HMIs
HMIs
Human Machine Interfaces
HMIs
Human Machine Interfaces
MP+
Terminals
TCP / IP
HMIs
The E-series of HMIs
E900VT
E910
E900
E710
E50
E100
E300
E200
E600
E700
HMIs
E50 - low cost
Background lit text display 2x16
4 function keys
RS422 with RS232 in the same Dsub
+5 VDC, external or from PLC
Text blocks
HMIs
E100 - small but strong
Background lit text LCD-display
2 rows x 20 characters
4 function keys
Text blocks
Time channels
Real-time clock
Recipe handling
RS-232C and RS-422 ports
+5 VDC, external or from PLC
64 Kbytes flash memory
Transparent mode
HMI Tools support
HMIs
E200 - As simple as it can be
Background lit text LCD-display
4 rows x 20 characters, 5 mm text height
5 function keys
5 LEDs (two colour)
Text blocks
Time channels
Real-time clock
Recipe handling
RS-232C and RS-422 ports
64 Kbytes flash memory
Transparent mode
HMI Tools support
HMIs
E300 - Low-end graphic
Background lit graphic LCD-display
Two colours, 240 x 128 pixels
8 function keys
16 LEDs (two colour)
Graphic and text blocks
Time channels
Real time trends
Recipe handling
RS-232C and RS-422 ports
1 expansion slot
128 Kbytes Flash memory, expandable to 8Mb
Transparent mode
HMI Tools and TCP/IP support
HMIs
E600 - one step up
Background lit graphic LCD-display
Two colours, 240 x 128 pixels
16 function keys
16 LEDs (two colour)
Graphic and text blocks
Functionality as E300
Historical trends
RS-232C and RS-422 ports
1 expansion slot
256 Kbytes Flash memory, expandable to 8Mb
Transparent mode
HMI Tools and TCP/IP support
HMIs
E700 - A trend composer
Background lit graphic LCD-display
256 colours, 320 x 240 pixels
16 function keys
14 LEDs (two colour)
Graphic and text blocks
Functionality as E600
RS-232C and RS-422 ports
2 expansion slots
400 Kbytes Flash memory, expandable to 8Mb
Transparent mode
HMI Tools support and TCP/IP support
HMIs
E710 - with new hardware
Background lit graphic touch LCD-display
256 colours, 320 x 240 pixels
8 function keys
8 LEDs (two color)
Graphic and text blocks
Functionality as E700
RS-232C and RS-422 ports
2 expansion slots
400 Kbytes Flash memory, expandable to 8Mb
Transparent mode
HMI Tools support and TCP/IP support
HMIs
E900 - Even bigger
Background lit graphic colour display
256 colours TFT, 640 x 480 pixels
22 function keys
20 LEDs (two colour)
RS-232C and RS-422 ports
2 expansion slots
1.6 Mbytes Flash memory, expandable to 8Mb
220 VAC power supply
Transparent mode
HMI Tools and TCP/IP support
HMIs
E910 - touch it!
Background lit graphic touch display
256 colours TFT, 10,4”, 640 x 480 pixels
RS-232C and RS-422 ports
2 expansion slots
1.6 Mbytes Flash memory,
expandable to 8Mb
Dimensions 290 x 250 x 105 mm
220 VAC power supply
Functionality as E900
24VDC version now available!
HMIs
E900VT - more inputs...
