SITE PLANNING & BUILDING RULES - ce
Download
Report
Transcript SITE PLANNING & BUILDING RULES - ce
SITE 1
SITE 2
Site 3
Site 4
SITE 5
Selection of Site
-fairly level with good quality of soil.
- connected by roads
-good communication facilities.
-availability of electricity, water and sewer lines
-away from hazardous industries.
-avoid flood prone area, water logged area.
-amenities like schools, hospitals, shopping centres
should be nearer.
Good drainage property.
-regular shape.
-places prone to air and water pollution should be
avoided.
-proper ownership and other legal matters have to be
checked before buying a site.
SITE PLAN
The detailed plan of a plot with the necessary
surrounding data is called a site plan
Boundries of plot
Position of the site.
Details of the street with name, width etc.
All existing structures in the plot.
Existing streets and footpaths with in the plot.
Topographic contours.
North direction and wind direction.
The access to each plot sub divisions.
Layout of the proposed building.
KERALA BUILDING RULES
General requirements regarding plot.
Exterior and interior open air spaces.
Built up areas of buildings, coverage, floor area.
Size, height and ventilation of rooms.
Water supply & sanitary provisions.
Specifications of parts of the building.
General requirements regarding the plot
Building should not be constructed where
Land with refuse.
Plots with big pits.
Floodable areas.
Plot with a slope of more than 45 degrees.
Coastal areas.
Sl
no
Type of line
Vertical
clearance
Horizontal
clearance
1
Low and medium
voltage lines
2.4 m
1.2 m
2
Up to 33 kV lines
3.7 m
1.8 m
3
More than 33 kV
3.7 m +0.3
m for every
additional
33 kV.
1.8 m + 0.3
m for every
additional
33 kV.
Exterior and interior open air space
for building upto 10m height
Minimum front yard-3m
Minimum rear yard-2m
1.2 m on one side and 1 m on other side
0.5 m increase in every 3 m height.
Building above 4 storeys, a minimum open space of 5
m is to be provided.
The minimum distance from the centreline of street
to the building should be 4.5 m.
Minimum plot size-12 m x 6 m.
Front yard-3 m.
Rear yard-2 m.
One side-1.2 m.
Other side-1 m.
Interior open air space
A closed room should have an interior open space of
2.4 m width.
If the total height of the building is less than 7m, then
the interior open space shall have 1.5 m width.
Coverage & Floor area ratio
Plot area-Area enclosed b\w the boundaries of plot.
Plinth area-Area of the building at the plinth level.
Floor area-Built up area of the building at any floor
level.
Carpet area-Usable floor area.
Coverage-Maximum area on any floor of the building
excluding cantilevered open balconies, garden,
compound wall, gate, uncovered staircase etc.
Floor Area Ratio (FAR)= Total floor area on all
floors/Plot area.
where
Total floor area = total built up area in all floors
excluding parking area
Provision of size, height & ventilation of
rooms
Max height of building Minimum height of a habitable room The area of a habitable room-
Openings Lighted Ventilation of kitchen.
Area of bathroom & area of latrines
Max height of building- 1.2 x road width+2 x front
yard
Minimum height of a habitable room-3 /2.4m
The area of a habitable room-9.5 m2(min width –
2.4m)
Openings -sufficient no to ensure direct admission
of light and air – doors,windows and ventilators .
Not assumed lighted – if the portion of the room
7.5m away from the opening
Kitchen – ventilated according to the stipulated
standards.
Suitable openings for the escape of smoke and heated
air.
Bathroom area
- min 1.5 sq.m(1.1 m width min)
Latrines – 1.1 sq.m min with one side 1m