PremiSys - IDenticard
Download
Report
Transcript PremiSys - IDenticard
PremiSys™
Product Overview
IDenticard – Company Profile
Established in 1971 and quickly emerged as the
leader in ID card manufacturing
Headquartered in Lancaster, Pennsylvania
Brought to market first access control software
product in 1982
Introduced the first Windows-based access
control system in 1991
Developed first digital imaging software
product , IVIS Plus, in 1994
Established initial dealer network in late ’80’s
Customer base: approximately 15,000 –
consisting of both end users and dealers
Acquired by Brady Corporation in February,
2006
About Brady Corporation
Founded in 1914 and is headquartered in
Milwaukee, WI
Operations in 26 countries with over 9000
employees
Over $1.5 Billion in Sales Revenue for fiscal ’11
Brady’s business – Identify & protect premises,
products & people
Major product lines provided include facility
identification and security, safety &
complementary products, wire identification
products & people identification.
Products provided to the OEM market include
high performance identification products for
printed circuit boards and precision die-cut
components for mobile telecommunications
devices and hard disk drives
Additional Brady Security Group
Companies
- Visitor Management Products
– Self Expiring Badges
– Badging Accessories
Tiscor – Automated documentation of Life Safety
equipment inspections
PremiSys™ Access Control
and PremiSys ID™
Operating Systems Information
•
•
•
•
•
•
•
•
Windows 7
Windows 2008 Server
Windows 2003 Server
Windows XP
Windows 2000
Virtual Environment supported
Uses Software license key vs hardware key
Installs with SQL Express can be upsized to
full SQL
Software Architecture
• Shared “IDenticard Windows Service”
• Shared Application
• Tiered product levels provide software
options
• Available with or without PremiSys ID
Badging client
• Client licensing based on concurrent
users
Licensing
•
•
A PremiSysID client is required for card printing
A PremiSys client can perform all other functions allowed by
the feature set of both PremiSys and PremiSys ID
Badging Station
Guard Station
PremiSys Licensing Model
Three levels of access control software
PremiSys LT
• 8 reader maximum, 1 client, no badging
• Simple to upgrade software license to take product to next
level
• Same feature set of PremiSys
PremiSys
•
•
•
•
3 client maximum
40 reader maximum
Modified feature set
Simple to upgrade software license to take product to next
level
PremiSys Pro
• No imposed restriction on clients
• No imposed restriction on readers
Supported Reader Technologies
•
•
•
•
•
•
•
Proximity
Smart Card
PIV/CAC/TWIC/FRAC
Biometric
Magnetic Stripe
Barcode
Vehicle Readers
Other system features
•
Mobile App
o
•
Manage cardholders, print ID cards, lock, unlock & lock out doors,
acknowledge alarms, run quick reports
3rd party integrations:
–
–
Schlage Wireless Reader Interface
Video Integration
o
o
–
Visitor Management Integration
•
•
–
Stopware
EasyLobby
Integration with MorphoTrack
•
•
•
•
•
Exacq
American Dynamics
FIPS 201 compliant
Approved product list http://fips201ep.cio.gov/apl.php
Email notification
LDAP Connection for user log on
Dynamic mapping for easier system monitoring
Other features
• API for development of 3rd party
interfaces
• Scheduler
o
o
o
o
o
Special Door events
Report
Backups
Archives
Imports
Hardware Overview
There are two types of Hardware
Controllers- Microprocessor board with on board
ethernet connectivity, memory retains all cardholder
access information and makes all decisions for
devices connected to it
SIO Boards- Serial interface boards connect to
controllers via 2 wire 485 communications providing
connections for readers, inputs and outputs
9000 vs. PremiSys Hardware Architecture
System drawing showing boards and connections
Lan/Wan
System can be accessed on a
client PC or through the
mobile app on an iPhone or
Android device
PREM-CTLR1POE
1 Door PoE
controller can
communicate with
up to 8
downstream SI/Os
or 16 1 Door PoE
boards.
