Piezoelectric
Characterization in an AFM
Joe T. Evans, Jr,
Radiant Technologies, Inc.
Radiant Technologies, Inc.
Introduction
• Radiant has developed a special packaged die containing
thin PZT film capacitors constructed to aid piezoelectric
characterization in an AFM.
• The capacitors have exposed top electrode and exposed
PZT surfaces over bottom electrode to allow PFM
characterization.
• The devices may also be used to execute more
conventional piezoelectric measurements such as the
butterfly loop.
• All of the characterization techniques that may be
executed on one of these reference devices will be
described in the following presentation.
Radiant Technologies, Inc.
2
Foundation Process
One half of a
micrometer of PZT,
TiOx, & glass as
protection
Half of a
micrometer of
Silicon Dioxide as
a foundation
Top
Electrode
Bottom
Electrode
Ferroelectric
material
Silicon wafer
• Radiant has an established process for thin PZT film
capacitors with platinum electrodes, top glass passivation,
and chrome/gold metal interconnect (not shown).
Radiant Technologies, Inc.
3
20/80 PZT
P o la r iz a t io n (µ C /c m 2 )
80
70
60
50
40
30
20
10
0
-1 0
-7 .5
-5 .0
-2 .5
0 .0
V o lt a g e
2 .5
5 .0
7 .5
• Typical hysteresis loop for Radiant 0.26 20/80 PZT with
platinum electrodes.
Radiant Technologies, Inc.
4
Reference Process
Top
Electrode
Bottom
Electrode
Ferroelectric
material
Silicon wafer
• The reference is fabricated without the ILD passivation
layer to allow electrical access directly to the top electrode.
Radiant Technologies, Inc.
5
The Reference Die
The completed die has multiple capacitors ranging from
10x10 up to 100,0002. The film is 0.26 20/80 PZT.
Radiant Technologies, Inc.
6
Packaging
The die is mounted on a TO-18 transistor header without a lid. The
bottom electrode is bonded to the COMM pin. Any of the other
capacitors may be bonded to the other two free pins.
Radiant Technologies, Inc.
7
Packaging
TO-18
Cap A
Common Cap B
Top view
COMMON
CAP A
CAP B
CASE
The TO-18 package provides a convenient format for handling and
connecting to the integrated capacitors. The packages shown above
have lids. The PFM references do not.
Radiant Technologies, Inc.
8
Mounted in the AFM
• The header (package without a lid) can be soldered to an
experiment board or placed in a socket for alignment under the
AFM cantilever.
Radiant Technologies, Inc.
9
Electrical Connection
With a conductive cantilever tip, the PZT over the bottom electrode
without a top electrode my be scanned and poled.
Radiant Technologies, Inc.
10
PFM of Un-electroded PZT
The un-electroded PZT over bottom electrode as made exhibits the
theoretical distribution of 50:50 polarization orientation.
Radiant Technologies, Inc.
11
PFM of Un-electroded PZT
The un-electroded PZT over bottom electrode as made exhibits the
theoretical distribution of 50:50 polarization orientation.
Radiant Technologies, Inc.
12
PFM of Un-electroded PZT
Using a
conductive tip,
the exposed
PZT over
bottom
electrode can
be poled UP or
DOWN with
the application
of a bias
voltage.
In the image above, the rim outside the poled region is virgin and
was not poled in the opposite direction.
Radiant Technologies, Inc.
13
PFM of Electroded PZT
The electroded PZT may be electrically stimulated either with a
conductive tip or through one of the TO-18 package pins.
Radiant Technologies, Inc.
14
Electrical Connection
TO-18
Bottom electrode
Cap A
Common Cap B
PFM Stimulus Signal
The common is the bottom electrode connection. The PFM signal
can be applied to one of the capacitor top electrodes through a
package pin. In this situation, the cantilever tip provides
displacement information only.
Radiant Technologies, Inc.
15
Electrical Connection
TO-18
Bottom electrode
PFM Stimulus Signal
Cap A
Common Cap B
The common is the bottom electrode connection. The PFM signal
can be applied to one of the capacitor top electrodes through a
package pin. In this situation, the cantilever tip provides
displacement information only.
Radiant Technologies, Inc.
16
PFM of Electroded PZT
Phase maps of the same region poled UP and DOWN yields
information about the presence and distribution of defects.
Radiant Technologies, Inc.
17
PFM of Switching Polarization
P o la r iz a t io n (µ C /c m 2 )
80
70
60
50
40
30
20
10
0
-10
-7.5
-5.0
-2.5
0.0
2.5
V o lt ag e
5.0
7.5
All of the new PFM tools may be applied to the reference.
Radiant Technologies, Inc.
18
PFM of Switching Polarization
Asylum Research
tested a new
software protocol to
capture this movie.
The data took three
hours to collect.
The software
protocol used
landmark
recognition to
correct any X:Y
drift of the stage
between scans.
Radiant Technologies, Inc.
19
Reference Applications
With its high signal-to-noise ratio, a reference may be used
for a variety of applications:
•
•
•
•
•
Activation at less than 10 volts.
Verification of equipment operation
Verification of procedures
Evaluating test procedures on a known-good sample
Materials and polarization switching studies
Radiant Technologies, Inc.
20
Other Measurements
AFM Output Signal
By connecting the Z-output of an
AFM to a polarization tester, a large
array of other tests may be executed
to parallel the PFM measurements.
AFM
Conductive
Tip
Polarization Tester
SENSOR
DRIVE
Insulator
RETURN
Chuck
A wire must run directly
between system grounds.
Radiant Technologies, Inc.
21
Butterfly Loop
1.0 PNZT with platinum electrodes, shown above, moves
approximately 15 Angstroms at 20 volts. The 0.26 20/80 PZT is
expected to move approximately 3 Angstroms at 9 volts.
Radiant Technologies, Inc.
22
Electrical Properties
Hysteresis Parameters
uC/cm^2, uA/cm^2, uF/cm^2
50
40
30
20
10
Rhyst
0
-6
-4
-2
-10
0
2
4
6
SW CV*10
nSW CV*10
-20
SW IV*2.5
-30
nSW IV*2.5
-40
Volts
• Using the AFM as a probe station, the polarization, remanent
polarization, small signal capacitance, and leakage vs voltage
may be measured on the same sample as are the piezoelectric
measurements.
Radiant Technologies, Inc.
23
Conclusion
• It is now possible to measure all electrical and
piezoelectric properties on a single capacitor.
–
–
–
–
–
–
–
Polarization hysteresis
Small signal capacitance hysteresis
Current vs Voltage
Butterfly loop
Small signal displacement
PFM amplitude and phase maps
PFM d33 loop
• Measurement and comparison of these measurements on a
single sample will improve our understanding of the nature
of piezoelectric materials.
Radiant Technologies, Inc.
24
Acknowledgements
An Asylum Research MFP-3D AFM with an Arc2 controller
were used to capture the images in this presentation. Radiant
would like to acknowledge Asylum Research and its employees for
their assistance in this work.
Radiant Technologies, Inc.