Transcript ComfortG2

Comfort II
Whats New (updated Jan 2008)
Two-Piece Design
• Consists of CPU Board and DSP Board,
joined by a 28 way connector
• CPU Board has Inputs, Outputs, Siren,
Strobe, KA/KB, 12V etc for Alarm functions
• DSP Board has Tel In, Tel Out, Voice, Mic,
power supply for Voice and Dialing
functions
Slave
• New Generation Slave will be the CPU
Board with Slave firmware
• Power Supply board will replace the DSP
board connected to the Slave
Flash Upgrades
• Flash Firmware upgrade is available
as Plug-in Module (MPU01)
• Comfort II with Flash MPU plug-in
(see picture) can be upgraded by
firmware download via Comfigurator
2.2.x. This requires new UCM05
• In 2008, Comfort II PCB will come
with built-in Flash firmware and will
not require MPU01
UCM05
• New UCM05 is able to download new
firmware upgrades to Comfort II with builtin Flash or Flash MPU. Requires
Comfigurator 2.2.x
• Programming Cable connects UCM05 with
Comfort II, Slave II or UCM05/EIB/CBUS
to be upgraded
• IR Learning is standard feature
Local Expansion Modules
• LEM01-M2 or LEM02-M2 or LEM03-M2
will plug on top of CPU or Slave Board
• Output module will be plugged into LEM
and can be removed
Battery Protection
• Battery protection function is built in.
BPM01 Module not required.
• Prevents over-discharge of battery
• Current limits charging current to a low
battery
Piggyback Modules
• Ringer Module RGR04 can be plugged in
• LEM can be plugged in
• Output Module can be plugged in. This
allows damaged Outputs to be replaced
without any downtime
• Firmware upgrades can be plugged in
• Saves space in the enclosure
Isolation
• Comfort circuitry is isolated from earth.
Plastic standoffs for mounting PCB
• Provides better protection from lighting
induced surges.
• All Inputs and Outputs have been tested to
4kV surge.
• Improved Telephone line protection
Testing/Approvals
• EMC compatibility for US and European
standards
• Safety testing for CE Mark
• PSTN standards compliance to US,
European and Australian standards
• Tested to extended surge voltages (4 KV)
compared to European standards
Full Duplex Intercom
• Full Duplex Intercom between Tel and
KP/DP and between KP and DP
• New KP04 versions needed with better
acoustic isolation
• KP03 and DP03 replaces KP01/02 and
DP01
• DP and KP have separate Mic/Voice
connections
Various Improvements
• Better Busy Tone detection during
recording, voice menu, Intercom
• Automatic Gain Control (AGC) during
recording
Vocabulary Tool
• VoiceProc software allows customisation
of wordlists for specific applications and
development of vocabularies in other
languages
• VoicePlay allows sentences to be heard in
compressed and original form
System Voltage
• CPU and DSP circuitry operates at 3V
instead of 5V.
• This means analog input voltage is 0 to 3V
Other New Features
• Conditional Branch Instructions will
improve if/Then code generation
• 32 Time Programs
• 16 Reminder Messages
• Say Word Action
• 64 User Timers
Compatibility
• All current external modules on RS485
bus will remain compatible (Slaves, RIOS,
Keypads, Door Stations, UCMs)
• KP01, KP02, KP04, DP01 will remain
compatible but with poor performance for
full duplex intercom. Upgrade to KP03,
KP04/X, DP03 is recommended
Comfort I v Comfort II
• Comfort I Ultra
–
–
–
–
8 reminders
16 time programs
16 User timers
One-way intercom ½
duplex between KP and DP
– File System 24
– Firmware upgrade via
change of U1 IC
• Comfort II Ultra
–
–
–
–
16 reminders
32 time programs
64 User timers
Two-way intercom full
duplex between KP and DP
– File System 34
– Firmware upgrade via
download to MPU01 or
Flash firmware