WinCC-features

Download Report

Transcript WinCC-features

SIMATIC WinCC V5.0
WinCC V5 Under Windows NT
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 1
WinCC_V5_xie8.ppt/Sch
SIMATIC WinCC V5.0
Highlights of the Version
 MultiServer
 Web Navigator
 Totally Integrated Automation
 Efficient Configuration
 Functional Enhancements in the Graphics Designer
 Enhancements to Communications
 Enhancements in WinCC V5 Service Pack 1
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 2
WinCC_V5_xie8.ppt/Sch
Multi Server
Overview
Distribution of Servers
 Higher Performance Profile
 Easier Expansion of the System
 Better Performance
WinCC - scaleable from a
single-user station up to a
distributed system.
 Multi Client as a Common View of the Servers
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 3
WinCC_V5_xie8.ppt/Sch
Distribution of Servers
Overview
Performance Profile
 6 servers (redundant pairs too) with up to 16 clients (tested performance profile)
Distribution is Solved by Configuration
 Functional distribution, e.g. for archiving and visualization
 Distribution to subsystems
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 4
WinCC_V5_xie8.ppt/Sch
Distribution of Servers
Functional Distribution
Multi Client
Trend Server
Alarm Server
Visualization
Server
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 5
WinCC_V5_xie8.ppt/Sch
Distribution of Servers
Distribution to Subsystems
Multi Client
Plant Section 1
Plant Section 2
Plant Section 3
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 6
WinCC_V5_xie8.ppt/Sch
Distribution of Servers
Configuration of Distributed Systems
1.
Transfer/Conversion of Version 4 Projects and Pictures
2.
Independent Configuration of the Servers
(in accordance with Version 4.x)
3.
Generation of Server Data
The server package contains a list of picture names, variables and
archives of the server that a Multi Client needs for its configuration.
4. Configuration of the Multi Client Project
WinCC Server
WinCC Multi Client
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 7
WinCC_V5_xie8.ppt/Sch
Multi Client
Overview
The Multi Client takes an important part
in a distributed system
A Multi Client provides a common view of




the process data of distributed servers in one picture
all the measured value archives, e.g. in one curve window
all the message archives
the pictures/picture windows of different servers
Integration and bringing
together of different
server projects at the
Multi Client
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 8
WinCC_V5_xie8.ppt/Sch
Multi Client
Configuration of the Multi Client
The Multi Client has its own project
The server data is loaded on the Multi Client
The view of the different servers is based on a
new property: the server prefix ServerName::TagName
The system automatically transfers the server prefix to
scripts, controls, pictures on the Multi Client
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 9
WinCC_V5_xie8.ppt/Sch
Multi Client
Overview of Distributed System
The Multi Client has its own
project including additional
pictures, e.g. for a common
WinCC Multi Client plant-wide alarm
Standard
view. Client
WinCC
Server1
WinCC
Server2
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 10
WinCC_V5_xie8.ppt/Sch
Multi Client
View of Tags of Different Servers
WinCC Multi Client
I/O field linked to
“Server1::Tag1”
WinCC
Server1
SIMATIC HMI - Human Machine Interface
WinCC Version 5
I/O field linked to
“Server2::Tag2”
WinCC
Server2
A&D PT1 M/05.04.00/N° 11
WinCC_V5_xie8.ppt/Sch
Multi Client - View of Process
Value Archives of Different Servers
Server1::Tag1
Server2::Tag2
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 12
WinCC_V5_xie8.ppt/Sch
Multi Client - View of
Message Archives of Different Servers
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 13
WinCC_V5_xie8.ppt/Sch
Multi Client - View of
Picture Windows of Different Servers
Server1::
Server2::
WinCC Multi Client
WinCC
Server1
WinCC
Server2
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 14
WinCC_V5_xie8.ppt/Sch
Multi Client
View of Pictures of Different Servers
Server1
Server2
Multi Client Overview Picture
WinCC Multi Client
Serv 1 Overview Picture
Server Picture
Serv 2 Overview Picture
Server1
Server2
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 15
WinCC_V5_xie8.ppt/Sch
Web Navigator
Overview
Web Navigator Server
 Communication to the WinCC Server
 Administration of Access Rights
Web Navigator Client
WinCC Goes Web
Operation and monitoring
of the plant via the
Worldwide Web
 Operation and Monitoring Over the Web
 Limited operator inputs or purely view only function depending on the
access rights
 Minimum installation including WinCC ActiveX controls via network too
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 16
WinCC_V5_xie8.ppt/Sch
Web Navigator
Plant Configuration I
Web Client
Firewall
Web Server
WinCC Data Source
Web Server
Client-PC
HTTP Request
HTTP Result
Browser
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 17
WinCC_V5_xie8.ppt/Sch
Web Navigator
Plant Configuration II
Web Client
Firewall
Web Server
WinCC
WinCC Data Source
Web Server
Client PC
HTTP Request
HTTP Result
e.g.
OPC
Browser
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 18
WinCC_V5_xie8.ppt/Sch
Web Navigator
Plant Configuration III
Web Client
Firewall
Web Server
WinCC
Maximum safety by
WinCC
DataSource
physical
separation
of
plant network and Internet
Web Server
Client PC
Http Request
Http Result
Browser
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 19
WinCC_V5_xie8.ppt/Sch
Web Navigator Client
Strengths
 Plant visualization and operation across the Interne /
Intranet
 Web Navigator Client is a thin client (up to 50 clients)
 View of the plant or manufacturing information for Managers
 Direct plant control by remote diagnostics for example
 Safety by several levels of security
 User-specific password
 Firewall technology
 Support of encoded communication
 Minimal installation at client side (no entire WinCC system)
 Direct use of WinCC pictures for the web
 Optimized communications and performance
 Optimization of WinCC pictures
 Pictures can be transferred directly
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 20
WinCC_V5_xie8.ppt/Sch
Web Navigator Client
Limitations of the Web Client
When transferring the comprehensive WinCC Runtime
functionality to the minimum web client execution
environment, there are some limitations:




