HOW TO INSTALL UTH-HC4K THERMOSTAT
MODEL
SCOPE OF TEMP
SENSOR
FUNCTION / MOTION
UTH-190
0℃ ~ 80℃
NTC 5KΩ
SENSOR MODE (CENTIGRADE) / INTENSITY MODE
THANK YOU FOR YOUR PURCHASING OUR URIEL PRODUCT.
THIS MANUAL IS SUPPLIED FOR INFORMING HOW TO INSTALL THE PRODUCT ACCURATELY WHICH WILL PROTECT AGAINST THE DAMAGE OR TROUBLE CAUSED BY CARELESS INSTALLATION.
MUST READ THIS MANUAL CAREFULLY BEFORE INSTALLATION.
CAUTIONS
!
PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT WHETHER OR NOT THERE IS ANY
MISTAKE IN WIRING WORK OR ERROR ON THE VOLTAGE.
!
THIS PRODUCT HAS NO MAIN CIRCUIT BREAKER, PLEASE INSTALL IT ON THE OUTSIDE, IF NECESSARY.
!
THIS PRODUCT SHOULD BE USED AND MAINTAIN WITHIN THE CONDITIONS AND ENVIRONMENT SCOPE OF SPEC (VIBRATION/TEMP/HUMIDITY).
!
FOR PRECISE TEMP CONTROL, THE SENSOR SHOULD BE PLACED ON AN APPROPRIATE LOCATION AND PLACE.
※
THIS PRODUCT SHOULD NOT BE USED AT A PLACE WHERE IS FILLED WITH INFLAMMABLE, CORROSIVE OR EXPLOSIVE GAS OR VAPOR.
※
IF THE PRESENT TEMP IS EXCEEDING OVER THE SET TEMP, PLEASE SHUT OFF THE POWER SUPPLY AND CONTACT TO THE QUALIFIED ELECTRICIAN OR OUR HELP DESK.
!
FOR CLEANING THE SURFACE OF THIS PRODUCT, WISH IT LIGHTLY WITH WET AND SOFT CLOTH. DO NOT USE A DETERGENT OR THINNER.
BEFORE USE
- FOR PERFECT AND SAFE USE, PLEASE READ ALL INSTRUCTIONS IN THIS MANUAL.
- WHOLE OR PARTIAL REPRODUCTION OR COPY WITHOUT PERMISSION FORBIDDEN.
- THE CONTENTS OF MANUAL IS SUBJECT TO AN UNANNOUNCED CHANGE .
- IN CASE OF FINDING CONTENTS THAT IS AMBIGUOUS OR OMITTED, PLEASE CONTACT TO US BEFORE INSTALLATION.
- IN CASE OF NOT OBSERVING THIS MANUAL IN INSTALLATION OR WORKING, THE WARRANTY MAY NOT BE VALID.
SAFETY TIPS
SAFETY TIPS IS FOR USING THE PRODUCT APPROPRIATELY AND FOR PREVENTING AGAINST ANY BODILY INJURY OR PHYSICAL DAMAGES IN ADVANCE.
IT IS STRONGLY RECOMMENDED TO FOLLOW THE SAFETY TIPS
CHANGE OF FUNCTION AND MOTIONS
LAMP MARKS
HEAT ON : WHEN OUTPUT IS HIGH, IT IS MARKED “ON” (RED LAMP)
SET
: ONLY SETTING IT IS ON (GREEN LAMP)
POWER : FLICKER AT THE STATE THAT THE POWER OF CONTROLLER IS “ON” (RED LAMP)
BASIC MOTIONS
POWER IS ON/OF F WITH POWER KEY: DURING OFF, NO KEY WORKS.
UPON PUSHING ∨ OR ∧ BUTTON, THE SET LED IS ON AND THE SET VALUE IS DISPLAYED. NO CHANGE OF A KEY FOR 3SEC AFTER CHANGE OF SET TEMP., THE SET LED IS OFF AND
THE PRESENT TEMP. IS DISPLAYED.
FUNCTIONS
tn, THE START OF FUNCTION, IS DISPLAYED AFTER PUSHING ∨ AND ∧ KEY FOR 3 SEC SIMULTANEOUSLY .
IN THE DISPLAY OF tn, BY PUSHING ∧ KEY, MENU IS DISPLAYED IN THE ORDER OF En - in – St . IF SELECTING A MENU, PUSH ∨ AND ∧ KEY
SIMULTANEOUSLY.
Sn METHOD = THIS WORKS BY SENSOR; SET THE TARGET TEMP FOLLOWING TO <TABLE 1>.
FOR SETTING, AFTER SETTING THE TARGET TEMP, PUSH ∨ AND ∧ KEY SIMULTANEOUSLY. IN THE FINAL STEP, AU FLICKERS FOR 3 TIMES AND THE SET VALUE IS SAVED.
AFTER COMPLETING THE SETTING, SET THE TEMP WITH ∨ , ∧ KEY; IF NO CHANGE IN KEY, THE PRESENT TEMP IS DISPLAYED AFTER 3SEC. AND RUN.
