EATON ePDU G3 (Generation 3)
Third-generation ePDU technology for best-in-class power distribution
May 2014
Stefan Coote
© 2014 Eaton Corporation. All rights reserved.
Market Drivers
Differentiation Points
Grip – IEC Plug Retention
Reliability concerns over IEC plug retention
Prevents accidental disconnect from
being bumped or from vibration
Cost Saving – no need to buy special
cables or brackets
The need for higher accuracy in department billing
and colocation data centers
True IEC +/-1% Billing Grade
Accuracy
Monitor equipment extremely accurately
Modern hot-air containment solutions and the
newest server technologies result in higher rack
operating temperatures
60˚ Operating Temperature
Serviceability problems related to rack PDU
• Access to hot-swap components in IT equipment
• How to avoid downtime if a rack PDU becomes
faulty?
No Downtime on Upgrades
ePDU G3 can be used in very hot
environments
Low profile form factor to access IT equipment
and Hot Swap fans etc
ePDU G3 has Hot-Swap network components
75% Reduction in network Cost
Cost of networking for monitoring a rack PDU
Daisy chain 4 ePDUs from one IP port
reducing network
costs by 75%
2
2
Value Proposition
• Reliably distribute, accurately monitor and
control the power consumption of your IT
equipment
• See where you have available power and are most
efficient
• Management software allows mass control, mass
configuration and analysis, plus Hypervisor and
UPS integration
• Integral part of Eaton’s Intelligent Power Pod
• Made in EMEA - fast shipping times
• Custom units available to meet your needs
3
3
Growing Functionality
Eaton ePDU G3 Levels of Technology
Managed
Switched Outlet + Metered Outlet
Switched
Switched Outlet + Metered Input
Metered Outlet
Metered Outlet
Metered Input
Metered Input and Branch Circuit
In-Line Metered
Add Metering to upgrade Basic PDUs
Basic
Basic Reliable Power Distribution
Q4/
2015
Q2
G3 Platform is designed for Both Standard off-the-shelf models and Custom models
4
4
Prevent accidental disconnect
IEC Outlet eGrip Plug Retention
• Secures plugs in place
with a lever activated
grip integrated into each
outlet
• Prevents accidental
disconnect from being
bumped or from rack
vibration
• Eliminates bulky cable
management bars that
block airflow and
decrease serviceability
Works with standard cables - No need for the customer to buy special cables
5
5
True IEC Class 1 Billing Grade Accuracy
Increasing demand
for power
Increasing cost
of power
• There is a demand for higher
accuracy in department billing
and colocation data centers
• To bill customers for energy used
• Closely monitor consumption
• Define racks and areas with available power
Eaton ePDU G3 offers
• IEC Class 1 - Billing Grade Accuracy
• Available across whole technology range
6
6
Central Management of your ePDU
• Advanced LCD display with menu
system
• Rotate display for top and bottom fed
ePDU
• Read current, voltage, power, kWhr
and more
• Change settings
• Optional Environmental
monitoring probe
• Configuration and Upgrade
• Via USB stick configuration file
• En Masse via IPM software
• Daisy Chain capability
7
7
Reduce IP Ports  Daisy Chain 4 ePDUs
• Chain four ePDUs from one IP address and network port
• Manages power supplies on different feeds through one
interface
• Reduces physical infrastructure installation costs by 75%
• Saves on CapEx and simplifies management
Network switch
2
1
3
4
4
2
8
8
No Down Time On Updates
Hot-Swap eNMC
• eNMC module contains meter, network ports, LCD display and CPU
• Hot Swappable - No loss of power to IT equipment when replacing
• Firmware updates - with no loss of power to IT equipment
• Field serviceable with no down time
9
9
Doesn’t protrude into the rack –
even at the breakers
• Width and height are optimized
for multiple mounting options
