Hydra Review
Download
Report
Transcript Hydra Review
Introducing the microK
Isothermal Technology Ltd
microK Slide:1
What is the microK?
A New Instrument providing
performance better than 1mK
Manufactured by Isotech
Designed Exclusively for Isotech
Not a badged instrument
microK Slide:2
Why is it exciting?
A great deal, it is the most accurate instrument
in its class, the only instrument to work at this
precision with platinum resistance
thermometers, thermistors and thermocouples.
The core measurement technology was
developed in conjunction with the National
Physical Laboratory
NPL and microK has the sole license for the use
of this technology for temperature
measurement.
microK Slide:3
The A to D
Uses specially designed analogue to digital converter
used in conjunction with a digital signal processor
(DSP)
Uses a unique adaptation of existing advanced
sigma-delta ADC techniques to achieve linearity
better than 0.4 ppm.
A further major benefit of this ADC technique is its
low noise performance,
reduced by a factor of 32 over conventional sigmadelta ADC circuits.
microK Slide:4
Accuracy
The microK achieves 0.4ppm over the
whole range
For SPRTs equivalent to 0.4mK
For Voltage the specification is 250nV
at 20mV
Equivalent to 0.01°C for a Gold Platinum
thermocouple at 1000 °C
microK Slide:5
Accuracy
Resolution
Resistance: 0.01ppm of range
Voltage: 10nV on 125mV Range
Stability Voltage
3 ppm / year
microK Slide:6
Resistance AND Voltage
microK supports
SPRTs and IPRTs
Thermistors
Thermocouples
Only instrument in its
class to do this
A DVM with comparable
performance has a similar
cost to the microK alone
microK Slide:7
Zero Drift for Resistance
The microK uses a “substitution
technique” in which the Device-Under-Test
and the Reference are successively
switched
This means that the stability of resistance ratio
measurements is immeasurably small
microK Slide:8
Three Channel
Three Input Channels
Best Practise Ready
Allows two standards and a device under test to
be connected simultaneously
microK Slide:9
Easy to Use
Operated by
large touch
screen display
Intuitive
Can add
keyboard and
mouse
microK Slide:10
Easy to Use
Includes Graphing Facility
Auto or Manual Scales
Intuitive
microK Slide:11
Easy to Use
Log Data to Internal Memory
Or USB Pen Drive
microK Slide:12
Solid State - Reliable
All Solid Sate
Reliable
No
No
No
No
potentiometers
Dials
Knobs
Relays
microK Slide:13
microK
A new standard for secondary calibration laboratories
microK Slide:14
Accuracy - SPRT
Better than 1mK Over Whole Range
Channels
Three
Probes Supported
SPRTs, PRTs, Thermistors and
Thermocouples
Solid State Design
All solid state NO relays or dials
Stability
0ppm / per year
Measurement Time
1 Second
PC Interface
RS232 and USB
Units
Ratio, V, °C, °F and K
microK – Further Information
Http://www.isotech.co.uk/
microk
Data Sheet
Technical Articles
Article From Cal Lab
Magazine
Latest News
microK Slide:15
microK
A new standard for secondary calibration laboratories
microK Slide:16