low harmonic

Download Report

Transcript low harmonic

MV
DRIVE SYSTEMS
Increase your efficiency with Schneider Electric
Confidential Property of Schneider Electric
Altivar 1200
THE PRODUCT
Altivar 1200
Motor FRIENDLY and LOW Harmonic Technology
Multi-level architecture
Compact & environment friendly
Innovative technology : Example of 6kV drive circuit
Altivar 1200 Multilevel architecture
> Output Voltage by Number of Cells
3,3kV 3 4,16kV
cells 4 cells
6,0kV 5 cells
Industry – IC&D – LoB Drive Systems – R. Holzer, R. Kapeller, Leo Fuchs 2015
Altivar 1200
Simple, Convenient, Reliable
Convenient
Easy Front access
design for Control &
Transformer
maintenance
Convenient
Control cabinet
optimized for an
Easy Customization
Convenient
Combined Control &
Transformer cabinet
Separated airflow
cooling
Complete
Well equipped as a standard : UPS,
LS, lightening, Security screw, door
locks…
Reliable
Modular inverter
stage cubicle for
fast maintenance
Reliable
Automatic
Contactless Cell
Bypass for a better
reliability
Altivar 1200
KEY FEATURES
Altivar1200 Key Features
Reduced Harmonic Technology
Input voltage (Green) and Current (Orange)
 Smooth to public grid
 30 pulse THDi < 3%
Waveforms
(line side)
 36 pulse THDi < 2%
 54 pulse THDi < 1%
 pF> 0.96 over the speed range
Altivar 1200 Key Features
Reduced Harmonic Technology
●LOW HARMONIC or negligible harmonics
● All standards like IEEE 519.1992 inherently fulfilled
●Save installation costs because no additional filters
needed (CAPEX)
●Save costs of losses in your transformers and grid due to
low harmonics (OPEX)
Altivar 1200 Key Features
Motor FRIENDLY
●Great Waveform
Voltage (Green) and Current (Orange) on motor side
ATV1200 Key Features
Motor FRIENDLY
●No dU/dt peaks stressing motor insulation
●No output current harmonics are increasing rotor losses
● THDi < 2%
ATV1200 Key Features
Motor FRIENDLY
● Run EXISTING old motor
● Run all brands of motors
●Long cable distances allowed
● Up to 1000m and more
●Save money with energy saving projects at your old
motor
● Save money with standard motor
Altivar 1200 Key Features
Motor FRIENDLY
● Perfect waveform and input
transformer avoids
bearing currents
● Transformer and multilevel
is the only
architecture to cut
common mode
voltage effects
Altivar 1200
PERFECT for OLD Motors
..at Pumps
& Fans
(ROI < 2 Years)
Altivar 1200
Premium & Standard
● Different Transformer Execution means:
● Providing cost
effective execution with Standard
Transformer selection
Altivar 1200
CONTACTLESS SYMETRICAL CELL BYPASS
●Solid State Devices do work under
all environmental conditions
● E.g. a contact will not be reliable in a cement
factory if 2 years not operating
Altivar 1200
Easy to operate
Altivar 1200
KEY Features & Options
● All Field Busses to =SE= PLC
● No PC needed
● Key Interlock
● UPS inside as standard
● Internal Fan supply
saves aux. supply
(CAPEX)
● Synchronous Transfer
Altivar 1200
APPLICATIONS
MV Drive Offer
Schneider Electric as Key Player
10250
1409
3130
1470
installed Units
Key segments : O&G, Mining, Power Gen. Metal, Water
Power
Oil&Gas
Water
Installed based in more than 25 countries
Metal
Mining
Other
1190
2240
810
12500 MW
installed power
Energy Managment expertise
Application Process knowledge
Industry – IC&D – LoB Drive Systems – R. Holzer, R. Kapeller, Leo Fuchs 2015
12050kW 11kV Gas Compressor Starters
>
Place: Badra Oilfield, IRAQ
>
Customer: M.A.N Turbo & Diesel
>
Application: Centrifugal Compressor
>
Customer requirement:
Synchronous Transfer
Multiple ETO requirements according
O&G standards
>
Product: ATV1200 A14900 1111 A4S
>
Contact: Schneider Electric Germany
Industry – IC&D – LoB Drive Systems – R. Holzer, R. Kapeller, Leo Fuchs 2015
1500kW 3300V District Heating Line Pumps
>
Place: ROTERDAM
>
Customer: AVR
>
Application: Line Pumps
>
Customer requirement:
Reliability
>
Product: ATV1200 A1830 3333 A4S
>
Contact: Schneider Electric
Netherlands
Industry – IC&D – LoB Drive Systems – R. Holzer, R. Kapeller, Leo Fuchs 2015
1750kW, 780kW 6,6kV Loading Pumps
>
Place: Pengerang, Malaysia
>
Customer: VOPAK, Dialog, Petronas
>
Application: Loading / Unloading
Pumps
>
Customer requirement:
6,6kV, low harmonic
>
Product: ATV1200 A2020 6666 A3S
>
Contact: Schneider Electric Kuala
Lumpur
Industry – IC&D – LoB Drive Systems – R. Holzer, R. Kapeller, Leo Fuchs 2015
Overland conveyor
>
Place: Australia
>
Customer: Rio Tinto Mesaa, WA
>
Application: Conveyor twin drive
>
Customer requirement: Multi drive with 1 x “synchronizer”
Master and torque controlled slaves
>
Product: 3,3kV - 2 x 800kW - 1 x 400kW
>
Contact: Schneider Electric Beijing
Industry – IC&D – LoB Drive Systems – R. Holzer, R. Kapeller, Leo Fuchs 2015