• Design prevents interference
with the rail - won’t block hot
swap fans and power supplies
• Low-profile circuit breakers
10
10
Critical element – Low Profile Form Factor
• Standard chassis size
• 52mm wide, 53mm deep, 58.7mm at breakers
• All IEC units, all technologies
• Even for 32A 3 Phase Units
• Deep base chassis
• Switched and Managed ePDU G3 with National outlets
and some custom units
• 52mm wide, 65mm high, 70.7mm at breakers
11
11
Easy Installation –
Multiple Options as Standard
•
Mounting buttons are pre-installed to save installation
time
•
Button locations on the side to mount G3 at a 90degree rotation in the rack
•
Double-sided buttons accommodate variations of rack
metal thickness
•
Patented variable mounting
brackets allow true mounting
flexibility 12
12
Easy Installation + Extremely flexible
• Raise or lower the
ePDU in the rack
• Change the distance
between mounts
G3 Platform is designed to have the most flexible installation13 on the market
13
60˚ Operating Temperature
Can be used in very hot environments
• Basic and Metered Input G3
• 60ºC CE rated
• IT equipment manufacturers
are increasing operating
temperatures
• Allows Data Centres to reduce
cooling costs by increasing
operating temperatures
• Hot-air containment solutions
provide higher in-rack PDU
temperatures
Optional environmental
monitoring probe with
2 dry contacts
(all except Basic ePDUs)
14
14
Simplify Load Balancing
Easily link breakers to outlet groups
•
•
•
•
•
•
Yellow, blue, red, orange, purple and green
coding
Colour-coded outlet sections match a
corresponding circuit breaker
Simplifies load balancing
Easily identify which circuit breaker feeds
which outlets
Laser engraved chassis clearly indicates
outlet groups and outlet numbers
Groups are either branch circuits or phases
and are marked on both sides
Easily link breakers to outlet groups
15
15
G3 Key Features – Across The Whole Range
G3 Key technology
features
IEC outlet eGrip plug
retention
±1% IEC Class 1 Billing
Grade Accuracy
Colour-coded outlet and
breaker sections
Hot-Swap eNMC + Optional
Temp/Humidity sensor
Low-profile form factor
High operating
Temperatures
Daisy Chain Network
Multiple Install Options
Energy Wise Ready
Basic
In-Line
Metered
Metered
Input
Metered
Outlet
√
N/A
√
√
√
√
N/A
√
√
√
√
√
√
√
√
√
√
√
N/A
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
N/A
√
√
√
√
√
√
√
√
√
√
√
N/A
√
√
√
√
√
Switched Managed
16
16
Supervision and Control
in a single interface
• Intelligent Power Manager is a critical part
of Eaton’s Intelligent Power Pod for the
data centre:
• Integrates with VMware, Citrix
• Trigger automatic migration of virtual servers
in the event of a power failure
• Site recovery and full integration in the
VMware interface
• ePDU and UPS supervision and control
•
•
•
•
ePDU and UPS Energy Management
En masse Configuration of ePDU
En masse Update of ePDU
One interface to monitor + control your power
usage
17
17
Need Something Special?
Dedicated Engineering teams to create your perfect ePDU
• Dedicated Engineering Teams in centres of
excellence to work on specific configurations
and significant projects
Simple Configuration Changes
Complex Engineering Project
Criteria
Criteria
-
€10k order or Significant
customer for other equipment
-
Major project or customer
-
Specific functionality required
Simple change to standard units
18
18
Need Something Special?
Dedicated Engineering teams to create your perfect ePDU
Simple Configuration Changes
Complex Engineering Project
Quotation - 24 hour turnaround
Quotation – dependant on complexity
Delivery – 4 weeks from order
Delivery – dependant on complexity /
approvals / parts needed
Outlet changes - Number and type
C13, C19, UK, GE, FR
Mix up to 3 types of outlets on 1
ePDU
Length of 0U chassis
Length of input cord, and input plug
type
19
19