No logs (log output on the web client is not supported)
No online configuration of server projects
No user archives
No global scripts
Project and global functions must be present on the local system:
this is of course not possible with a Web client. As a result, these
functions are not executed on the Web client.
The system does support event-triggered scripts (e.g. on mouse
click) in pictures and on objects.
 Referenced graphics (e.g. bitmaps) on buttons, graphic objects etc.
are not displayed
 No full PCS7 support, e.g. navigation through pictures
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 21
WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation
Overview
Direct Use of STEP 7 Symbols in WinCC
STEP 7 Block Call from WinCC Runtime
Entry into STEP 7 Hardware Diagnostics
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 22
WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation
Interconnection of STEP7 Symbols
WinCC Project as a Part of the STEP 7 Project
Interconnection of STEP 7 Symbols from the WinCC
Tag Dialog
•No duplicate input of
tags.
•Direct access to STEP 7
data.
WinCC tag dialog box of the
Graphics Designer with
view of the STEP 7 data
store.
•Addressing errors
avoided due to
consistency
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 23
WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation
STEP 7 Block Call
STEP 7 Block Call from WinCC Runtime
 Representation of active networks
 Return to the corresponding WinCC picture
 Navigation to different places of use
Rapid, guided diagnostics
in the STEP 7 program.
SIMATIC HMI - Human Machine Interface
WinCC Version 5
Jump to a defined STEP 7
network from a WinCC
picture in runtime for
diagnostic purposes.
A&D PT1 M/05.04.00/N° 24
WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation
STEP7 Block Call Overview
Symbol Table
(Automatic)
Network Entry
Symbol Places of Use
FB1 Network x
FB2 Network y
Return to the WinCC Picture
S7 Network
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 25
WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation
Entry into STEP 7 Hardware Diagnostics
Start of the STEP 7 function „hardware diagnosis“
from WinCC Runtime
Hardware error detection in WinCC e.g. via a message
HW error
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 26
WinCC_V5_xie8.ppt/Sch
Efficient Configuration
Overview
Cross-Reference List




Listing in table form of tags, pictures, functions ...
Selective lists
Central rewiring
Jump from the cross-reference list to the tags' place of use
Display of all the dynamic properties of a picture
Dragging and dropping of tags
Rapid rewiring of tags in pictures
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 27
WinCC_V5_xie8.ppt/Sch
Efficient Configuration
Cross-Reference List
Listing in table form of tags, pictures, functions ...
Direct rewiring or jump
to place of use
Subdivided by variables in use or not in use
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 28
WinCC_V5_xie8.ppt/Sch
Efficient Configuration
Cross-Reference List
Selective lists in accordance with the filter setting
 Selection
by objects, e.g. pictures
as in use or not in use
 Search in pictures, functions,
archives, messages
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 29
WinCC_V5_xie8.ppt/Sch
Efficient Configuration
Picture Properties
Picture preview
Display of picture dynamization in an overview or
selectively by type of dynamization
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 30
WinCC_V5_xie8.ppt/Sch
Efficient Configuration
Dragging & Dropping Tags
Tag linking in the
Graphics Designer
by means of drag & drop
Rapid rewiring
of variables in pictures
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 31
WinCC_V5_xie8.ppt/Sch
Functional Enhancements (Graphics Designer)
User Interface
Tag and ActiveX Toolbar
Multiline Button Labels
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 32
WinCC_V5_xie8.ppt/Sch
Functional Enhancements (Graphics Designer)
Trend/Alarm Windows as ActiveX Controls
Conversion of Application Window to ActiveX Controls
 Direct display and configuration of message and trend windows after pasting
the controls in the Graphics Designer
 Storage of sample controls in the library
New Functions of the Controls
 Online trend window without its own archive
 Free definition of number of places after decimal point in Table Control
Direct display of trend
and alarm windows in
Graphics Designer
Quick configuration dialog
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 33
WinCC_V5_xie8.ppt/Sch
Functional Enhancements (Graphics Designer)
Display of DXF Data
Display of DXF Data (E-Plan, AutoCAD)




