Install Detail - Choose and Book
Download
Report
Transcript Install Detail - Choose and Book
Choose and Book
Installing Security Broker (IA) client
Installing Security Broker (IA) client
• Pre-Requisites
• Installation
• Testing
• Uninstalling
• Upgrading
Pre-Requisites before installation
Network Connectivity
Check spine authentication page
https://gas.national.ncrs.nhs.uk/login/auth
activate
telnet nww.ebs.ncrs.nhs.uk 443
Firewall ports opened – http / https
Bypassing proxy servers recommended
IA compliant PC
Compliant PC
Windows 98 SE
Minimum Platform
Requirement
Processor 266Mhz
RAM 128Mb
Browser Version Internet Explorer 6.0 (SP1)
Smartcard Device See following section
Windows Service Pack n/a
Compliant PC
Windows NT 4
Minimum Platform
Requirement
Processor 266Mhz
RAM 128Mb
Browser Version Internet Explorer 6.0 (SP1)
Smartcard Device See following section
Windows Service Pack SP6
Compliant PC
Windows 2000
Minimum Platform
Requirement
Processor 500Mhz
RAM 256Mb
Browser Version Internet Explorer 6.0 (SP1)
Smartcard Device See following section
Windows Service Pack SP4
Compliant PC
Windows XP Professional
Minimum Platform
Requirement
Processor 500Mhz
RAM 256Mb
Browser Version Internet Explorer 6.0 (SP1)
Smartcard Device See following section
Windows Service Pack SP1
Compliant PC
Integrated client (e.g. Emis) may require
higher CPU and memory specifications
Anti-Virus and Anti-Spyware software
recommended
A Smart card reader, either USB or serial
(winNT), with appropriate drivers
Compliant Smart Card Readers
Gemplus PC Twin Reader
Gemplus GemPC 430 Reader (does not
work on NT 4)
Omnikey 3121 USB Reader
Dell keyboard integrated smart card
readers
SCM card readers
HP keyboard integrated card reader
Fujitsu keyboard integrated card reader
Compliant PC
Adobe Acrobat Reader 5 as minimum
An account with permissions to install software
and edit the registry (local administrator)
New Client x Old Client
The new version of the IA client (V7_8_0) can
be used for all new installations but is not a
required upgrade as the previous version
(V7_1_0) continues to be supported
The newer version has some performance and
stability improvements and contains an NHS
disclaimer. If upgrading the old version must
be uninstalled first
Summary Installation Process Flow
Ensure all Internet Explorer 6 SP1 cumulative
update patches and fixes have been installed
Connect standalone smartcard reader (or USB
Keyboard with built-in Smartcard reader) and
install drivers
IA installation pack downloaded from
http://nww.connectingforhealth.nhs.uk/implement
ation/deployment/downloads. Unzip to a
temporary location and run “iainstaller_1_0.exe”
Run the appropriate auto-installer from
C:\iainstaller\install
Continued
Summary Installation Process Flow
Add Trusted sites fix and create a CaB desktop
icon
Remove role profile screen if required
Copy CaB files to Java folder if multiple Java
versions installed
Reboot
Test access
Install Summary
Uninstall previous client
IE 6 SP1 patches and fixes have been installed
Connect smartcard reader-Install drivers
Download install pack, run “iainstaller_1_0.exe”
Run auto-installer from C:\iainstaller\install
Add Trusted sites fix
Create a CaB desktop icon
Remove role profile screen if required
Copy CaB files to Java folder if multiple Java versions
installed
Reboot
Test access
Install Detail
Connect the USB card reader install drivers
Drivers for the GemPlus Twin card reader are
installed as part of the IA installation pack. Other
card readers including the Omnikey 3121 require
additional drivers to be installed
Drivers for the Omnikey 3121 are contained
within the IA installation pack but must be
installed separately
Install Detail
Install the IA Client Software
Check that all previous components of the IA
are removed from the system
Extract the software to a suitable temporary
location and then run the file
iainstaller_1_0.exe
The IA Auto Installer will propose a location to
extract to dependant on its location. It is
imperative that this location is changed to
C:\iainstaller
Install Detail
Run the Installer software
From c:\iainstaller\install, run
the appropriate IA Auto
Installer file dependant on
the operating system.
