Welcome to the new GE PowerPoint template!

Download Report

Transcript Welcome to the new GE PowerPoint template!

Match UPS
Product Management
July 2004
Contents
Range
Topology
Unique Selling Points
Key Features
Accessories
Applications
Match UPS
Product Management
July 29th, 2004
“Even a moment’s disruption can have devastating effects on
power sensitive customers such as internet service providers,
data centres, wireless telecommunications networks, on line
traders, computer chip manufacturers and medical research
centres. For these customers, power disruptions can result in data
corruption, burned circuit boards, component damage, file
corruption and lost customers.” - “Electrical Power Interruption Cost
Estimates for Individual Industries, Sectors and US Economy” February 2002, US Dept of
Energy, Office of Power Technologies
“The system and its data can become corrupt as a result of power
failure…a UPS can protect the system if power is lost. A UPS
usually provides…temporary power which may be enough to
permit a graceful shutdown” - Special Publication 800-34 Contingency
Planning Guide for Information Technology Systems, National Institute of Standards and
Technology, June 2002
Match UPS
Product Management
July 29th, 2004
Range
Models available include
⃘ 500, 700, 1000, 1500, 2200 & 3000VA tower models
⃘ 700, 1000, 1500, 2200 & 3000VA 19inch rackmount models
⃘ Longer runtime (L) version for 700VA and 1000VA
⃘ 2200 and 3000VA with DC connector for additional batteries
⃘ Matching battery cabinets
Match UPS
Product Management
July 29th, 2004
Topology
Line Interactive
Boost
Normal
Control
Inverter
Buck
OUT
IN
Battery
AVR
Relay
Safety
Relay
Match UPS
Product Management
July 29th, 2004
Topology
A Line Interactive UPS provides:
Battery back up and voltage stabilisation
As well as providing back up power from the battery when
the mains fails, the UPS filters the mains during normal
operation, regulating the incoming voltage
Cost effective UPS protection
Lower price compared to on line UPS
Match UPS
Product Management
July 29th, 2004
Topology
A Line Interactive UPS provides:
Small break in power
During the switch from mains to battery, there is a small
loss of power to the load (typically 2-4ms, not affecting
most computer type loads)
Medium degree of protection
When compared to on line (double conversion) UPS
Match UPS
Product Management
July 29th, 2004
Unique Selling Points
Excellent High Voltage Protection
The Match UPS will protect itself and the supported
load up to 350VAC. Most UPS will damage
themselves or the load if the input voltage exceeds
300V
Low ‘Green’ Power Consumption
Compared to other line interactive UPS, the power
consumption is extremely low during normal
operation
Match UPS
Product Management
July 29th, 2004
Unique Selling Points
Optimised Sinewave Output
The output waveform is sinusoidal with a linear load,
and with a crest load is slightly flattened. This avoids
high current peaks on the electronics and the
battery, and still provides high efficiency.
This is the optimal solution between sinewave and
stepwave UPS outputs. Stepwave UPS can cause
some electronic equipment to malfunction.
Match UPS
Product Management
July 29th, 2004
Additional USPs, Match 2200 & 3000
Extremely wide input voltage window
At 165-275V (500-1500VA) and 140-305V (2200 &
3000VA), the output voltage is limited to 190-254V. This
minimises the need for battery use, extending battery
life
Battery charging even at 140VAC
Even in poor mains conditions there is a fast recovery
of battery power, increasing up time and battery life
High battery recharge current
When additional battery packs are connected, the
charger current automatically increases to 10A,
ensuring much faster recharge time
Match UPS
Product Management
July 29th, 2004
Additional USPs, Match 2200 & 3000
Deep battery calibration test
The actual battery capacity can be tested and
calibrated. This ensures the predicted runtime stays
accurate throughout the life of the UPS
Load dependent end of discharge
If the discharge time is shorter, batteries may be
discharged deeper. This features ensures maximum
runtime is is given at any load level, without the risk
of damaging the battery during longer power failures
Match UPS
Product Management
July 29th, 2004
Key Features
Automatic voltage regulation
The buck and boost function minimises battery
operation, increasing the battery life. With an inout
voltage window of 165-275V, the output voltage is
limited to 190-254V
Crest factor input acceptance 6:1
The Match is especially suited for computer loads,
and no oversizing is necessary
Match UPS
Product Management
July 29th, 2004
Key Features
Battery start (cold start)
Allows the UPS to be switched on without mains
power, for mobile applications or to perform a quick
action during a mains failure
Extended communication
RS232, SNMP and contact interface communication
(plug in options for Match 700L and above)
Match UPS
Product Management
July 29th, 2004
Key Features – Superior Battery Management
Automatic monthly battery
testing
Alerts the user that the batteries need to be replaced
Safe battery test
The UPS keeps running in normal operation over the test,
rather than switching to battery. If the battery is damaged
or empty, the load is still supported
Automatic boost charge
For areas with poor mains, ensures a faster recharge time
than with float charge only
2 hours battery recharge time
Means that loads even in very poor mains areas can be
supported more than once during a shift
Charger off at end of discharge
period
Prevents battery depletion beyond recharge capability
Lowest battery temperature
during mains operation
The electronic design of the UPS means the battery
temperature is very low, increasing battery life
No load shutdown
On battery at less than 5% load, the UPS performs an
automatic shutdown to protect the battery. This function
can be disabled
Match UPS
Product Management
July 29th, 2004
Accessories
SNMP Card
⃘ Can be used with Match 700L upwards
⃘ Presents UPS information across a network via:
⃘ SNMP Agent (one or more NMS can monitor, manage
and control the UPS)
⃘ Web Server (UPS data in HTML format, so standard internet
browser can be used to monitor UPS)
⃘ Easy installation through RS232 slot
⃘ SNMP box also available
Network Protection Software
⃘ CD packed with UPS free of charge, with intelligent
communication cable.
⃘ Simple installation
⃘ Virtually invisible operation under normal conditions
⃘ Provides a graceful shutdown of load after a lengthy mains failure
⃘ Supports all major operating systems
⃘ DataShield supplied for JAVA supported operating systems
Match UPS
Product Management
July 29th, 2004
Accessories
Relay Interface Card
⃘ Can be used with Match 700L upwards
⃘ Easily installed into CardConnect slot at rear of UPS
⃘ Provides 4 potential free contacts for:
Mains failure
General alarm
Battery low
Bypass active
and a 9 pole Sub-D connector
Manual Service Bypass
⃘ Contains a manual bypass switch
⃘ Allows for maintenance or testing of UPS with no
interference to the protected load
⃘ Pluggable as standard, but can be hardwired using the
internal terminal strip
Match UPS
Product Management
July 29th, 2004
Applications
PCs
Servers
Workstations
Hubs, switches and routers
Cash register systems (EPOS)
Fax, modem, ISDN adaptors
Match UPS
Product Management
July 29th, 2004
www.gedigitalenergy.com
Powering the digital world