Electrical safety of LHC quench heater circuits in case of

Download Report

Transcript Electrical safety of LHC quench heater circuits in case of

Electrical safety of LHC quench heater circuits in case of
faulty heaters by
 Motivation
– So far quench heater power supplies have to be switched off prior to
work on the corresponding DFB for reasons of electrical safety
• No problem for insertion region magnets (up to 12 power supplies
per DFB)
• Significant amount of work for the main circuits (up to 718 power
supplies per arc)
 Risk of an electrical shock hazard caused by the quench heaters is
extremely unlikely under normal operating conditions
AT-MEI-PE, RD, MPP 16-JAN-2008
– People follow the rules …
– Installations are conform (i.e. quench heaters are isolated from the cold
mass and the coils)
 Electrical shock hazard may be possible in case of
– Vandalism and other severe professional faults …
– Earth fault of quench heater circuit & (spurious) trigger of quench
detection system  to be checked
1
Experimental setup
 Proposal by Hugues: experimental verification of “worst case scenario”
– Measure voltage developed by fault current in case of discharge into a heater
exhibiting an earth fault
AT-MEI-PE, RD, MPP 16-JAN-2008
– Determine the possible risk for a human connected in parallel (e.g. leaning
across a DFB)
2
Results & conclusions
 As expected fuse blows and protects the equipment
 Maximum observed voltage: U_max = 22 V, t < 0.1 ms
 Tested configuration represents no risk for electrical shock hazard
– is it really the worst configuration?
 QPS prefers nevertheless that the current leads will be connected prior to
charging the quench heater power supplies
AT-MEI-PE, RD, MPP 16-JAN-2008
– ELQA has to be finished as well (possible source of spurious triggers)
 All current leads must be shorted and properly earthed before work on the
DFB can start (in case quench heater power supplies are charged)
– Proper earth connection requires low resistance and inductance
 For all circuits other than RB, RQD and RQF the quench heater power
supplies will be switched off in case work on the DFB is necessary