MCDGV4-2 product presentation v01
Download
Report
Transcript MCDGV4-2 product presentation v01
HighPROTEC-2
MCDGV4-2 Generator Protection
with differential
Sales presentation
2015/08/10
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 1
MCDGV4 - Key Benefits
Cost savings for field service equipment and commissioning effort
Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring
Easy relay configuration achieves high service staff acceptance and
minimizes training expenses
Change tracking and plausibility check avoids parameter errors
Optimized overview by hidden protection modules in planning module
Text explanation for all parameter avoids misunderstanding
All in one protection functions by an optimized overview reduced risk of
changed customer requirements and to order a wrong devices type
Full Protection package for Differential Protection, Restricted earth fault, OC, EC, Thermal load, Inrush
detection, voltage, frequency…
Protection of generator and transformer with one device
With logic, up to 80 equations
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 2
MCDGV4 - Key Benefits
Production and maintenance flexibility
Flexible hardware covers a wide range of nominal values (Vn setting for DI, wide range power supply, wide
range voltage measuring, 1A/5A in one version)
Easy wiring at the rear side, pre wiring possible via terminal kit
All terminals are removable, including current measuring terminals
PC Tool Smart View for free
Page editor to create own pages and single lines
Easy connection between PC and Protection device via USB interface
Visualization of tripping curves graphically to get visual feedback of settings and protection concept
Look and feel over the complete HighPROTEC line -reduced training efforts
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 3
Product Ordering code - Easy to select
Basic description of Product
Generator Differential Protection with voltage,
logic and control for 6 switchgear / breaker
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 4
Meets Global Standards – for the global
market
Lloyds Register in preparation
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 5
Product Features - All in One
Protection functions, one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 6
Product Features - All in One
Protection functions, one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 7
Product Features - All in One
Supervision functions, Control and Logic - one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 8
Product Features - All in One
Optional products to enhance protection functionality
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 9
Product Features
– All in One
ANSI functional
overview
- one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 10
Product Features – Flexible Hardware
Rear side
X1
X2
X3
X4
X5 / X6
X100
X102
X103
X104
Power supply and digital inputs
Relay outputs
CT measuring board
VT measuring board
MCA4A = not used
MCA4D = add. 6 binary outputs and 8 digital inputs
Ethernet Interface RJ45, (IEC, Modbus, Profibus, DNP3)
Interface for external Temperature box URTD
Communication Interface (IEC, Modbus, Profibus, DNP3)
IRIG/ Watchdog
Design advantages
Making it easier to apply worldwide
The flexible hardware minimized
commissioning, and ordering failures
Wide range power supply
24-270VDC / 48-230VAC
Nominal voltages for the digital inputs are per
software settable
CT measurement always with 1A and 5A
VT measurement from 0V up to 800 V AC
All terminal blocks are removable,
CT Connector with integrated short circuit
device
Housing based on aluminum extrusion parts
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 11
Product Features –Temperature box URTD
Design advantages
Reduced wiring because no need to
wire all sensors to the door
Up to 12 temperature measuring
points, PT100, Ni100, NI120, Cu
Save temperature protection with
an easy setting in combination with
HighPROTEC devices for motors,
transformers and generators
Easy connection between
protection device and URTD box via
fibre optic cable (1m – 25m)
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 12
Market overview
Protection in medium voltage generator applications
Applications in different market areas:
Power generation – Protection of Generators
Steam turbine market (in combination with ATLAS or 505)
Gas turbine market
Gas and Oil engine producer / Gen Set packager
Power plants CHP
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 13
Application Example MCDGV4
The generator
Generator
protection with a
direct connection to
a busbar. At the
busbar several
generators could be
connected. The GRID
connection is at the
primary side of the
MV transformer.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
The generator
differential
protection offers
the possibility to
protect the
generator and the
transformer. The
MV busbar
connection is at
the primary side
of the
transformer.
PAGE 14
Application Example MCDGV4
Power plant with distribution system, application is functional covered by HighPROTEC devices
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 15
Application Example MCDGV4
MCDGV4 in combination with 505
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 16
Application - Control for 6 Switchgear/
breakers, design your own page
Control function up to 6 switchgears
Extended interlocking management
Switchgear timing management
Switchgear status (display Single
Line)
PC Tool – Page editor
Page editor, easy to design a single
line or a measuring page
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 17
Application Logic – Highest Flexibility
Provides logic editor
Up to 80 equitation's
Select the gate type
Assignment of 4 logic input gates
Output gates with/ without timer
Latched, Set
Reset, Inverter
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 18
Commissioning and Maintenance
Fault simulation with the integrated V-I generator without additional wiring
Force and disarm relays, simulate temperatures…
Benefit: Save your Time and Money
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 19
Disturbance analyzing
Event recorder
Up to 300 events with ms time stamp
Trend recorder up to 1h
Fault recorder for first analyzing
Disturbance recorder
32 samples per cycle
Up to 10s per record
Non volatile, 120s memory
Each status event, static or changes, is part of the record
Analyze your faults with low efforts
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 20
Product support statement HighPROTEC
Pricing for HighPROTEC-2 Release 3.0 will be unchanged to the
actual pricing
Available for sales 01st of October 2015
• Could be ordered now from today
The HighPROTEC devices Release 2.x (with blue front plate)
• Will get no functional update
• List price increase for Basic Products (not options) +20%
• Available for sales next two years
• Repair and support time minimum 7 years (1 of Oct.)
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 21
Any questions, remarks?
Thanks for your attention