Background lit graphic TFT-display
256 colours, 10,4”, 640 x 480 pixel
22 + 28 function keys ( IFC-64E )
20 two color + 28 green LEDs
RS-232C and RS-422 ports
1 expansion slot
1.6 Mbytes Flash memory,
expandable to 8Mb
220 VAC power supply
Functionality as the E900
HMIs
E610 - preliminary
Touchversion of E600
B/W LCD display
Compact
Low price
Release Q4 2000
HMIs
Expansion cards
Memory expansion with IFC-MC
Increase project memory with up to 8Mb
Back-up of recipes and projects
Transfer of files to other terminals
Profibus DP IFC-PBDP
Slave connection to Profibus DP
TCP/IP network IFC-ETTP, IFC-ETCX
Terminal network and Internet
enable via Ethernet
HMIs
Expansion cards
External function keys with IFC-128E
For connection of up to 128 extra function-keys
Parallel printer with IFC-PI
For connection of an parallel printer
A-bus interface IFC-GA (E900/E910 only)
Direct connection to the A-bus
HMIs
IFC-PI - Parallel printer port
Print outs of graphic and text blocks, reports and
alarm lists
– Graphics requires a HP PCL5, HP PCL6 or Epson FX80
compatible printer
– If IFC PI is used a printer can not be connected to the RS232 port
E300 and E600 have no support for HP PCL5/6
printers
 Black and white print outs only
HMIs
IFC-PI - Parallel printer port
Connectable to
–
–
–
–
–
–
E300 version 4.0 or higher (only with Epson FX-80)
E600 version 4.02 or higher (only with Epson FX-80)
E700 version 4.0 or higher
E710 version 4.0 or higher
E900 version 1.01 or higher
E910 version 4.02 or higher
HMIs
IFC-GA - Direct bus connection
With the expansion card, IFC-GA, and the businterface A7GT-BUS installed, you can connect the
E900 and E910 terminals directly to the base unit on an
A(nS)-system.
The communication between the PLC and the
terminal will be very effective with the IFC-GA, because
the terminal communicates directly with the A-bus on
the PLC.
The standard RS-232/422 ports
will be free for other equipment.
HMIs
The new concept
Before:
Today:
Omron.dll
Omron.pdf
Project
Project
Driver
Terminal code
+
Drivers
Terminal code
Omron.hlp
HMIs
The new concept
Downloadable drivers
WEB
All terminals in the E series from version 4.0
The driver and the system program are
separated in the terminal
New drivers can be used without a
update of MP+
Installation via Internet using MP+
or from floppy (first download from web)
Current driver is automatically transferred to
the terminal by MP+
New standard cables to new PLC systems
Manual in pdf-format to each driver
HMIs
2 ports gives you freedom
Transparent mode
Communication with
the PLC system via the
terminal
Mitsubishi
Omron
Matsushita
Serial printer
No protocol mode
- Communication with external units i.e. barcode readers
HMIs
Transparent mode
Reach PLC through terminal
GPP/WIN
in operation
MM+
Online changes
Easier troubleshooting
HMIs
Are you an individual?
Individual customised products - from simple panels to
PC platforms
Integration into your machine design
Customised OEM products, your operator control
concept in style and functionality
What can we offer you:
• Individual design and front layout
• Modular Hardware
• Flexible Software
• We will implement your requirements
- So You can be successfully in business
• Professionalism and competence is our name
And You:
Be an individual...
HMIs
The lifecycle - Of a terminal...
Even at the design stage we try to think in a long time
perspective
The choose of :
–
–
–
–
Components
Material
Handling
Transports
Recycled
Recycling
Minimum
And in the end...
We take care of old used products, and sees that
every part is handled in a minimum non-polluting way.
As our contribution to the environment .
HMIs
Do it the hard way...
The usual information way
Operator
RUN
STOP
FWD
REV
Process/
Machine
HMIs
Or the easy way!
HMI as information provider!
Operator
HMI
Process/
Machine
The HMI-solution gives you:
Information in a easy way
The Information will be clear and in right time
Easier to determine when changes occur
HMIs
You will save:
Money
Effective
Flexible
Simplicity
Time
Easy - Handle
Quick - Learn
Simple - Install
Right information - In Right Time
HMIs
Basic functions
Alarm handling
Recipe handling
Realtime clock
Time channels
Trend diagram
Password handling
6
HMIs
Operator interface
Text
Graphic
Colors
Touch screen
LEDs
Functionkeys
Printouts
E
710
HMIs
Mac Programmer+
Easy to use
Windows 95, 98, 2000 and NT
Documentation
Back-up
Full support for Windows
copy/paste
Toolbox and ToolTips
Multiple project can be open at the same time
Compatible name list with MELSEC MEDOC
and MELSEC MEDOC +
Support for MXChange
HMIs
Structure
Using a tree structure when developing a
project
HMIs
Block manager
Simplifying the handling of the blocks.
