Cutler-Hammer - Eaton Corporation

Download Report

Transcript Cutler-Hammer - Eaton Corporation

IQ Analyzer
6400/6600 Series
Cutler-Hammer
Power Management Products
High End Metering Capabilities
Power Quality Monitoring
• Over 150 metered parameters for
comprehensive diagnostics
• Assess trends, harmonics and
waveforms to prevent process
disruptions and equipment damage
• Isolate and diagnose power quality
problems by analyzing historical
metered data
• Control energy usage and costs via
measurement, on-board data
storage and time-of-use registers
IQ Analyzer
Overview






Revenue metering accuracy
 ANSI C12.16 ( 1% )
 ANSI C12.20 ( 0.5% )
 IEC 687 / Canada ( 0.5% )
 Independent certification
Time Of Use Registers
Expanded event storage
UL/CUL/CE/CSA
New Display & Faceplate
4 Custom Display Screens
IQ Analyzer Key Features
• High-speed waveform capture
– Programmable event triggers
– 2 cycles @ 128 samples/cycle & 6 cycles @ 32
samples/cycle
– 11 channels of voltage & current information are
saved
– Local display of waveform (6600 series only)
• Measures current and voltage through 50th
harmonic
– Display harmonic spectrum on local display (6600
series only)
Sample Waveforms
Sample Waveforms
Sample Waveforms
IQ Analyzer Key Features
• CBEMA/ITIC event display via PowerNet
• dv/dt trigger captures subcycle voltage
disturbances (6600 series only)
• Communication flexibility:
– INCOM via IPONI
– Ethernet via EPONI & EPONIF
– Web Pages via WebPONI
– Modbus via MPONI (Coming Soon!)
IQ Analyzer Key Features
• The IQ Analyzer stores 44 different
minimum & maximum values including:
– Current
– Voltage
– Power
– Power Factor
– Frequency
– THD
IQ Analyzer Key Features
• On-board event data logging
• Auxiliary I/O capabilities
– Analog Outputs (4) 0-20mA/4-20mA 1% accuracy
• Added 4th output at the end of 2001
– Analog Input (1) 0-20mA/4-20mA 1% accuracy
– Digital Inputs (3) optically isolated +30Vdc
– Digital Outputs (4) Form C contacts 10A @ 240Vac
IQ Analyzer Key Features
• Monitors L-L, L-N, L-G and N-G voltage
– PT ratios from 1:1 to 5,000:1
• Monitors phase, neutral and ground
current
– CT ratios from 5:5 to 10,000:5
– Up to 40A continuous, 300A for 1 second
• Measures % Total Harmonic Distortion
(THD) for current and voltage
New Features
• New Trending Capabilities
– 4 Independent trends
– Up to 6 parameters per trend
– Can chose from over 94 parameters
– Total of 90K bytes of storage
• Single parameter every 15 min. for 234 days
– Independent memory allocation for each
trend
– Used with PowerNet for CBEMA/ITIC curve
plotting utility
CBEMA Curve Utility
New Features
• New Trending Capabilities
– Sampling rate can be set from 8 cycles to 5040
minutes (3 1/2 days)
– Trend 1-3 can save data on a discrete input
– Trend 4 can save data on an event
– If the time period is set for an integer divisor of
60 the period starts at the next full hour.
New Features
• Data Logging Features
– Time & Reason for last 504 Events
– Any meter event is saved
– New Status Change Indicators
•
•
•
•
•
Time of Alarms
Power Up
Resets
Setting Changes
INCOM Connection
New Features
• In addition to the data logging of the last
504 events last 10 Waveform Events are
also stored
• The real time clock can be synchronized
to the line to correct for long term errors
(w/o PowerNet)
• Programmable CT Polarity Setting
– Change CT polarity from calibration menu
– Last event under “Power Factor”
New Features
• Time Of Use (TOU) Energy Registers
– 32 Schedules
• 8 Weekday
• 8 Saturday
• 8 Sunday
- 8 Holiday
- 8 Seasons
– Each schedule can change 9 times a day
– 4 Different utility rates
– Watt-hours, VAR-hours, VA-hours recorded
New Features
• TOU Demands
– Amps, Watts, VARS & VA
Improvements
• New Case
– Polycarbonate for higher durability &
temperature
– Rugged outer edge
– Reset button changed from red to blue
• New Display
– Reverse mode,
LED backlit LCD
– Yellow on black
– High reliability
Improvements
• Custom Screen Enhancements
– Allows programming of 7 parameters
per screen
– Now 4 custom screens
– List of programmable items extended
• Clock
• Min/Max Values since last trend
• Magnitude THD (V and A)
– Displays each screen for 5 seconds
New IQ Analyzer
• Old IQA6000/6200 catalog numbers
replaced with new 6400/6600 series
– IQA6410
– IQA6420
– IQA6430
– IQA6610
– IQA6620
– IQA6630
-
Separate Source PS
DC PS
Self Powered Three Phase PS
Separate Source PS w/waveform
DC PS w/waveform
Three Phase PS w/waveform
Documentation
• Color Brochure
– B.17C.01.S.E
• Technical Data Sheet
– TD.17.02A.T.E
• Sales Notes
– SN.17C.03A.S.E
• Instruction Book
– TD17530D
IQ Analyzer 6600
Portable
New Portable IQ Analyzer
• New portable will be based upon the IQ
Analyzer 6600
• Waveform capture
• On board data trending
– New CT connectors
– Both INCOM & RS-232 communications
– New battery power supply
– New heavy duty case with lead storage
– Can be used with PowerPort
– Optional clamp on CT’s
Portable IQ Analyzer
Portable IQ Analyzer
• Three new optional
multi-ratio clamp-on
CT’s:
– 150/300/600 Amp
– 500/1000/1500 Amp
– 1000/2000/3000 Amp