PREM-CTLR2RDR
2-wire RS485 connects up to 32
downstream devices to the controller
PREM-BRD2RDR
PREM-BRDIN
PREM-BRDOUT
PREM-BRD1RDR
Support up to
64 doors using
2-door SI/O
boards
PREM-BRD1POE
Additional input and output boards
can be used to connect devices
like glass break sensors or used to
control elevator cars
1 Door boards
are also
available for
placement
near a door
Hardware Architecture
• Controllers
– 1 Door POE Controller
– IP Controller with 2 Readers
– IP Controller
• SI/O Boards
–
–
–
–
–
2 Reader
1 Reader
1 Reader POE
16 Input
16 Output
• Multiplexer Boards
– MUX 8
One Door POE Controller
•
•
•
•
•
Communications with the host PC are via Category 5
Ethernet cable, through a network.
The controller can communicate via RS-485 to 8
downstream I/O boards
A total of 17 doors are supported (1 built in and 16
downstream)
Includes 2 reader ports (controls 1 door)
• The 2nd reader port is used:
•
•
•
•
To communicate with downstream I/O boards
As an ‘Out’ reader
Supports over 100,000 active cardholders
Can be utilized in upgrading existing IDentiPASS
systems supporting 16 downstream readers
1 Door PoE Controller General Configuration
Lan/Wan
PREM-BRD1POE
Will communicate to a total of 16
downstream doors using SI/O
boards connected via two-wire
RS-485 or ethernet
Dry contact for lock
Door Position Input
PREM-CTLR1POE
RTE
PREM-BRD2RDR
Input Voltage: PoE Power Input 12.95W compliant to IEEE 802.3af or 12 VDC
± 10%, 900 mA maximum Note: For UL installations, power for PoE devices
must be provided by a UL 294 listed source (12 VDC), not via PoE.
2 – Reader ports (1 Door)
Ethernet to Host
2 - SPDT, Form C relays
2 - Configurable input points
1 - Unsupervised, dedicated input points for enclosure tamper
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
2 Reader Controller PREM-CTLR2RDR
•
•
•
•
•
•
The Two-Reader Controller includes the following
components and features:
Onboard Ethernet
Two reader ports
16 MB non-volatile flash memory for card and system information
and 1 MB SRAM for transactions and new card information
Supports over 200,000 active cardholders and 64 card readers
A 3-volt lithium coin cell that provides RAM and clock backup
2 Reader Controller General Configuration
Lan/Wan
Two-wire
RS-485 to
SI/O boards
Dry contact for lock
Door Position Input
RTE
PREM-CTLR2RDR
Input Voltage: 12–24VDC±10%,500mA maximum(reader current not included)
Card Reader Power: 12 VDC (10.8-13.2 VDC) ± 10%,nominal or unregulated,
current limited to 150mA for each reader OR 12 to 24Vdc±10%(pass-through
voltage) current limited to 125mA for each reader
2 – Reader ports
Ethernet or RS-232 to Host
4 - SPDT, Form C relays
8 - Input configurable input points
2 - Unsupervised, dedicated input points for enclosure tamper and power loss
Supports up to 32 downstream SI/O boards
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
PREM-BRD2RDR
IP Controller (PREM-CTLRIP)
•
•
•
•
•
•
The IP Controller includes the following components and
features:
Onboard Ethernet
An alternate port for RS-232,RS-485 or a second Ethernet
connection via a Network Card, allowing redundancy to the
host in the event that the primary host-communications link is
lost
16 MB non-volatile flash memory for card and system
information and 1 MB SRAM for transactions and new card
information
Supports over 200,000 active cardholders and 64 card readers
3-volt lithium coin cell that provides RAM and clock backup
IP Controller General Configuration
Lan/Wan
Two-wire RS-485 to SI/O boards
Supports 32
downstream SI/O
boards per channel
Two-wire RS-485 to SI/O boards
PREM-BRD2RDR
PREM-BRD2RDR
PREM-CTLRIP
Supports 32
downstream SI/O
boards per channel
Input Voltage: 12 – 24VDC±10%,300mAmaximum, 12VDC@240mA(325mAwithNetworkCard)nominal,
24VDC@135mA(175mAwithNetworkCard)nominal
Primary - Ethernet to Host
Port 1 - (alternate) RS-232 or RS-485 to Host or Ethernet to Host via separate Network Card
Ports 2 & 3 – Twisted pairs, 22 AWG (0.325mm2),with shield; Maximum cable length: 4000 feet (1219meters) of
wire, total copper, including drops. Used for communicating to downstream SIO boards
2 - Unsupervised, dedicated input points for enclosure tamper and power loss
Supports up to 64 downstream SI/O boards
Supports maximum of 64 doors
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
2 Reader Board (PREM-BRD2RDR)
•
•
•
Uses two-wire RS-485 to communicate upstream
The Two-Reader Board can be housed in a sturdy and
optionally lockable enclosure with its controller and/or
other components
The Two-Reader Board includes the following
components:
o Six relays configurable for normally open or normally closed
operation
o Eight general-purpose input points that can be supervised or
not to serve as door-input points, request-to-exit points, etc.