Table 1
ROLE
DISPLAY
BASIC SET
SCOPE OF SET
MOTION DESCRIPTION
CLASS. OF FUNCTION
tn
SEN
SEN , TIMER , RESET
SEN(SENSOR MOTION MODE) , TIMER(TIME MOTION MODE) , RESET(INITIALIZATION)
MIN. TEMP SET
tL
O℃
0℃~ UNDER MAX TEMP
SET THE LOWEST TEMP WITHIN THE SCOPE OF TEMP
MAX. TEMP SET
tH
60℃
OVER MIN TEMP ~80℃
SET THE HIGHEST TEMP WITHIN THE SCOPE OF TEMP
TEMP DEVIATION SET
dF
2℃
0℃ ~5℃
ON/OFF MOTION IN THE DEVIATION BETWEEN SET AND PRESENT TEMP
OUTPUT DELAY TIME
dL
20SEC
01SEC ~ 60SEC
WHEN POWER IS ON, MOVE AS LATE AS THE DELAY TIME
OVERHEATING TEMP SET
oH
30℃
OVER MAX. TEMP~ 80SEC
DURING USING THE INDOOR SENSOR, IF THE SENSING TEMP OF Field SENSOR EXCEEDS
OVERHEATING SET TEMP, ERROR IS OCCURRED.
COMPENSATING TEMP SET
rS
00℃
-9℃ ~ 10℃
SCOPE FOR COMPENSATING THE DEVIATION OF REAL TEMP.
FUNCTION (TIMER MODE)
tl MODE = AS TIMER MODE, MEANS THE MODE WORKING BY SETTING “CYCLE” AND “STEP” . (SEE TABLE 2)
TIMER FUNCTION
BY PUSHING ∨ AND ∧ KEY FOR 3 SEC SIMULTANEOUSLY, THE INITIAL tn IS DISPLAYED. PUSH ∧ KEY ONE MORE, Sn IS DISPLAYED. AS Sn IS THE METHOD BY SENSOR, Sn
IS SAME TO THE PRESENT METHOD. IF PUSH ∧ KEY ONE MORE, tl IS DISPLAYED; AT THIS TIME BY PUSHING ∨ AND ∧ KEY SIMULTANEOUSLY , THE PRESENT CYCLE VALUE IS
DISPLAYED. SET THE CYCLE. WITH ∨ AND ∧ KEYS,. IF PUSHING ∨ AND ∧ KEY SIMULTANEOUSLY ONE MORE, AU FLICKERS AND THE CYCLE VALUE IS SAVED AND THE
PRESENT SET INTENSITY IS DISPLAYED.
HOW TO SET BY SERVICEMAN = PUSH ∨ AND ∧ KEY SIMULTANEOUSLY – tn DISPLAYS ON THE WINDOW – SELECT tl BY PUSHING FOR 2 TIMES – PUSH ∨ AND ∧ KEY
SIMULTANEOUSLY – DISPLAY THE CYCLE VALUE (CYCLE) – SELECT CYCLE (BASIC UNIT: 3MIN.) - SET CYCLE VALUE - PUSH ∨ AND ∧ KEY SIMULTANEOUSLY - AU FLICKERS –
SAVE COMPLETION
* HOW TO USE BY THE CONSUMER. = SELECT THE USE INTENSITY BY USING ∨ , ∧ KEYS (BASIC 1ST STEP)
Table 2
STEP
OUTPUT (0N)
OUTPUT (OFF)
1
15sec * S
45sec * S
2
20sec * S
40sec * S
3
25sec * S
35sec * S
4
30sec * S
30sec * S
5
35sec * S
25sec * S
6
40sec * S
20sec * S
7
45sec * S
15sec * S
8
50sec * S
10sec * S
9
55sec * S
5sec * S
10
60sec * S
0sec * S
REMARKS
※ S – selected cycle value
If 1min S=1
If 3min S=3
If 5min S=5
*
*
※ (If 20min s = 20 , value multiplying by 20)
※ (If 60min s = 60 , value multiplying by 60)
It is the length of ON and OFF.
TEMP RANGE AND INITIALIZATION FUNCTION
* THE BASIC CYCLE IS SETTING TO 3 MIN CYCLE (POSSIBLE TO SELECT 1 MIN TO 60 MIN FOR CYCLE)
* AFTER SELECTING CYCLE, PUSH - PUSH ∨ AND ∧ KEY SIMULTANEOUSLY, AND THE SET IS COMPLETED WITH AU FLICKERING.
* INTENSITY IS USED BY SELECTING AT THE TEMP WHAT CONSUMER WISHES.
* THE BASIC STEP IS SET THE 1ST STEP. (POSSIBLE TO SELECT 1 MIN TO 60 MIN FOR INTENSITY )
Initialization Set
1.
