10c EMT212 REGULATORS-TERMINOLOGY
Download
Report
Transcript 10c EMT212 REGULATORS-TERMINOLOGY
EMT 212
ANALOG ELECTRONICS
Professor Robert T Kennedy
Prof. R T Kennedy
USER
DESIGNER
Knowledge of Specifications
Translate Specification
Ability to Specify
Decisions:
How to Achieve it
Topology:
(Linear/Switching/Resonant/0ther)
Discontinuous/Continuous Current
Control Strategy:
(Vo ltage /Current Mode)
Evaluate & Test
Design Iteration
USE IT
Prof. R T Kennedy
OUTPUT VOLTAGE RANGE
Vout max
range
Vout nom
Vout min
maximum-minimum band about nominal value
OUTPUT VOLTAGE ERROR BAND
Prof. R T Kennedy
OUTPUT VOLTAGE ACCURACY
Vo Vo(nom)
Vo(acc)
Vo(nom)
maximum deviation
operational output voltage – specified nominal
Vo measured output voltage
nominal input voltage and rated load current
OUTPUT VOLTAGE TOLERANCE
Prof. R T Kennedy
LINE REGULATION
LINE REGULATION
Vo(high in) Vo(low in)
Vo(nom)
CHANGE IN OUTPUT VOLTAGE
due to
SPECIFIED CHANGE IN INPUT VOLTAGE
at
SPECIFIED LOAD CURRENT and TEMPERATURE
SOURCE or VOLTAGE EFFECT
Prof. R T Kennedy
LOAD REGULATION
LOAD REGULATION
Vo(high load ) Vo(low load )
Vo( full load )
CHANGE IN OUTPUT VOLTAGE
due to
SPECIFIED CHANGE IN LOAD CURRENT
at
SPECIFIED INPUT VOLTAGE and TEMPERATURE
LOAD EFFECT
Prof. R T Kennedy
PARD
PERIODIC and RANDOM DEVIATION
LINE RIPPLE
VOUT
SWITCHING RIPPLE
LINE & SWITCHING RIPPLE
PERIODIC rms or peak-peak
AC EFFECTS
SWITCHING TRANSIENTS
RANDOM
peak-peak
Prof. R T Kennedy
DROPOUT VOLTAGE
minimum input-to-output voltage differential
for regulation by the regulator.
VOUT = 5 V
VDO
= 0.3 V
VINmin = 5.3 V
Prof. R T Kennedy
GROUND CURRENT
the portion of regulator supply current
that flows to ground instead of to load
Prof. R T Kennedy
QUIESCENT CURRENT
current used by the regulator
for housekeeping
Prof. R T Kennedy
PROTECTION
OVERTEMPERATURE SHUTDOWN
disables the output when the regulator
temperature rises above a safe threshold
OVERVOLTAGE SHUTDOWN
disables the output when the input
voltage rises above a certain threshold
Prof. R T Kennedy