Gives the engineer a visual overview how the
project is created.
HMIs
Object based
All object data is stored in the terminal
The signals is configured directly in the object
No PLC-programming is needed*
Only the object´s which is viewed on the screen is
updated
* except Profibus
HMIs
Downloadable drivers
Now you are just a click from upgrading your
drivers
HMIs
The Internal Name list
For easy changing of different PLC devices
HMIs
Message library
Manoeuvrable message objects
– 64 libraries can be manoeuvrable with 512 texts,
40 characters
– Values between 0-65535 can be linked with texts
HMIs
News in Mac Programmer+
32-bit version to Windows 95, 98, 2000 and
NT
Supporting downloadable drivers
Supporting TCP/IP network
Installation from CD
HMIs
News in Mac Programmer+
New configuration of peripheral units
Acknowledge of individual alarms
from the PLC system
Alarm on
the negative edge
HMIs
More news!
Modem handling in all terminals
except E50
– Call up with the terminal
– 10 different numbers stored in the
terminal
– 1 number stored in the PLC system
Larger size on the alarm text in
E900
System monitor in E700, E710,
E900 and E910
HMIs
More news!
Show terminal in text blocks
Printing text strips to all terminals from MP+
Improved project documentation in print-outs
Use terminal font in MP+
Cursor colour in the alarm list can be
changed
HMIs
And more….
Recipes sorted in alphabetic order
Turning off printing from the PLC system to
avoid conflicts when transparent mode is used
Min- and max limits on numeric
objects in graphic blocks
The alarm group name can contain national
characters
New data formats
– HEX 16-bit, 32-bit
– BCD 16-bit, 32-bit
– Float without exponent
HMIs
The Installation CD
MAC Programmer+ 32-bit
HMI Tools 32-bit
All current drivers
Manuals to all products
–
–
–
–
E-series and MAC-series
Expansion cards
Installation manuals
Drivers
Floppy-copying of Full version, Demo and
Transfer
HMIs
New manuals
New E-series manual
– The same manual to all E-terminals and MP+
New installation manual
– The same manual to all E-terminals
– Enclosed with all terminals
Separate manual to each driver
– Downloaded with the driver in MP+
All pdf-manuals are available at WEB-site
and on installation CD
HMIs
HMI Tools
Windows 95, 98, 2000 and NT
Transferring of recipes, trends and alarm lists
Downloading of system programs
Communication via modem
MP+ Transfer is a separate program
Why choose an operator
terminal from Mitsubishi?
