Transcript 幻灯片 1

Power Supply Related Regulati
on Update and EN 60335 Home
appliance FAQ
Wen Wu
PART I: Regulation Update
LVD
EN61347-1, 2-13
Conducted/Radiated emission
EN55015
Electro-Magnetic Interference
(EMI)
Harmonic current
EN61000-3-2
Voltage flicker
EN61000-3-3
ESD air/contact
EN61000-4-2
CE
EMC
RF field susceptibility
EN61000-4-3
Electrical fast transient/burst
immunity
EN61000-4-4
Electro-Magnetic Susceptibility
(EMS)
Starting time
Ecodesign
Standby power
RoHS
Power factor
EMS for general lighting
purposes
EN61547
Surge susceptibility
EN61000-4-5
Conducted susceptbility
EN61000-4-6
Magnetic field immunity
EN61000-4-8
Voltage dip, interruption
EN61000-4-11
LED Safety update






Version Update
Latest LED safety:
EN 61347-1:2008/A1:2011
EN 61347-1:2008/A2:2013
EN 61347-2-13:2006
EN 61347-2-13:2014
DOP 2012/2/1 ; DOW 2014/2/1
DOP 2013/10/1 ; DOW 2016/1/1
DOP 2007/4/1 ; DOW 2009/7/1
DOP 2015/7/8 ; DOW 2017/10/8

IEC61347-1:2007+A1:2010 (ed2.1) DOP 2011/11/29
IEC61347-1:2007+A2:2012 (ed2.2) DOP 2012/11/27
IEC61347-1 (ed 3.0) (drafting)(Group TC/SC 34C)
IEC61347-2-13:2006 (ed 1.0) DOP 2006/5/5
IEC61347-2-13:2014 (ed 2.0) DOP 2014/9/3

ENEC (EN 61347 + EN 62384)




LED Safety update

Requirement Difference

Stricter safety distance and withstand voltage








Non-SELV
SELV
: 4U+2000
: 3000 (or 4200 when W.V >300)
Transformer DTI refer to 61558-1
Ground trace test
AC discharge refer to 60598-1 : < 60Vpk after 1sec.
Touch current at SELV <0.7mA peak
Cross capacitor can be Y2 x 2 or Y1 x 1
Symbol:


Protective Earth
Double insulation : Built-in:
Independent :
LED Safety update





Mean Well Action
All LED update to A2 version
New design follow latest IEC requirements
Expanding ENEC models
Actively checking IEC 3rd edition development status
LED EMC update




EN61000-3-2 harmonic current
EN61000-3-2 describes the permissible harmonic current emissi
ons for devices with an input current of up to 16 A per phase.
LED driver with less than 25Watt has no limit values for harmoni
c.
In case the Driver has an effective input power larger than 25 W,
the limit shown in the Table 2 has to be achieved.
Harmonic order
n
2
3
5
7
9
11 ≤ n ≤ 39
(odd harmonics only)
* λ is the circuit power
factor
Maximum permissible harmonic current
expressed as a percentage of the input
current at the fundamental frequency
%
2
30 ⋅ λ *
10
7
5
3
LED Ecodesign update



Power factor requirement
The power factor requirement of non-directional and directional
LED lamps with integrated control gear is specified shown in Tab
le.
Although EN61000-3-2 harmonic current of EMC directive does
not regulate LED driver less than 25Watt, it is however regulated
in the directive of Ecodesign.
Effective input power
P
P≤ 2W
2W<P≤5W
5 W < P ≤ 25 W
P > 25 W
Power factor
requirement
No requirement
>0.4
>0.5
>0.9
LED Ecodesign update

Standby power requirement

Note that Standby is different than No load Power.
ITE Safety update










Version Update
Latest IT safety:
EN 60950-1:2006+A11:2009+A1:2010
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
EN 60950-1:2006/A2:2013 DOW 2016/7/2 ← last ver. of 60950
EN 62368-1: 2014
DOP 2015/6/20 DOW 2019/6/20
UL 60950-1 Ed. 2
2014/10/13 ( equal to IEC60950-1:2005/A2:2013)
IEC 60950-1:2005/A2:2013
IEC 62368 (ed2) (TC 108)
DOP: 2014/2/26
62368 = 60950+60065
Safety of electronic equipment within the field of audio/video,
information technology and communication technology
ITE Safety update






Requirement Difference
Varistor limitation for (60950-1:2006/A2:2013)
Lower safety distance requirement
Primary to Secondary withstand voltage 5.09KV
Discharge resistor add Thermal cycling test
Ground bonding test
ITE Safety update




Mean Well Action
New model or new update to EN 60950:2006/A2:2013
Old certificates with A12 valid until 2016, update by request
Mean Well plan to cut-in 62368 from 2017/Q4
Mean Well enclosed type RSP-150 series has UL62368
PART II: 60335
Introduction
WHY ?
EN60335
Coffee
machine, Floor cleaning, Vending machine, …
They are all around you
 How
do we get into this market !
Contents
EN 60335 Overview
 Design in with Modification
 60335 FAQ
 MWEU Technical Support

60335 Overview

60335 Household and similar electrical appliance







60335-1 General requirement
60335-2-xx Particular requirement
60335 is approved to the system
No“-2-xx”for switching power supply
Transformer design refer to 61558 standard
Safety distance in general less than*
60950/61558/61347*
and there are special requirements….
*When system without opening. i.e. PD2 condition.
60335 Special Requirements

