Conducting an Energy Usage Study for a Commercial Office

Download Report

Transcript Conducting an Energy Usage Study for a Commercial Office

Panida Boonyaritdachochai
The 11th Annual PQSynergy International Conference
Le Meridien, Chiang Mai
19-21 September 2011
18 July 2015
1
 Assumption
 Light Sensor Technology
 Monitoring Result
 Cost Assessment
 Conclusions
18 July 2015
2
 Location:
Power Quality (Thailand) Co.,
Ramkamhaeng Rd. Soi 90, Bangkok, Thailand.
Ltd,
 Power Supply: Metropolitan Electricity Authority (MEA)
 Lamp Technology: 2 Fluorescent Lamps
 Two cases in this study.
 Operation Time of Light Sensor


Turn On Lamp: 18.00
Turn Off Lamp: 06.00
18 July 2015
3
 A light dependent resistor (LDR) or photoresistor is a resistor
whose resistance decreases with increasing incident light intensity.
 A photoresistor is made of a
high resistance semiconductor. If
light falling on the device is of high enough frequency, photons absorbed
by the semiconductor give bound electrons enough energy to jump into
the conduction band.
18 July 2015
4
18 July 2015
5
 This case study uses “Energy Platform 1” from
Dranetz.
18 July 2015
6
18 July 2015
7
RMS variation
18 July 2015
8
Waveform Samples
18 July 2015
9
18 July 2015
10
18 July 2015
11
Avg value is used to
calculate
the electricity cost.
18 July 2015
12
 From the MEA monthly bill, our revenue
meter read as 635 kWh with billing 2,415.70
Baht. So, the average cost is 3.8 Baht/kWh.
 As an hour measuring of energy consumption
has average by 0.152 kWh, so the energy
consumption cost is approximately
(3.8*0.152) ≈ 0.5 Baht.
18 July 2015
13
 Case I: 2 FL lamps without light sensor
24 hours are assumed for turn on the lamps.
 The monthly bill will be (0.5*24*30) = 360 Baht.

 Case II: 2 FL lamps with light sensor
The lamps are turned on for 12 hours (6 pm – 6 am).
 The monthly bill will be (0.5*12*30) = 180 Baht.

 The cost reduction is 180 Baht/month.
18 July 2015
14
 Light sensor cost is about 300 Baht.
 The 3 years warrantee
 Specification 1500 W
 Reference: (http://eofficethailand.com/product.php?id_product=1607)
 Fluorescent Lamps
 The cost of FL lamps is not considered due to it is the
same for both cases study.
 The life cycle is 12,00o hours ≈ 1.3 year. This is
advantageous for extended life.
 Installation Labor is 300 Baht referred by an
electrical worker.
18 July 2015
15
 Total investment cost of light sensor is
Labor
Light Sensor
(300 + 300) = 600 Baht.
 The electricity reduction cost is 180 baht/month
 The payback period can be calculated from
(180 x 3) = 540 Baht
(180 x 4) = 720 Baht
 Saved our money for a year as (180 x 8) =
!!!!! 1,440 Baht !!!!!
18 July 2015
16
 The light sensor type LDR is “Energy Saving Technology”
for security, outdoor or landscape lighting system.
 As a simplified case study, it is less than 5 months for
payback period.
 A study of energy saving is influenced by many factors i.e.






type of lamp or sensor technology
electrical design
life cycle of technology
electricity tariff
Labor cost
etc
18 July 2015
17
[email protected]
18 July 2015
18