o Two dedicated input points for monitoring power loss to the
board and enclosure tampering
o A DIP switch for addressing the board and setting other
parameters
o LEDs to indicate board and relay status
2 Reader Board General Configuration
Lan/Wan
PREM-CTLR2RDR
Two-wire RS-485
to controller
PREM-BRD2RDR
Input Voltage - 12 VDC ± 10%,550mA peak (plus reader
current), 450mA (plus Reader current) nominal
6 - SPDT, Form C relays
8 - Input configurable input points
2 - Unsupervised, dedicated input points for enclosure tamper
and power loss
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
1 Reader Board (PREM-BRD1RDR)
•
•
•
Uses two-wire RS-485 to communicate upstream
The One-Reader Board can be housed in a sturdy and
optionally lockable enclosure with its controller and/or other
components
The One-Reader Board includes the following components:
o Two relays configurable for normally open or normally closed
operation
o Two general-purpose input points that can be supervised or not
to serve as door-input points, request-to-exit points, etc.
o Dedicated input point for monitoring enclosure tampering
o Jumpers for setting EOL resistance, addressing the board and
setting other parameters
o LEDs to indicate board and relay status
One Door Reader Board General
Configuration
Lan/Wan
PREM-CTLR2RDR
Two-wire RS-485
to controller
PREM-BRD1RDR
Input Voltage - 12 VDC ± 10%,150mA peak (plus reader current), 110mA
(plus reader current) nominal
Card Reader Power - 12 VDC ± 10%(input voltage passed through)
2 Form C, SPDT Relays - K1: 5 A at 28 VDC, K2: 1 A at 28 VDC
2 input points - end-of-line (EOL) resistors, 1K/2K ohm1%, ¼ watt standard
1 - Unsupervised, dedicated input points for enclosure tamper
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
One Door PoE Board (PREM-BRD1POE)
•
•
•
Communications with controllers are via Category 5 Ethernet
cable over a network.
The PoE One-Door Reader Board can be mounted in a threegang junction box with an optional magnetic tamper switch.
The PoE One-Door Reader Board itself includes the following
components:
o
o
o
o
o
An embedded Ethernet port for communication and power to the
board, readers and door (depending on power needs)
Jumper for setting either power-over-Ethernet or a separate 12-VDC
power supply to the board
Two relays configurable for normally open or normally closed
operation
Four general-purpose input points that can be supervised or not to
serve as a door-input point, request-to-exit point, enclosure tamper
point, etc.
LEDs to indicate board and relay status.
One Door PoE Board General
Configuration
Lan/Wan
PREM-CTLR1POE
PREM-BRD1POE
Up to 16 PoE boards can be
connected to a single PoE
controller via an Ethernet
connection
Input Voltage - 12 VDC ± 10%,150mA peak (plus reader current), 110mA
(plus reader current) nominal
Card Reader Power - 12 VDC ± 10%(input voltage passed through)
2 Form C, SPDT Relays - K1: 5 A at 28 VDC, K2: 1 A at 28 VDC
2 input points - end-of-line (EOL) resistors, 1K/2K ohm1%, ¼ watt standard
1 - Unsupervised, dedicated input points for enclosure tamper
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
16 Input Board (PREM-BRDIN)
•
•
•
Communication with controllers or a MUX is two-wire RS485.