High Quality
User friendly
Functionality
One Software for all terminals
Possibility to upgrade the
operating system
High quality support
And of course the openness
HMIs
HMIs
Support at the web
Downloadable:
Latest versions of software's
Demo Projects
Product news
Drivers
Manuals
Manufacturer´s declarations
Upcoming features
Application examples
FAQ
http://www.mitsubishi.co.uk/automation
http://www.e-terminals.com
HMIs
Drivers & Connections
HMIs
Drivers
Melsec A (C24*, CPU, E71**
or Profibus DP**)
Melsec A-bus (A-bus*)
Melsec A CC-Link connection
(AJ65BT-G4)
Melsec FX (CPU or
485ADP*)
Melsec QnA (QC24*, QCPU*
or Profibus DP**)
Freqrol FR-A/E
Melservo MRJ2CS100
* Can not be used with E50
** Can not be used with E50, E100 or E200
HMIs
Drivers
SIMATIC S5 (3964R/RK512*,
PG-port* or Profibus DP**)
SIMATIC S7 (3964R/RK512*,
MPI*, PPI or Profibus DP**)
* Can not be used with E50
** Can not be used with E50, E100 or E200
HMIs
Drivers
ABB
DVT Vision System
– SattCon (Comli master*)
Allen-Bradley
– Micrologix (DF1)
– SLC500 (DF1 or DH485**)
Control Techniques
– Unidrive (ANSI*)
Delta Tau
– PMAC, UMAC (ASCII*)
Demonstration driver
– Internal in the HMI
– SmartImage Sensor (ASCII
or TCP/IP**)
Festo/Beck
– IPC, FEC series (FXT CI*)
GE Fanuc
– Series 90 (SNPX)
Hitachi
– H Series (HCOM*)
IAI
– SuperSEL (Serial*)
* Can not be used with E50
** Can not be used with E50, E100 or E200
HMIs
Drivers
Idec
Matsushita
– FA-1/2/Junior/Micro1 (FAseries 1:1 expanded*)
– FA-3 (FA series 1:1*)
– MICRO3/3C (Micro
Computer Link)
Klockner Moeller
– PS4 series (SUCOM-A*)
Koyo
– Direct logic series
(DirectNET* or K-sequence)
– FP-series (MEWTOCOLCOM)
Modicon
– All PLC types (Modbus
master ASCII/RTU or
Modbus slave RTU*)
MXCC
– VLC (Serial* or Profibus
DP**)
Omron
– All PLC types (Hostlink)
* Can not be used with E50
** Can not be used with E50, E100 or E200
HMIs
Drives
SAIA
– PCD series (SBUS*)
SEW Eurodrive
– Movidrive (Movilink*)
– Movidyn (Movidyn*)
– Movitrac (Movitrac*)
VT100
Yaskawa
– MP9xx series (MemoBus
master RTU*)
Telemecanique
– TSK series (UniTelway*)
Toshiba
– PROSEC T-series
(Computer Link)
… and more will come!
* Can not be used with E50
** Can not be used with E50, E100 or E200
HMIs
How to make a connection
HMIs
Mitsubishi - E71 driver
PLC-program
E71-profile
TCP/IP
or
UDP/IP
Server
BDTP
Client
Client
IFC-ETCX
The PLC-systems in
Melsec A/QnA(S)-series via
AJ71E71 or AJ71QE71
using the ASCII protocol.
All E-series terminals can
be used, with the exception
of E100 and E200.
Requires Ethernet card.
HMIs
Mitsubishi - MELSERVO
All E-series terminals can be used
MR-J2-C-S100
RS422 or RS232 connection
Multidrop of up to 32 servos possible
Read/Write all inverter parameters,
digital/analog signals, alarm codes
All E-series functionality available
(text/graphic, trending, recipe, reporting,
networking …)
HMIs
Mitsubishi - MELSERVO
Point-to-point
RS-232
Default station number
Multidrop
RS-485
RS-422
Cable as drawing in the manual
HMIs
FREQROL FR-A/FR-E
All E-series terminals can be used
FR-A and FR-E series
RS422 or RS232 connection
Multidrop of up to 32 inverters possible
Read/Write all inverter parameters,
digital/analog signals, alarm codes
All E-series functionality available
(text/graphic, trending, recipe, reporting,
networking …)
HMIs
FREQROL FR-A/FR-E
Point-to-point
RS-422
CAB-9
PU-Port
SC-FRPC
RS-232
Multidrop
RJ45
Default station number
FR-A5NR
RS-422
Cable as drawing in the manual
HMIs
MXCC <-> E-series alt.1
PROFIBUS-DP connection
E300-900 can be connected
MXCC-program handles the
HMI-profile
HMIs
MXCC <-> E-series alt. 2
RS232
I/O-bus
Serial connection
MXCC-program (Profile)
All E-series HMIs can be
used
Low price connection
Survives NT-crash
Terminal network through
Ethernet possible
HMIs
ABB - COMLI Master
Supports multidrop
Nod ID:
CAB8
CAB-8
RS-422
RS-485
Cable as drawing in the manual
HMIs
Allen-Bradley DF1 Micrologix
The PLC-systems in the Micrologix 1000-series
CRC-16 checksum
Full duplex
This node = Terminal
Remote node = PLC
CAB-2
8-pol
Mini-Din
RS-232
HMIs
Allen-Bradley DF1 SLC-500
The PLC-systems SLC 500, SLC 5/01, SLC 5/02,
SLC 5/03 and SLC 5/04
Requires the module 1747-KE, 700 DEM
(The DF1 connection at SLC 5/03 and SLC 5/04
is not recommended because of more disturbance)
CRC-16 checksum
Full duplex
This node = Terminal
Remote node = PLC
DH-485
CAB-5
Cable 1747-C13
from Allen-Bradley
RS-232
HMIs
Control Technique - UNIDRIVE
All E-series terminals can be used
Inverters in the Unidrive series with
serial interface i. e. UD 71.
