ABL800 Analyser introduction

Download Report

Transcript ABL800 Analyser introduction

ABL800 FLEX
Introduction
RTC, December 2004
Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, www.radiometer.com
1
Agenda
• Front view
• Rear view
• Modular design
• Parameters
• Analyzer
•
•
•
•
configurations
Specifications
Sampler types
AutoCheck
Screen design
2
Front view
1. Aspiration inlet
2. Barcode reader
3. Color touch screen
3
4. Printer
5. Solutions (cleaning
4
7
1
8
6
5
2
5
calibration, rinse
and waste
containers)
6. AutoCheck
7. CD-RW drive
8. Window to
electrode modules
3
Rear view
1. Screen, rear
2. Gas containers
3. Communication ports
1
4. Power switch
5. Fan
2
5
2
3
4
4
Communication ports
• The two USB communication
1
2
3
1 USB
2 Mouse/keyboard
3 Network connections
ports provide connection to
external devices, e.g.
network, keyboard, USB
storage device
• The two other
communication ports
provide connection to
mouse and keyboard
• Furthermore there is a
printer port, a network
connector, a serial port and
a port for an external CRT
VG monitor
5
Modular design
• Allows flexibility in
parameter
availability
1
2
3
1
2
3
4
4
Inlet
pH/BG
Met/Lyt
Oximetry
6
Parameters
• There are 10 electrode slots in the two electrode modules
• One electrode slot for the reference electrode
• Nine other electrodes available for the following
parameters:
pH, pCO2,
pO2,
cK+, cNa+, cCa2+, cCl– , cGlucose, cLactate
7
Oximetry parameters
ctHb
= concentration of total hemoglobin
sO2
= oxygen saturation %
FO2Hb = fraction of oxyhemoglobin
FCOHb = fraction of carboxyhemoglobin
FHHb
= fraction of deoxyhemoglobin
FMetHb = fraction of methemoglobin
FHbF
= fraction of fetal hemoglobin
ctBil
= concentration of bilirubin
8
Analyzer configuration
BG
OXI
ctHb/sO2 ctBIL/FHbF
835



830















825
820
815
810
805
800

LYT
MET









Models ABL835, ABL830 and ABL800 of the ABL800 FLEX analyzers
are not available at the time of the release
9
Specifications – analysis details
• Sample volumes
- Macromodes 195 L (all parameters)
- Micromodes 35-95 L (all parameters)
• Measuring time
- Macromodes 80 sec., cycle time 150 sec., approx. 24 samples/hr
- Micromodes 80-135 sec., cycle time 145-200 sec., approx. 18 samples/hr
• Derived parameters
- 47 different derived parameters to choose from. See the types and definition in
teh ABL800 FLEX Specification sheet
10
Specifications - communications
• Computer specification
- Intel Celeron Processor
- Windows XP embedded
• True multi-tasking system
- Intel Celeron processor for DMS software
- Dedicated 80386 CPU for wet section
• Communication
- LIS/HIS communication based on ASTM and HL7
- Network communication – Ethernet (TCP/IP protocol as communication
protocol)
- True two-way communication
11
Customizable
• Very comprehensive setup programs
- More functions than ever can be customized
- Examples: operators and passwords, corrective actions, reference and critical
ranges etc.
• Automatic restart after replacements
• On-line help systems
- Video tutorials
- Help
- troubleshooting
• Connection to RADIANCE
- Especially analyzer remote control module
12
Sampler types
Syringe
Expired air
Capillary tube
QC with adapter
Test tube
13
AutoCheck
• Automated QC measurements
• Eliminates user-to-user
variance - results only reflect
analyzer performance
• Time-saving
• Holds 20 ampoules
14
Color touch screen
•
1
•
Operation and management
of the analyzer are performed
via the color touch screen
The screen is divided into
three sections
1. Top section/status bar varies
2
3
1 Top section
2 Center section
3 Bottom section
slightly according to the
status of the analyzer and
setup
2. Center section contains the
main information and
interaction area
3. Bottom section contains
navigation buttons and varies
slightly according to the
screen in question
15
Top section
3
The status bar describes the
current task
•
1
2
-
1 Status bar
2 Parameter bar
3 Traffic light
E.g. calibration, rinse, aspiration
The time bar is present when the
analyzer is performing a task
•
The parameter bar lists all
the measured parameters
available and activated
•
The traffic light gives an
overview of various analyzer
activities and the traffic light
color shows the overall status
of the analyzer – see the “02
What is what” presentation
for a further description
16
Center section
•
The center section is the
main information and
interaction area
•
Each screen is identified by
an icon and a name that
matches the button that
gives access to it
•
The screen may contain text,
check buttons, scroll bars, a
screen keypad or screen
keyboard
17
Bottom section
The bottom section changes
with the different options,
depending on the screen in
question
1. In the Ready screen
•
-
-
1
Access various information, e.g.
the current time, next QC, if
connected to RADIANCE
The buttons can be selected to give
access to e.g. Logon/Log Off, the
Menu
2. General navigation buttons
Quality Control Result screen:
3
2
-
“Close” – close actual window
“Back” – go one step backwards
3. Other navigation buttons
1 Main menu
2 General navigation buttons
3 Other navigation buttons
-
Results, ID, messages, print, etc.
18
Radiometer Training Center, December 2004
Radiometer Medical ApS, Åkandevej 21, DK-2700 Brønshøj, Tel: +45 38 27 38 27, www.radiometer.com
19