Aucun titre de diapositive

Download Report

Transcript Aucun titre de diapositive

Power Factor Correction and
Filtering : LV offer
Give oxygen to your
electrical network
VARPLUS² :
the range
Give Oxygen to your electrical network
 VARPLUS² :
 A fully modular offer with only one size for installation and
connection
 Maximum power per unit : 20 kvar at 50 Hz
 Installation in all positions
 Possibility of wiring connection at 360°
 50 Hz or 60 Hz
 Additional options :

IP 20/42 protection kit
CEF - Marketing – 2007 – R.Fontanes

2 bus bars set connection between capacitors
2
VARPLUS² :
the range
Give Liberty to your installation
Assembly of
capacitors
Connection with bus bars
kit or you can build your
own bus bars if you prefer
Additional IP 20/42
protection kit
CEF - Marketing – 2007 – R.Fontanes
3
VARPLUS² :
the range
Give the right specifications
Rated voltage of
the Varplus²
Network
230V
50 Hz
60 Hz
400/415V
240V
415V
480V
525V
550V
690V
690V
230V
240V
400/415V
415V
480V
525V
550V
690V
690V
 You can always use a capacitor with an upper voltage than your application if you want to.
CEF - Marketing – 2007 – R.Fontanes
4
VARPLUS² :
the range
Give the right specifications
Example : for a
400V-50Hz network
Slightly polluted
network
Gh/Sn  15%
CLASSIC
Components :
Varplus²
capacitors rated
at 415V
CEF - Marketing – 2007 – R.Fontanes
Polluted network
15%< Gh/Sn 25%
Highly polluted
network
25%< Gh/Sn 50%
COMFORT
HARMONY
Components :
Components :
Varplus² capacitors
rated at 480V
Varplus² capacitors
rated at 480V
+
Detuned reactors
(135Hz, 190Hz or
215Hz)
5
VARPLUS² :
differences with Varplus M
Give Oxygen to your electrical network
Varplus M1
Varplus²
5 à 15 kvar
Varplus Varplus² Difference
210
219
+9
218
220
+2
116
114,7
-1,3
Height (mm)
Width (mm)
Depth (mm) (*)
(*) with cable connection
2 Varplus M1
Varplus²
20 kvar
Varplus Varplus² Difference
210
219
+9
218
220
+2
211,5
114,7
-96,8
Height (mm)
Width (mm)
Depth (mm) (*)
(*) with cable connection
CEF - Marketing – 2007 – R.Fontanes
6
VARPLUS² :
differences with Varplus M
Give Oxygen to your electrical network
Varplus M4
Varplus²
+ bus bar kit (option)
50 kvar
Varplus Varplus² Difference
210
219
+9
218
220
+2
350
308,7
-41,3
Height (mm)
Width (mm)
Depth (mm) (*)
(*) with cable connection
Varplus M4
Varplus²
+ bus bar kit (option)
60 kvar
Varplus Varplus² Difference
210
219
+9
218
220
+2
350
308,7
-41,3
Height (mm)
Width (mm)
Depth (mm) (*)
(*) with cable connection
CEF - Marketing – 2007 – R.Fontanes
7
VARPLUS² :
Give compliance with standards
 IEC compliance
 IEC 60831 - 1
 IEC 60831 - 2
 UL compliance
 UL 810
 CSA compliance
 CSA 22-2 N°190
CEF - Marketing – 2007 – R.Fontanes
8
VARPLUS² :
the benefits
Give liberty to Panel Builders
 Very large choice of positions to install the new VARPLUS² capacitor
CEF - Marketing – 2007 – R.Fontanes
9
VARPLUS² :
the benefits
Give liberty to Panel Builders
 No limit for the assembly of capacitors
 example with 120 kvar:
There are 3 conditions to respect :
CEF - Marketing – 2007 – R.Fontanes

Adapted bus bar section is
expected to connect the capacitor
assemblies shown beside

Minimum space of 25 mm is
expected between 2 groups of
capacitors (see the figure beside)

According to “Ventilation” chapter,
specific precautions must be taken
in order to not exceed temperature
category : class D inside the cubicle
1
0
VARPLUS² :
the benefits
Give simplicity to Panel Builders
 With VARPLUS², no earth connection needed
 Fixation holes allow to have an easy and firm fixation with 2 M6
Screws :
Fixation holes
 Connection on the top of the capacitor : very easy to access
CEF - Marketing – 2007 – R.Fontanes
1
1
VARPLUS² :
the benefits
Give simplicity to Panel Builders
 Assembly of several capacitors is fast and easy :
 Wiring connection at 360°, and on the top of the capacitor (easy to
access) :
CEF - Marketing – 2007 – R.Fontanes
1
2
VARPLUS² :
the benefits
Give liberty to Distributors
 The fully modularity of the new VARPLUS² will give you a lot of
flexibility in your stock management.
VARPLUS²
VARPLUS M
CEF - Marketing – 2007 – R.Fontanes
1 unique size
1
3
VARPLUS² :
the benefits
Give liberty to Distributors
 VARPLUS², thanks to the assembly game, will allow you to cover
all the power ratings you could need, depending on the voltage,
frequency and harmonic pollution level of the network.
 The fully modularity of the new capacitors will give high flexibility
for stock management, example :
Power rating
15 kvar
20 kvar
30 kvar
40 kvar
50 kvar
60 kvar
TOTAL