BY PUSHING ∨ AND ∧ KEY SIMULTANEOUSLY – tn DISPLAYS . THEN BY PUSHING ∧ KEY, THE ORDER OF Sn - tl - St IS PROCEEDING. BY PUSHING ∨ AND ∧
KEY SIMULTANEOUSLY WHILE Sn IS DISPLAYED, FF IS DISPLAYED. THEN PUSH ∧ KEY ONE MORE, “on” IS DISPLAYED AND BY PUSHING ∨ AND ∧ KEY
SIMULTANEOUSLY, SAU FLICKERS FOR 3 TIMES AND IT IS INITIALIZED.
2.
BY PUSHING POWER (ON/OFF) BUTTON FOR ABOUT 10 SEC, AU FLICKERS FOR 3 TIMES AND IT IS INITIALIZED.
TROUBLESHOOTING
ERROR MESSAGE
SNAPPING TEMP SENSING SENSOR
BASICALLY THE CONTROLLER IS ON/OFF ACCORDING TO THE INDOOR TEMP SENSING SENSOR. IN CASE INDOOR SENSING TEMP SENSOR IS SNAPPED,
IT IS CONTROLLED AND WORKS AT THE TEMP VALUE OF Field SENSOR AUTOMATICALLY. IF THERE IS NO Field SENSOR OR THE Field SENOR IS SNAPPED,
‘EO’ ERROR IS DISPLAYED AND THE OUTPUT IS OFF PROMPTLY.
(SUCH ERROR IS OCCURRED DUE TO THE FAILURE OF SENSOR SENSING UNIT; SHORT OF SENSOR EXTENSION LINE; ELECTRIC LEAKAGE FROM THE SPOT ATTACHING SENSOR . INSPECTION IS
NECESSARY AND IN CASE OF CLEAR, RETURN AUTOMATICALLY.)
SHORT CIRCUIT OF TEMP SENSING SENSOR
BASICALLY THE CONTROLLER IS ON/OF F ACCORDING TO THE INDOOR TEMP SENSING SENSOR..
IF THE INDOOR TEMP SENSING SENSOR IS SHORT, “ES” ERROR IS DISPLAYED AND POWER IS OFF. .
SHIRT CIRCUIT
OF INDOOR SENSOR
SHIRT CIRCUIT OF
OF Field SENSOR
IF Field TEMP SENSING SENSOR IS SHORT, “FS” ERROR IS DISPLAYED AND POWER IS OFF.
(SUCH ERROR IS OCCURRED DUE TO THE FAILURE OF SENSOR SENSING UNIT; SHORT OF SENSOR EXTENSION LINE; ELECTRIC LEAKAGE FROM THE SPOT ATTACHING SENSOR . INSPECTION IS
NECESSARY AND IN CASE OF CLEAR, RETURN AUTOMATICALLY.)
OVERHEATING ERROR
THIS OCCURS WHEN Field SENSOR SENSING TEMP IS HIGHER THAN THAT OF OVERHEATING SET TEMP. ..
“OH” IS DISPLAYED AND THE OUTPUT IS OFF PROMPTLY.
WITH MANUAL RETURN METHOD, POWER OFF-ON IN THE STATE THAT OVERHEATING ERROR IS CLEAR.
(CHECK THE STATE OF OVERHEATING SENSOR; CONTROLLER RELAY MOTION; SNAPPING OF Field TEMP SENSOR; OR SET TEMP VALUE)
SPEC.
CLASSI.
ITEM
Rated Input Voltage
100 V AC ~ 240 V AC (Universal voltage)
Output Voltage
100 V AC ~ 240 V AC (Universal voltage)
Driving Method
Electronic Type
Max Output
2 Kw/220 V
Power Unit
Load
Precision
Motion
Sensor
Function
(Capacity)
Others
SPECIFICATIONS
No. of Circuit
1 circuit
Max Capacity
12 A (Resistance load)
Temp Precision
± 1℃ ; change condition of 1℃ per 30 sec (Delay Option 20sec)
Power Input Display
Display ON , Power Lamp ON
Output Display
Heat Lamp: ON display
Range of Temp
Able to select within the range between 0 ℃ ~ 80 ℃
Output Delay(option)
01sec ~ 60sec
Kind
NTC : Negative Temperature Coefficient Epoxy molding
Precision %
1%
25 ℃ Rated Resistance
5000 ohm
Quantity
SENSOR 1 : for sensing indoor temp , SENSOR2 : for sensing Field temp (Option)
Safe
Device
Snapping/
Short of Sensor Line
Snapping of indoor temp sensing sensor: “EO” (Error Open) display and output cutoff
Short of indoor sensor: “ES” (Error Short), Short of Field: “FS” (Field Short) display and output cutoff (auto return)
Overheating Prevention
Sensor(Option)
Occurred in case the field sensor sensing temp is higher than the overheating temp, “OH” (Over Heat) display
and output cutoff
Resistance for Fuse
10 ohm (protecting the inside circuit of controller)
Outer Case
Anti-flammable
Weight
130g
Dimension (Mm)
90(W) * 90(H) * 45(D)
Temp
Used.
Air Temp
0 ℃ ~ 40 ℃
Air Moisture
Under 80 %