Aucun titre de diapositive
Download
Report
Transcript Aucun titre de diapositive
LV Compensation and Filtering
Give Oxygen to your electrical network
Components
Modules
CEF - Marketing - 2006
Varplus² capacitors
Varlogic N controller
Detuned Reactor
LC1-D contactors
Varpact modules
1
VARPLUS² :
the range
Give Oxygen to your electrical network
VARPLUS² :
A fully modular offer with only one size for installation and
connection
Maximum power per unit : 20 kvar at 50 Hz
Installation in all positions
Possibility of wiring connection at 360°
50 Hz or 60 Hz
Additional options :
CEF - Marketing - 2006
IP 20/42 protection kit
2 bus bars set connection between capacitors
2
VARPLUS² :
the range
Give Oxygen to your electrical network
Assembly of
capacitors
Connection with bus bars
kit or you can build your
own bus bars if you prefer
Additional IP 20/42
protection kit
CEF - Marketing - 2006
3
Varlogic N controller
Give Oxygen to your electrical network
Varlogic NR6 / NR12 :
Analyse and inform about data of the network
CEF - Marketing - 2006
Manage the reactive power to obtain the targeted cosφ
Check the proper working of the system
Easy use thanks to the auto setting
Simple reading of the main measures
4
Varlogic N controller
Give Oxygen to your electrical network
A higher level of expertness : more than the NR6/NR12 Varlogic,
the NRC12 Varlogic brings :
More measures : total current harmonic distortion THD(I),
voltage and current harmonic spectrum
Answer to specific applications : 4 quadrant operation for
generator application, possibility of dual cos j target, medium
voltage application, fixed step configuration programming
Simple interface with a graphic screen, help menu
A communicating controller
Communication RS485 Modbus set as an option
CEF - Marketing - 2006
5
Detuned Reactor
Give Oxygen to your electrical network
Detuned Reactors :
The detuned reactors are 3-phase inductances, designed to protect
the capacitors and prevent amplification of the harmonics present on
the network.
CEF - Marketing - 2006
The range is going from 6 to 100 kvar, for 400/415V network
voltage at 50 Hz. Three tuning orders are available (135, 190 et
215 Hz)
Safety thanks to the temperature sensor (allow the protection)
Dry type very few maintenance
6
LC1 – D contactors
Give Oxygen to your electrical network
LC1-D contactors :
The use of standard contactors may compromise the safety of
persons and installations (capacitor control is accompanied by
transient operating conditions resulting from the capacitor load
which, amongst other thing, generates a very high overcurrent
equivalent to a short-circuit of short duration)
CEF - Marketing - 2006
The LC1-D K contactors are specially designed for capacitor
control.
They are fitted with a contact block allowing the current to pass
on closing and with damping resistors limiting the current on
energisation.
7
VARPACT :
the range
Give Oxygen to your electrical network
VARPACT :
A pre-wired assembly, ready to be installed in the
bank.
Capacitors, commutation function, protection
function are already incorporated inside VARPACT
It will allow you to build your capacitors bank in a
very short time.
Maximum power for 1 module : 120 kvar at 50 Hz
Tested at 100% inside Schneider plant
CEF - Marketing - 2006
With or without bus bars : you have the choice.
8
VARPACT :
installation
Give the right specifications
Installation of modules in the cubicle :
CEF - Marketing - 2006
Varpact with bus
bars :
Varpact without
bus bars :
9