CEF - Marketing – 2007 – R.Fontanes
Varplus M references
B
2 * A (10kvar)
2*B
2*B+A
C
D
4 references
Varplus² references
E
F
2*E
2*F
2*E+F
3*F
2 references
With less references you can cover all your needs
1
4
VARPLUS² :
the benefits
Give peace of mind to End Users
 The life duration of VARPLUS² is 15 years (130 000 hours).
 Discharge resistor is already inside the capacitor :
 Resistor reduces voltage to less than 50V in 1 minute
 it can be used in an automatic power factor
correction bank without any additional discharge devices.
CEF - Marketing – 2007 – R.Fontanes
1
5
VARPLUS² :
the benefits
Give peace of mind to End Users
 A new production line especially for VARPLUS² : fully
automated line, no risks of human errors
 Robots for a high quality :
CEF - Marketing – 2007 – R.Fontanes
 An automatic control
at each step of production :
1
6
VARPLUS² :
the benefits
Give safety to End Users
terminals
internal fuse
 The mechanical resistance of the envelop has been
multiplied by 2 compare to VARPLUS M.
metalic disk
overpressure
below
resin
 High withstand to the fire => self extinguishing (V0
plastic to fulfil the UL compliance)
plastic case
coil
gas release channel
CEF - Marketing – 2007 – R.Fontanes
 A High Quality protection system :
VARPLUS² is the one capacitor to use this technology to
prevent 100% of the eventual defaults
1
7
VARPLUS² :
protection system
Give safety to End Users
•
Against internal defaults (with a low current),
thanks to the overpressure system
Dielectric losses its self healing
properties
Gas pressure increases slightly
and reaches the below.
The below rise
The metallic disc short circuits the
terminals across the fuse.
The faulty capacitor is out of
service.
CEF - Marketing – 2007 – R.Fontanes
•
Against external defaults (with high current),
thanks to the HRC fuse
 The fuse protects against
high current faults > I fuse
 It operates for high current
short time faults
1
8
VARPLUS²
Give involvement to the environment
 The consumed energy has been decreased by 10% compare to
VARPLUS M: VARPLUS² total losses < 0,5 Watt/kvar (discharge
resistor included).
 VARPLUS² is ROHS (Restriction Of Hazardous Substances)
compliant. It means that VARPLUS² doesn’t contain any substances with
concentrations exceeding the limits fixed by the ROHS Organism.
 Involvement to the environment (ISO 14001) :
CEF - Marketing – 2007 – R.Fontanes

VARPLUS² is a dry technology : free of liquids.

VARPLUS² is environmentally friendly.
1
9
VARPLUS² : accessories
Give a fully compatibility with VARPLUS
 Foot print for fixing is the same
 Extension kit :
A kit to extend your installation with new
VARPLUS² beside VARPLUS M capacitors is
available.
CEF - Marketing – 2007 – R.Fontanes
2
0
VARPACT :
Give Oxygen to your electrical network
 Why the module : how does it work, what is the interest ?
Loose components
Panel builder
Capacitors
supplier
Modules
Advantages
Modules
Panel builder
VARPACT
Contactors supplier
Wiring supplier
Protection supplier
Assemblyof
components in the
cubicle + study of the
engineering department
to use the right
component.
Electrical tests to do in order to check all the connections
CEF - Marketing – 2007 – R.Fontanes
Time saving
and suppliers
management
much easier
Installation of
VARPACT inside the
cubicle
All the Varpact modules have been tested
inside Schneider manufacturing plant.
Time saving
and easier to
install : no
need of an
engineering
department
Time saving
and more safe
2
1
VARPACT :
the range
Give Oxygen to your electrical network
 VARPACT :
 A pre-wired assembly, ready to be installed in the
bank.
 Capacitors, commutation function, protection
function are already incorporated inside VARPACT
 It will allow you to build your capacitors bank in a
very short time.
 Maximum power for 1 module : 120 kvar at 50 Hz
 Tested at 100% inside Schneider plant

CEF - Marketing – 2007 – R.Fontanes
With or without bus bars : you have the choice.
2
2
VARPACT :
the range
Give Oxygen to your electrical network

 VARPACT options :
Circuit breaker option* for Classic and
Comfort range (not installed) :



