frame-relay interface

Download Report

Transcript frame-relay interface

WAN Technologies
FRAME RELAY
Frame Relay: An Efficient and Flexible WAN Technology
 Frame Relay has become the most
widely used WAN technology in the
world.
Large enterprises, ISPs, and small
businesses use Frame Relay, because
of its price and flexibility.
Example: Chicago to New York
requires a speed of 256 kb/s.
◦Three other sites need a maximum
speed of 48 kb/s connecting to the
Chicago headquarters,
◦The connection between the New
York and Dallas branch offices
requires only 12 kb/s
◦What options are possible?
Solution 1: Using Leased Lines
The Chicago and New York sites
each use a dedicated T1 line
(equivalent to 24 DS0 channels)
to connect to the switch, while
other sites use ISDN
connections (56 kb/s).
◦Because the Dallas site
connects with both New York
and Chicago, it has two locally
leased lines.
◦These lines are truly dedicated
in that the network provider
reserves that line for Span's own
use.
Problems with leased line solution
◦Lack of efficiency:
 Of the 24 DSO channels available
in the T1 connection, the Chicago
site only uses seven.
Some carriers offer fractional
T1 connections in increments
of 64 kb/s, but this requires a
specialized multiplexer at the
customer end to channelize the
signals.
 In this case, Span has opted for
the full T1 service.
 The New York site only uses five
of its 24 DSOs.
 Dallas needs to connect to
Chicago and New York, there are
two lines through the CO to
each site
Solution 2: Frame Relay
Frame Relay is a more costeffective option.
 With Frame Relay, customers
only pay for the local loop, and
for the bandwidth they
purchase from the network
provider.
Distance between nodes is
not important.
with dedicated lines,
customers pay for an end-toend connection. That includes
the local loop and the
network link.
 Frame Relay's shares bandwidth
across a larger base of
customers. Typically, a network
provider can service 40 or
more 56 kb/s customers over
one T1 circuit.
Frame Relay based WAN
When use Frame Relay to interconnect LANs
1. A router on each LAN is the
DTE.
2. A serial connection, such as a
T1/E1 leased line, connects the
router to the Frame Relay
switch of the carrier at the
nearest POP(point of presence)
for the carrier.
3. The Frame Relay switch is a
DCE device.
4. Network switches move frames
from one DTE across the
network and deliver frames to
other DTEs by way of DCEs.
Virtual Circuits






The connection through a Frame
Relay network between two DTEs
is called a virtual circuit (VC).
The circuits are virtual because
there is no direct electrical
connection from end to end.
With VCs, any single site can
communicate with any other single
site without using multiple
dedicated physical lines.
VCs are identified by DLCIs (data
link connection identifier).
DLCI values typically are assigned
by the Frame Relay service
provider.
Frame Relay DLCIs have local
significance, which means that the
values themselves are not unique
in the Frame Relay WAN.
Mapping Virtual Circuits








In the figure, there is a VC between the
sending and receiving nodes.
The VC follows the path A, B, C, and D.
Frame Relay creates a VC by storing
input-port to output-port mapping in
the memory of each switch
As the frame moves across the
network, Frame Relay labels each VC
with a DLCI.
The DLCI is stored in the address field
of every frame transmitted to tell the
network how the frame should be
routed.
The frame uses DLCI 102. It leaves the
router (R1) using Port 0 and VC 102.
At switch A, the frame exits Port 1
using VC 432.
This process of VC-port mapping
continues through the WAN until the
frame reaches its destination at DLCI
201.
Frame Relay Topologies
Star Topology (Hub and Spoke)

The simplest WAN topology is a star.

In this topology, Span Engineering has a central
site in Chicago that acts as a hub and hosts the
primary services.
◦ The Span has grown and recently
opened an office in San Jose. Using
Frame Relay made this expansion
relatively easy.

When implementing a star topology with
Frame Relay, each remote site has an access
link to the Frame Relay cloud with a single VC.
◦ The hub at Chicago has an access link
with multiple VCs, one for each
remote site.

The lines going out from the cloud represent
the connections from the Frame Relay service
provider and terminate at the customer
premises.

