HQM01 Test Results Preliminary
Download
Report
Transcript HQM01 Test Results Preliminary
HQ02 TEST SUMMARY
(PRELIMINARY)
June 28, 2013
FERMILAB
2
HQ02 Test at Fermilab
First HQ02 magnet test at Fermilab
HQ coils #12, #13 and #15 tested previously in a “mirror” structure
HQ02 arrived fully assembled and instrumented
Modifications required to the suspension system used at VMTF
Minor modifications required for the cable pigtails
Cable pigtails
End suspension plate
3
HQ02 Test at Fermilab
15 kA Header assembly was used in this test with
lambda plate for 1.9 K test
o 82% of SSL at 1.9 K and 92% of SSL at 4.5 K
o Field quality measurements at 1.9 K
Main test goals:
o Quench performance study within the power supply limits
o Ramp rate dependence study
o Temperature dependence study
o Field quality measurements
o Quench protection study
Test plan, developed together by members of the
participant laboratories, may serve as a first step
toward the future test protocol
o Preliminary test results or any change in the test plan
were discussed at the video or phone meetings
4
HQ02 Test at Fermilab
Coils #15, #16, #17 and #20 with improved design
0.778-mm diameter Nb3Sn RRP strand of 108/127 sub-element design
o Additional space was provided in the tooling cavity
o Improved coil and heater insulation
o 25-µm thick, 8-mm wide Stainless Steel (SS) core
o
Coil #15 previously tested in a mirror structure at Fermilab: 97% of
SSL was reached at 4.5 K and 94% of SSL - at ~2.2 K
Coils #16, #17 and #20 never tested or loaded previously
60 mΩ dump resistor used for the stored energy extraction
16 protection heaters were combined in 4 individual groups
connected to a separate power unit
5
HQ02 Short Sample Limit
SSL based on extracted samples: 16.4 / 18.3 kA at 4.6 / 1.9 K (coil #17)
A. Godeke,
April 4, 2013
6
HQ02 voltage tap system
10 VT on both the inner and outer coil layers
7
HQ02 quench training
Regular ramp rate of 20 A/s was used for quench training
4.5 K
1.9 K
2.1 - 4.5 K
10 A/s 5 A/s
MIITs study
80% of SSL (150 T/m)
92% of SSL
8
HQ02 ramp rate dependence study
No quenches when ramping down from 14605 A at 13-300 A/s
All ramp rate quenches at 200 A/s and more initiated in coil #17
9
HQ02 temperature dependence study
All ramps performed at 20 A/s ramp rate
10
HQ02 RRR measurements (cont’d)
Measured RRR in HQ02 coils:
Coil #15: 80
Coil #16: 90
Coil #17: 130
Coil #20: 140
A. Godeke. April 4, 2013
11
HQ02 RRR measurements (cont’d)
12
HQ02 QI study
13
HQ02 QI study (cont’d)
14
OL to IL quench propagation
15
HQ02 inductance measurements
16
HQ02 quench back measurements
60 mΩ dump resistor
17
HQ02 Test Summary
HQ02 magnet with the new generation coils successfully was tested at
Fermilab
The magnet reached 15 kA power supply limit at all temperatures from 1.9 K
(82% of SSL) to 4.5 K (92% of SSL)
All training quenches initiated in the high field area (pole turn segments)
At both 4.5 K and 1.9 K no quenches were observed up to the 15 kA power
supply limit for ramp rates below 200 A/s (1.9 K) and 150 A/s (4.5 K)
No quenches were observed during down ramps from 14.6 kA for ramp rates
20-300 A/s
Holding current tests performed both at 4.5 K and 1.9 K. 14.6 kA current was
held for 30 min. Later on magnetic measurements were performed at this
current for several hours
Field quality measurements were performed at 1.9 K and 4.6 K (J. DiMarco
and X. Wang)
Quench protection study performed at 1.9 K and 4.5 K (T. Salmi)
18
Backup slides
19
OL to IL quench propagation