Connection module :
Extensions pieces for cubicle (W=650,700,800 mm) :
Fastening crosspieces :
* The circuit breaker is always installed on the Varpact Harmony modules (to protect the Detuned reactor)
CEF - Marketing – 2007 – R.Fontanes
2
3
VARPACT :
the range
Give Oxygen to your electrical network
 VARPACT Classic and Comfort :
CEF - Marketing – 2007 – R.Fontanes
2
4
VARPACT :
the range
Give Oxygen to your electrical network
 VARPACT Harmony :
CEF - Marketing – 2007 – R.Fontanes
2
5
VARPACT :
the range
Give the right specifications
400V-50Hz
networks
In any case, it is recommended
to make measurements at site
in order to validate the final
solution
Slightly polluted
network
Gh/Sn  15%
Varpact
Classic
15%< Gh/Sn 25%
Varpact
Comfort
Highly polluted
network
25%< Gh/Sn 50%
Varpact
Harmony
• Simple or
double steps
• Simple or double
steps
• Simple or double
steps
• From 12,5 to
120 kvar
• From 15 to 90 kvar
• From 12,5 to 50 kvar
• Inside : Varplus²
rated at 480V
• Inside : Varplus²
rated at 480V +
Detuned Reactor (135,
190 or 215 Hz)
• Inside : Varplus²
rated at 415V
CEF - Marketing – 2007 – R.Fontanes
Polluted network
2
6
VARPACT :
installation
Give the right specifications
 VARPACT can be installed in all the following type of banks :
 Prisma, Prisma Plus
 Universal
 Horizontal mounting in functional or universal bank, depth D = 400
or 500 mm :
 in cubicle (width W=600 mm), using fastening crosspieces
 in cubicle (width W=650, 700, 800 mm), using fastening
crosspieces and extension pieces
 Vertical fastening every 300 mm (5 modules maximum) directly to
cubicles uprights using sliding crosspieces or to intermediate
upright support.
 Control circuit power supply : 230V, 50 Hz
CEF - Marketing – 2007 – R.Fontanes
2
7
VARPACT :
installation
Give the right specifications
 Installation of modules in the cubicle :

CEF - Marketing – 2007 – R.Fontanes
Varpact with bus
bars :

Varpact without
bus bars :
2
8
VARPACT
Give compliance with standards
 International standards IEC
 IEC 60439 - 1
 IEC 61921
 European standards
 EN 60439 - 1
CEF - Marketing – 2007 – R.Fontanes
2
9
VARPACT :
benefits
Give simplicity to the Panel Builders
 VARPACT modules allow to assemble a power factor correction
cubicle quickly and easily :
 Connection points are decreased
CEF - Marketing – 2007 – R.Fontanes

Bus bars option --> Easier installation (connection)

Logistic : 1 unique product to order instead of many products
(capacitors, wires, contactors, protection…)

You don ’t need to have an engineering department to calculate
the right components to use (wires size…)

Fastening crosspieces to install VARPACT in the cubicle

VARPACT is tested at 100% inside the manufacturing plant
3
0
VARPACT :
benefits
Give peace of mind to End Users
 Life duration of VARPACT is 15 years (130 000 hours)
 Safety of the operator during the maintenance operation thanks to the
internal discharge resistor.
 Protection against direct contacts during the maintenance thanks to the
protection plate.
 Decrease of hot points on the module, and decrease of the temperature
inside cubicles compare to P400 modules.
 Losses reduction = less overheating = more power inside 1 cubicle :
 600 kvar / column for the Classic range (450 kvar in the past)
 450 kvar / column for the Comfort range (405 kvar in the past)
 250 kvar / column for the Harmony range (like in the past)
CEF - Marketing – 2007 – R.Fontanes
3
1
VARPACT :
accessories
Give a fully compatibility with P400 modules
 Retrofit kits exist. It allows to replace former modules by VARPACT
in the following case :
CEF - Marketing – 2007 – R.Fontanes

Retrofit kit to replace a P400 module by a VARPACT module
inside a Prisma or Prisma Plus cubicle

Retrofit kit to replace a P400 SAH module by a VARPACT
module inside a Prisma or Prisma Plus cubicle

Retrofit kit to replace a P400 module by a VARPACT module
inside a Rectimat2
3
2
New Power Factor Correction offer
Give Oxygen to your electrical network
 VARPLUS² and VARPACT will give to your electrical installation, its
maximum energy efficiency :
> To erase expense on reactive power
> Higher transmission capacities for effective power
> Environment involvement thanks to a lower electrical
consumption
> Improvement of power quality
> Reducing the operating costs
 The installation of VARPLUS² or VARPACT capacitors means :
> a static system, don’t need maintenance
> Life duration of 15 years
> Fast Return on Investment (between 1 and 3 years)
CEF - Marketing – 2007 – R.Fontanes
3
3