MASTER Fire Pump Controllers
Are Engineered to the Highest
Standards in the Industry







Instant-On circuitry
Restart time delay
Modular Mother board
All printed circuits are
enclosed in a steel card cage
Diagnostic Plug and LEDs
Triple redundant control
transformers
35% voltage drop
Pride in Workmanship
Worldwide
Features That Make MC Series Fire
Pump Controllers a Smart Choice

No field Programming
 LED’s and SPDT contacts for visual
and remote monitoring of alarms
 Vertically mounted ISO SW and CB
 Digital display readout
 Single phase protection
 Independent pressure and alarm
recorder
 DC Shunt trip
Pride in Workmanship
Worldwide
MC Features Continued
Restart Time Delay
Controllers utilize a restart timer to delay the
instantaneous re-start of
the controller. This allows
electromagnetic fields in
the motor to decay.
Pride in Workmanship
Worldwide
MC Features Continued
Control Chassis
Control chassis has
Diagnostic LEDs, latched
connectors and a steel card
cage for mechanical
protection of printed circuit
boards
Pride in Workmanship
Worldwide
MC Features Continued
Triple Redundant Control Transformers
Triple Redundant
control transformers
privide full control
power even if a
phase is lost
Pride in Workmanship
Worldwide
MC Features Continued
35% Voltage Drop
Controllers will
continue to operate if
the voltage drops by as
much as 35% of rated
voltage. This can be
critical when starting
the fire pump on
emergency power.
Model MCP
Pride in Workmanship
Worldwide
MC Features Continued
Isolation Switch and Circuit Breaker
Vertically mounted
Isolation Switch and
Circuit Breaker with
Separate operating
handles and
interlock.
Pride in Workmanship
Worldwide
MC Features Continued
Door Display
Through the door digital
display reads out
voltages, phase currents
and pressure
Pride in Workmanship
Worldwide
MC Features Continued
DR2500 Paperless Pressure and Alarm Recorder
Independent digital
recorder saves the latest
2500 pressure points and
350 alarm points into a
separate permanent
memory buffers
Pride in Workmanship
Worldwide
MC Features Continued
DR2500 Paperless Pressure and Alarm Recorder
The DR2500 is
specifically designed
to communicate
through an RS-232
serial port directly to
a lap-top computer or
a network server
Pride in Workmanship
Worldwide
MC Features Continued
DR2500 Paperless Pressure and Alarm Recorder
Data may be
downloaded by using
any terminal emulator
program such as
Terminal, Hyperterm,
etc.
Pride in Workmanship
Worldwide
MC Features Continued
DR2500 Paperless Pressure and Alarm Recorder
DR2500 control menu
Pride in Workmanship
Worldwide
MC Features Continued
DR2500 Paperless Pressure and Alarm Recorder
Retrieved
data
Pride in Workmanship
Worldwide
MC Features Continued
DC Shunt Trip
Controllers use a DC
shunt trip coil
powered from all 3
phases. The locked
rotor protector will
still operate under a
single phase
condition.
Pride in Workmanship
Worldwide
Motor Starting Types

Across-the-line
 Part-winding
 Primary reactor
 Wye-delta (open)
 Wye-delta (closed)
 Soft Start
 Autotransormer
Pride in Workmanship
Worldwide
Motor Starting Types Continued
Reactor Comparison

Reactor uses a standard electric motor
 Reduces complexity of field wiring - wired
same as across the line
 Low Power Factor makes the reactor ideal
for gen-set applications
Pride in Workmanship
Worldwide
Motor Starting Types Continued
Fire Pump Starting Type Characteristics
Pride in Workmanship
Worldwide
Motor Starting Types Continued
Leading Phase Monitor™

Used on Wye-Delta (open) controllers
 Reduces open circuit transient to closed
circuit levels
 Allows you to use Wye-Delta (open) as an
option to Wye-Delta (closed)
Pride in Workmanship
Worldwide
Motor Starting Types Continued
Leading Phase Monitor™
Wye-Delta Transition Transients (typical)
Closing the Delta contactor
(run) with closing voltage
leading the Wye contactor
(start) gives you closing
currents about the same as
closed transition controllers
Pride in Workmanship
Worldwide
Thank You!