Because Frame Relay costs are not distance
related, the hub does not need to be in the
geographical center of the network.
Frame Relay Address Mapping – Dynamic Mapping

Before a router is able to transmit data over Frame Relay, it needs to know
which local DLCI maps to the Layer 3 address of the remote destination.

This address-to-DLCI mapping can be static or dynamic mapping.
Dynamic Mapping (Inverse ARP)

Dynamic Inverse ARP relies on the presence of a direct point-to-point connection
between two ends and Inverse ARP to resolve a next hop network protocol
address to a local DLCI value.

The Inverse Address Resolution Protocol (ARP) obtains Layer 3 addresses of other
stations from Layer 2 addresses, such as the DLCI in Frame Relay networks.
Frame Relay Address Mapping-Static Mapping
Static Mapping (Inverse ARP)
 static mapping maps the next hop protocol address to a local DLCI
 hub-and-spoke topology uses static address mapping on the spoke
routers to provide spoke-to-spoke reachability
Frame Relay address mapping

Static Mapping
Configuring FR
Configuring FR (contd.)
Configure a static Frame Relay map
Frame Relay NBMA topology
Frame Relay Subinterfaces
Solving Reachability Issues: Subinterfaces

Frame Relay can partition a physical
interface into multiple virtual
interfaces called subinterfaces.

To enable the forwarding of broadcast
routing updates in a Frame Relay network,
you can configure the router with logically
assigned subinterfaces

Point-to-point - A single point-to-point
subinterface establishes one PVC
connection to another physical interface
or subinterface on a remote router.

Each pair of the point-to-point routers is on its
own subnet, and each point-to-point
subinterface has a single DLCI.

Multipoint - A single multipoint
subinterface establishes multiple PVC
connections to multiple physical interfaces
or subinterfaces on remote routers.
Configuring Frame Relay Subinterfaces



Frame Relay subinterfaces ensures that a physical interface is
treated as multiple virtual interfaces.
To create a subinterface, Specify the port number, followed by a
period (.) and the subinterface number.
◦R1(config-if)#interface serial 0/0/0.103 point-to-point
◦To make troubleshooting easier, use the DLCI as the
subinterface number.
◦You must also specify whether the interface is point-to-point or
point-to-multipoint using either the multipoint or point-to-point
keyword.
The DLCI is also required for multipoint subinterfaces for which
Inverse ARP is enabled.
◦R1(config-subif)#frame-relay interface-dlci 103.
◦DLCI number is not required for multipoint subinterfaces
configured with static frame relay maps.
◦The DLCI range from 16 to 991.
Configuring Frame Relay Subinterfaces

In the figure, R1 has two point-to-point
subinterfaces, each on a different subnet.
◦s0/0.0.102 connects to R2,
◦s0/0/0.103 connects to R3.
◦ Step 1. Remove any network layer
address assigned to the physical interface.
◦ Step 2. Configure Frame Relay encapsulation
on the physical interface
encapsulation frame-relay.
◦ Step 3. For each of the PVCs, create a
subinterface.
◦ Step 4. Configure an IP address for the
interface and set the bandwidth.
◦ Step 5. Configure the local DLCI on the
subinterface using the
 frame-relay interface-dlci <>
Example: Point-to-point sub-interfaces
Use the frame-relay interface-dlci for local DLCI on the subinterface
Bandwidth control
Troubleshooting Frame Relay

The following commands can be used to
help verify frame relay configuration
–Show interfaces
–Show frame-relay lmi
–Show frame-relay pvc ###
–Show frame-relay map

Use the following command to help
troubleshoot a frame relay configuration
–Debug frame-relay lmi
Verifying FR configuration.
Summary




Frame relay is the most widely used WAN technology
because it:
–Provides greater bandwidth than leased line
–Reduces cost because it uses less equipment
–Easy to implement
Frame relay is associated with layer 2 of the OSI model and
encapsulates data packets in a frame relay frame
Frame relay is configured on virtual circuits
–These virtual circuits may be identified by a DLCI
Frame relay uses inverse ARP to map DLCI to IP addresses
Summary
 Configuring
frame relay requires
–Enable frame relay encapsulation
–Configuring either static or dynamic
mapping
–Considering split horizon problems
that develop when multiple VCs are
placed on a single physical interface