.
Rotate the valve to ‘Lower’ to stow the mast
Raise the engine speed in the
pump bay to maintain voltage
output
DO NOT move the vehicle with the mast raised