Output via an ActiveX control
Zoom function in the view
Wizard support
Central or local data storage possible of DXF files
View of the plant data for
trouble-shooting, for example,
right down to the wiring diagram from WinCC Runtime.
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 34
WinCC_V5_xie8.ppt/Sch
Enhancements to Communication
General Expansion of Channels
Channel-specific help files
Channel-specific log files
Diagnosis of communications problems
like addressing errors in
the LOG file, for
example.
Ehanced channel diagnosis for the following channels:
 SIMATIC S5 Ethernet Layer 4 / TF
 SIMATIC S5 AS511 / Serial 3964R
 SIMATIC S7 Protocol Suite
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 35
WinCC_V5_xie8.ppt/Sch
Enhancements to Communication
Expansion of Channel Diagnosis
Connection Monitoring
Trace Control
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 36
WinCC_V5_xie8.ppt/Sch
Enhancements to Communication
Expansion of the SIMATIC S7 Channel
Increase in the number of units for
 Profibus (CP5412A2)
 Industrial Ethernet (CP1413)
 For this type of communications, you can fit two CPs
Connection of twice as
many controllers.
Write jobs can be processed with priority
Support for the S7-400's H-CPU
 Profibus
 Industrial Ethernet
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 37
WinCC_V5_xie8.ppt/Sch
Enhancements to Communication
WinCC Redundancy
WinCC Clients
WinCC Redundancy:
a Global Concept
Redundant WinCC Server
Redundant
Profibus or
Industrial Ethernet
S7-400-H
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 38
WinCC_V5_xie8.ppt/Sch
Enhancements to Communication
Communications Manual
Overview of Communications
Help in Making Decisions
Numerous very comprehensive examples ranging from
AS through drivers to WinCC
Sample projects for STEP 5 / 7 and WinCC
Notes on diagnostics
•A communications manual for
beginners and experts.
•Establishing communications
explained step-by-step.
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 39
WinCC_V5_xie8.ppt/Sch
Enhancements to Communication
OPC
Enhancement of OPC capability by adding functions of
the current V2.0 specification
 Support for Automation and Customer Interface
 Direct access to the Automation Interface via VBA (e.g. Excel)
OPC Client
OPC Automation Interfaces
OPC Custom Interfaces
OPC Server
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 40
WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1
 The WinCC V5.0 SP1 Update can be performed by an
additional installation procedure. A previous deinstallation of WinCC V5.0 ist not necessary.
WinCC V5.0
Service Pack 1
SIMATIC HMI - Human Machine Interface
WinCC Version 5
WinCC V5.0 SP1
A&D PT1 M/05.04.00/N° 41
WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1
System Channel
• A system channel can be added
as a channel DLL
• System time, date, weekday
tag are available within WinCC
and can be passed to other
systems
• The current CPU and memory
usage can be processed
within WinCC.
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 42
WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1
New TCP/IP Channel Unit for S5
• The S5 transport channel
contains a new channel unit
for TCP/IP operation.
• This channel unit is an altertive to the ISO transport
channel unit.
• Any ethernet board can
be used..
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 43
WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1
Quality Codes for OPC Channel
• The OPC channel includes
quality codes.
• These quality codes
indicate information about
status of the variable values.
(„good“, „bad“,
„unknown“)
Direct rewiring or jump
to the location of
usage.
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 44
WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1
Cross-Reference Information from V4 Projects
• Scripts within a version 4 project
can be automatically extended
cross-reference information.
• New project functions can be
checked in the cross reference
list as well.
• The smart tool „ScriptUpgrade“
is to be found on the CD-ROM.
SIMATIC HMI - Human Machine Interface
WinCC Version 5
A&D PT1 M/05.04.00/N° 45
WinCC_V5_xie8.ppt/Sch