Pollution degree


Pollution degree 2 (PD2) for air-tight enclosure
Pollution degree 3 (PD3) for system with opening
*Requirement
from TUV

2 protective impedances
AC discharge
Flammability
Limited current test…

Mean Well has dedicate safety team to check for you




Let us know the electrical/mechanical spec. and we c
an provide you good suggestions
60335 Design-in Guidelines

Example Applications:







60335-2-29 Battery chargers
60335-2-30 Room heaters
60335-2-33 Particular requirements. Coffee mills and
coffee grinders
60335-2-67 Floor treatment and floor cleaning
machines for industrial and commercial use
60335-2-75 Commercial dispensing appliances
and vending machines
60335-2-89 Commercial refrigerating appliances
with an incorporated or remote
refrigerant condensing unit or compressor
60335-2-103Drives for gates doors and windows.
60335 Design-in Guidelines

Standard models that can already meet 60335-1





Possible to modify



RSP-75~150
HLG/N-40/60, NPF/PWM/OWA-90(E)*
Medical with MOPP**
PB-300~1000 (60335-2-29)
LED ( 61347 approved, IP6X models)
Medical MOOP models
Other possibility

Please check with MWEU
*AC discharge and touch current need to be re-confirmed.
**AC discharge and output isolation need to be re-confirmed.
60335 Modification


Application: Cleaning machine
Requirement:

System should meet 60335
24V/300W, enclosed type

PSU meet 60335-1


MW proposal:
MSP-300-24 modify cross capacitors x 2
Medical with MOOP

Result:
Original CB as reference.
Certify body approved system for 60335
60335 Modification


Application: Lighting for Refrigerator
Requirement:

System should meet 60335
24V/240W, LED power supply

PSU meet 61347 and 60335-1 + 60335-2-89


MW proposal:
HLG-240H-24 modify cross capacitors x 2
LED with IP67

Result:
MW is applying 60335 certificates with -1 and -2-89.
Customer will higher flexibility and lower cost when they use the
same PSU in their different projects
60335 Modification


Application: coffee machine
Requirement:

24V/150W, enclosed type or open frame
No load power consumption

PSU meet 60335-1


MW proposal:
RSP-150-24 standard unit
61558 (PD3) with design refer to 60335-1

Result:
Customer prefer RS-150 for cost concern.
They get confirmation from certify body that RS-150 with 2 cross
capacitors is sufficient for their approval.
MW modify according to customer requirement but do not
guarantee 60335.
60335 FAQ
60335 Q&A


Questions:
Can I apply 60335 on RSP-150 series?
Answer:
Yes RSP-150 can apply for 60335-1 CB report and
certificate. But without -2, it is not a complete LVD
safety, so the CE will still base on 60950/61558
60335 Q&A


Questions:
Why does Mean Well apply 61558 for RSP-150
Answer:
In the safety standard development, 61558 is more close to
60335. for example, 60335 refer to 61558 for the transformer,
further, 61558 also has a more strict safety distance rules.
A power supply with 61558 can easily meet 60335-1
requirements if the special terms on 60335 are being concerned.
Which means when customer taking a 61558 PSU to the certified
body, they can skip a lot of test and only focus on the difference.
Save time and money.
60335 Q&A


Questions:
What is Mean Well plan for 60335 power supply
Answer:
Refer to Wen/Ted. We will create a series of non-PFC enclosed
type <150W for 60335-1. LRS-150/100/…
New medical open frame type will also take 60335-1 into
concern.
60335 Q&A


Questions:
Can RS-50 (60950) apply for 60335
Answer:
No it is not possible without major redesign of transformer and
PCB. At least it is how Mean Well understood it. However, it is
always suggested to check with customer and their testing
house what is their opinion about meeting 60335-1; sometimes
there is a surprise.
60335 Q&A


Questions:
How about the EMC for Household Electronics ?
Answer:
The corresponding EMC regulation is EN 55014.
It is more or less similar to 55011/55022, but again with
additional tests. PSU that can pass 55011/55022 has very
high chance to pass 55014 also.
60335 Q&A


Questions:
EN 62233 what is that ?
Answer:
Basically, it tells you whether the EM wave of the
product at your hand is harmful to you…
EN 62233 : Measurement methods for
electromagnetic field of household appliances and
similar apparatus with regard to human exposure.
Previously defined in 50366, is a standard to evaluate the
influence of EM field to human. It is a must for GS mark product.
The requirements are different for various applications.
Final evaluation should be done at system level.
60335 Q&A


Questions:
Does USA also apply 60335?
Answer:
There is UL 60335 available but it is not popular.
In general, for US market, the power supply can always apply
UL1012 or UL1310. For the final application, there might be
other specific UL standards for that.
PART III: MWEU Technical Support
Mean Well Technical Support

Highlighted projects:






FAE+TS+RMA





PLP series input 305V, 60335-1 for Frigoglass
HLG-240H apply 60335 refrigerator cert. (60335-2-89)
HLG-120H/185H-42 for 60335-1_60335-2-29
OWA with 61558 and 60335-1
NFM-20, RPS-300, …
Customer visit and onsite support
Technical article
Modification
Failure analysis and application issue
Check with MWTS for project support !
Q& A