NOTE: It is vital to ensure
that the installation is run
from this shortcut as the
shortcut contains parameters
to ensure the program
installs correctly.
Accept all the defaults for the
GemSafe Libraries until their
installation is complete.
Select No at this screen to
avoid interrupting the autoinstaller
Accept all the defaults for the
GemAuthenticate Client until
its installation is complete.
Accept all the defaults until
the completion of the Java
Installation
Click No at this screen to
avoid interrupting the autoinstaller
Click No to reboot the
system – the auto-installer
has finished successfully.
Install Detail
Install IE Trusted Sites Fix
Both the old and new IA Installer only adds
trusted sites to the HK_CURRENT_USER
hive. As a result, only the account logged on
during installation has the required trusted
sites added
reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk" /f
reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\nww.ebs.ncrs" /f
reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\portal.national.ncrs" /f
reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\nww.ebs.ncrs" /v https /t
REG_DWORD /D 2 /f
reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\portal.national.ncrs" /v
https /t REG_DWORD /D 2 /f
Install Detail
Adding CaB Shortcut Icon
Create a new desktop shortcut to the CaB
website:- https://nww.ebs.ncrs.nhs.uk
Copy this shortcut to :- “c:\Documents and
Settings\All Users\Desktop” – OS dependent
Install Detail
Remove role profile screen (old client)
Run C:\Program Files\Syntegra\Device Identification
Logger\tktmoncfg.exe. Remove last 4 lines of code.
Install Detail
Remove role profile screen (new client)
Install Detail
Disabling Java Automatic Updates
Run “JVM Settings.reg” in the C:\iainstaller\JVM
directory if Java still auto updating after
installation
Install Detail
Multiple Java Installations
Copy “c:\Program Files\gemplus\gac\GATicket.jar” to
“c:\Program Files\Java\Java_folder\lib\applet” folder
Copy “c:\Program Files\gemplus\gac\TicketApiDll.dll” to
“c:\Program Files\Java\Java_folder\lib\ext\x86” folder
Copy “c:\iainstaller\JVM\java.policy” to
“c:\Program Files\Java\Java_folder\lib\security” folder
Install Detail
Testing CaB Access
1. Insert Smartcard and enter passcode
Testing CaB Access
2. Set Session Role
Testing CaB Access
3. Select Role and/or begin using CaB
Uninstalling the IA client software
•
•
•
•
continued
Run the IA Uninstaller shortcut in the
c:\iainstaller\install directory. You should
answer NO to any request to reboot the PC
until the process complete confirmation box
End the tktmon.exe process from task manager
(old client)
Check control panel to ensure all IA
components have been removed
Remove installation directories
Uninstalling the IA client Software
Device Identification Logger
Gem Authenticate Client V.3.9.1
GemPlus Smart Card Reader Tools
GemSafe Libraries 3.1
Java 2 Runtime Environment ,SE V 1.4.2_04
Remove C:\Program Files\Syntegra folder
Remove C:\Program Files\Gemplus folder
Remove C:\TicketAPI folder
Remove C:\Program Files\Java\j2re1.4.2_04
folder
Upgrading the IA Software
•
•
•
•
•
Delete the old c:\iainstaller directory
Extract the new IA installation software to
c:\iainstaller
Run the Remove Old IA shortcut in the
c:\iainstaller\install directory
Check the control panel to ensure all old IA
components have been removed
Run the appropriate IA Auto Installer file from the
c:\iainstaller\install directory
Further Information
This document is provided as a supplement to
IG B 0103_21 Installation and Configuration
Guide - Security Broker (IA) Client and the
Choose and Book Install Reference v3.0
Document which is on the Implementation
website –
http://nww.connectingforhealth.nhs.uk/implement
ation/deployment/downloads