The Input Board can be housed in a sturdy and optionally
lockable enclosure with its controller and/or other
components.
The Input Board itself includes the following components:
o Sixteen general-purpose input points that can be used with
supervision and can fulfill any input-point function: door-input
points, request-to-exit points, motion-sensor inputs, etc.
o Two dedicated input points for monitoring power loss to the
board and enclosure tampering
o Two relays configurable for normally open or normally closed
operation
o A DIP switch for addressing the board and setting other
parameters
o LEDs to indicate board and input status
16 Input Board General Configuration
Lan/Wan
PREM-CTLR2RDR
16 Inputs
PREM-BRDIN
Two-wire RS-485
to controller
2 Outputs
Input Voltage - 12 VDC ± 10%,350mA peak,300mA nominal
2 - SPDT, Form C relays, 5 A at 28 VDC, noninductive load
16 - Sixteen assignable input points, end-of-line (EOL)
resistors,1K/2K ohm1% watt standard
2 - Unsupervised, dedicated input points for enclosure tamper
and power loss
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
16 Output Board (PREM-BRDOUT)
•
•
•
Communications with the controllers or MUXes are two-wire
RS-485.
The Output Board can be housed in a sturdy and optionally
lockable enclosure with the controller and/or other
components.
The Output Board itself includes the following components:
o Sixteen Form C, SPDT output relays, configurable for normally
open or normally closed operation.
o Two dedicated input points for monitoring power loss to the
board and enclosure tampering
o A DIP switch for addressing the board and setting other
parameters
o LEDs to indicate board and relay status
16 Output Board General Configuration
Lan/Wan
PREM-CTLR2RDR
16 Outputs
PREM-BRDOUT
Two-wire RS-485
to controller
Input Voltage - 12 VDC ± 10%,1100mA peak,850mA nominal
16 – SPDT, Form C relays, 5 A at 28 VDC, noninductive load
2 - Unsupervised, dedicated input points for enclosure tamper
and power loss
*Items not drawn to scale. Refer to the PremiSys Hardware Installation manual for actual terminations.
Multiplex Board (PREM-BRD8MUX)
MUX-8
• The MUX-8 is an eight port RS-485 multiplexer that
takes a RS-485 or RS-232 input and create eight 2wire RS-485 communication channels.
• Common uses are for:
–
–
–
–
star topology wiring schemes
home-run wiring
when wiring distances exceed the 4000 ft. limit of the RS-485
standard
Isolation of 9000 and RI/O panels to independent RS485
channels
Controller – MUX – SI/O’s
Lan/Wan
PREM-CTLR2RDR
PREM-BRD8MUX
Use the MUX for up to
8 downstream 2-wire
RS485 channels of
communication.
Server – MUX - Controller
Use the MUX for up to
8 downstream 2-wire
RS485 channels of
communication.
PREM-BRD8MUX
PREM-CTLRIP
PREM-CTLRIP
Enclosures (PREM-ENCLG) (PREM-ENCSM)
Large Enclosure (PREM-ENCLG)
•
•
•
•
•
W18” x H21 ¼” x D3.5”
Holds 8 (any combination) of the following boards
o IP Controller
o 2 Reader Controller
o 2 Reader Board
o 16 Input Board
o 16 Output Board
Using adapter plate, two 1 Reader Boards will take space of 1 of
the other boards
Can use adapter plate to mount P/S in place of 1 of the other
boards
Can place backup battery in place of 1 of the other boards
Small Enclosure (PREM-ANCSM)
•
•
•
W10” x H8 ½” x D2
Holds: 1 of the following:
o IP Controller
o 2 Reader Controller
o 2 Reader Board
o 16 Input Board
o 16 Output Board
1 or 2 – 1 Reader board using adapter plate