Fire alarm control panel

Download Report

Transcript Fire alarm control panel

Explanation of Various Functions of the Machine/
Automatic Test Function:
The machine can self perfrom automatic scanning test for an internal
return motion or circuit break inside the switchboard, to facilitate the
maintenance/repair test motion to turn from complication into simplicity
, and upgrade work performance and reliance of the mainframe.
Storage Function:
The return detection shall only go through confirmation of a fixed period
of time prior to engagemement of alarm motion, to reduce the disturbance
and error report situation of general circuits, and upgrade the reliability of
the mainframe.
Reserved Power Protection Device:
Under the condition of power suspension, the reserved power with a power
release till below DC-18V, power discharge will be automatically stopped,
to extend the battery service life.
Quality Control:
The parts used for the operation panel of the Machine and internal base borad are all through CN Squality
recognition;
規格 / the mainframe before ex-plant shall go through a strict test to ensure service function to be
normal and without an error.
Humanistic Design:
The internal base boards are all in modular design; the external line output/input is separated by a terminal
board; and due protection measures are provided to the input terminal. If an insitu wrong connection of
external power into a return board, it is only required to replace the return board of the said return, without
a need of dismantling external distributing circuits, to facilitate the maintenance/inspection performance to
be upgraded considerably.
Outlook Design:
High class feat resistant plastic material is applied for the return display panel of the Machine. The outlook
is in streamline, simple and graceful. It is coped up with return indication plate, building unit attribte, floor
level, with easily preceived return attribute.
Other Applications:
The furnction and the paging mainframe with emergency telephone mainfarme manufactured by the
Company are complied into one entity with 3 machines, to attain a conformity of case frame and outlook.
Characteristics of the Machine /
Characteristics
Advantages
Advantages in Use
Automatic test function
Automatic scanning test
of internal return
Uperade work performance,time
saving,labor saving
Storage function
Upgrade reliance, reduce
wrong report ratio
Reserved Power
protection
Upgrade battery life
Qualtity control
Upgrade reliability of mainframe
Reduce maintence cost,increase
revenue
Humanistic design
Convenient for fabrication
Upgrade work performance,time
saving
Outlook design
Easy to understand the motion of the
mainframe & return panel outlook is
beautiful
Simple circuit layout/
Apply 2 units of super large type circuit
slot, to ensure easy circuit layout
Avoid nonsense work hour
consumption
Save maintenance/repair cost,battery
consumption
Easy to facilitate a user to operate
Save circuit trimming time,labor
saving
External Dimension
Case
type
lron
rolling
door
Circuit
No.
1L
H(mm)
Ground falling
type
Wall hanging type
Other
Size
5L
10L
15L
20L
25L
30L
35L
40L
45L
50L
55L
60L
65L
80L
85L
-100L
100L
150L
155L
170L
250
400
580
580
700
760
840
1195
1350
1800
2000
W(mm)
210
300
300
480
480
480
480
480
580
580
580
D(mm)
90
120
120
180
180
180
200
200
200
360
360
Can
alsc
be
Ordered
Specification List
ltem
Content of specification
Model
HC-AL
Power(AC)
AC110V
Reserved power
Charging
Voltage/Current
50/60Hz
DC24V
DC26V
450mAbelow
Circuit Voltage/Current
DC24V short circuit voltage below 5V 32mA
Return external circuit
resistance
Black& forth below50Ω
Detector installation
Differential type,fixed-temperature type smoke detector(DC24V 80uA) a
smoke detector can be accessed for no more than 18 units each L
Terminal resiatance
10KΩ
Quantity of indication
1.3 times of the panel return
Regional alarm quantity
1.3 times of the panel return
Material of machine
frame
1.6m/m-2.0m/mstandard material
Main stereo
Double noise above BUZZER
92db
Connection joint for
transfer report
No voltage connector capacity AC150V7A
Controller of an iron
rolling door
generally applicable to 100V~220V