MCA4-2 product presentation v01
Download
Report
Transcript MCA4-2 product presentation v01
HighPROTEC-2
MCA4-2 Directional Feeder Relay
Sales presentation
2015/08/10
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 1
MCA4 - Key Benefits
Cost savings for field service equipment and commissioning effort
Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring
Easy relay configuration achieves high service staff acceptance and
minimizes training expenses
Change tracking and plausibility check avoids parameter errors
Optimized overview by hidden protection modules in planning module
Text explanation for all parameter avoids misunderstanding
All in one protection functions by an optimized overview reduced risk of
changed customer requirements and to order a wrong devices type
Full Protection package for dir. OC, EC, Recloser, Power supervision, voltage, frequency…
Grid coupling and stabilization functions – Intelligent frequency load shedding for GRID stabilization, Q->U
protection, LVRT
With logic, up to 80 equations
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 2
MCA4 - Key Benefits
Production and maintenance flexibility
Flexible hardware covers a wide range of nominal values (Vn setting for DI, wide range power supply, wide
range voltage measuring, 1A/5A in one version)
Easy wiring at the rear side, pre wiring possible via terminal kit
All terminals are removable, including current measuring terminals
PC Tool Smart View for free
Page editor to create own pages and single lines
Easy connection between PC and Protection device via USB interface
Visualization of tripping curves graphically to get visual feedback of settings and protection concept
Look and feel over the complete HighPROTEC line -reduced training efforts
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 3
Product Ordering code - Easy to select
Basic description of Product
Directional feeder protection
with logic and control up to 6 switchgears 7 breakers
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 4
Meets Global Standards – for the global
market
Lloyds Register in preparation
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 5
Product Features - All in One
Protection functions, one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 6
Product Features - All in One
Protection functions, Control and Logic - one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 7
Product Features - All in One
Supervision functions - one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 8
Product Features - All in One
ANSI functional overview - one package
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 9
Product Features – Flexible Hardware
Rear side
X1
X2
X3
X4
X5 / X6
X100
X103
X104
Power supply and digital inputs
Relay outputs
CT measuring board
VT measuring board
MCA4A = not used
MCA4D = add. 6 binary outputs and 8 digital inputs
Ethernet Interface RJ45, (IEC, Modbus, Profibus, DNP3)
Communication Interface (IEC, Modbus, Profibus, DNP3)
IRIG/ Watchdog
Design advantages
Making it easier to apply worldwide
The flexible hardware minimized
commissioning, and ordering failures
Wide range power supply
24-270VDC / 48-230VAC
Nominal voltages for the digital inputs are per
software settable
VT measurement from 0V up to 800 V AC
CT measurement always with 1A and 5A
All terminal blocks are removable,
CT Connector with integrated short circuit
device
Housing based on aluminum extrusion parts
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 10
Market overview
Protection in medium voltage distribution and generator applications
Applications in different market areas:
Power plants
Infrastructure
Main distribution stations
Commercial buildings
Distribution substations
Industry like Heavy or Process industry
Chemical industry
Power generation – Protection of Generators
Grid Coupling of DER
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 11
Application Example MCA4
Example generation plant with
outgoing feeder to different
customers and grid coupling to the
upper MV distribution network
Usable for incoming, outgoing
feeders, bus coupling (synch check),
directional feeder applications and
at the grid connecting point
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 12
Application Control up to 6 Switchgears /
breakers, design your own page
Control function up to 6 switchgears
Extended interlocking management
Switchgear timing management
Switchgear status (display Single
Line)
PC Tool – Page editor
Page editor, easy to design a single
line or
measuring page
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 13
Application Logic – Highest Flexibility
Provides logic editor
Up to 80 equitation's
Select the gate type
Assignment of 4 logic input gates
Output gates with/ without timer
Latched, Set
Reset, Inverter
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 14
Commissioning and Maintenance
Fault simulation with the integrated V-I generator without additional wiring
Force and disarm relays, simulate temperatures…
Benefit: Save your Time and Money
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 15
Disturbance analyzing
Event recorder
Up to 300 events with ms time stamp
Trend recorder up to 1h
Fault recorder for first analyzing
Disturbance recorder
32 samples per cycle
Up to 10s per record
Non volatile, 120s memory
Each status event, static or changes, is part of the record
Analyze your faults with low efforts
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 16
Product support statement HighPROTEC
Pricing for HighPROTEC-2 Release 3.0 will be unchanged to the
actual pricing
Available for sales 01st of October 2015
• Could be ordered now from today
The HighPROTEC devices Release 2.x (with blue front plate)
• Will get no functional update
• List price increase for Basic Products (not options) +20%
• Available for sales next two years
• Repair and support time minimum 7 years (1 of Oct.)
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 17
Any questions, remarks?
Thanks for your attention
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC.
PAGE 18