RS422 or RS232 connection
Multidrop of up to 32 servos possible
Read/Write all controllers parameters,
digital/analog signals, alarm codes
All E-series functionality available
(text/graphic, trending, recipe, reporting,
networking …)
HMIs
Control Technique - UNIDRIVE
Point-to-point
RS-422
Default station number
Multidrop
RS-422
CAB8
CAB-8
RS-422
RS-485
2-wire
4-wire
RS-422
Cable as drawing in the manual
HMIs
Delta Tau - PMAC/UMAC
All E-series terminals can be used
RS422 or RS232 connection
Point to Point or Multidrop
Read/Write all controllers
parameters, digital/analog signals,
alarm codes
All E-series functionality available
(text/graphic, trending, recipe,
reporting, networking …)
HMIs
Delta Tau - PMAC/UMAC
The Positioning-system in Delta Tau PMAC/UMACseries
Default station number
MAC 40+-CAB
RS-422
Multidrop is performed by a band cable between the PMAC/UMAC systems
HMIs
Demonstration driver
Driver for demonstration without PLC-system
99 M-coils
99 data registers
4 counters
4 timers
HMIs
GE Fanuc SNPX
The terminals supports all GE Fanuc PLC systems,
connected via the SNPX protocol.
SNP ID number
CAB-4
RS-422
No PLC-program
requires for the
communication
HMIs
Idec - FA series
The PLC-systems in Idec FA-series

Idec
8-pol
connector
RS-422

RJ11
RS-422
Cable as drawing in the manual
 Contain electronically devices,
se driver manual
HMIs
Idec - Micro 3-series
The PLC-systems in Idec Micro 3-series
Default station number
8-pol
Minidin
I
Alt.
I
CAB-8
CAB8
RS-485
RS-422
8-pol
Minidin
RS-232
Cable as drawing in the manual
HMIs
Koyo - DirecNet & K-Sequence
Koyo Direct Logic Series K-Sequence PLC
Koyo via the DirectNET
Default station number
15-pol
RS-422
15-pol
RS-232
RJ12
RS-232
Cable as drawing in the manual
HMIs
Matsushita - FP series
The PLC-systems in Matsushita FP-series via the
MEWTOCOL-COM protocol
Default station number
15-pol
9-pol
RS-422
5-pol
Mini-Din
RS-232
RS-232
Cable as drawing in the manual
HMIs
Modbus ASCII / RTU
Supports Multidrop
Default station number
CAB8
CAB-8
RS-422
RS-485
Cable as drawing in the manual
HMIs
Omron Hostlink
The terminals supports all Omron PLC systems,
connected via the Hostlink protocol.
Supports transparent mode
Default station number
No PLC-program
requires for the
communication
CAB-3
RS-232
HMIs
Siemens SIMATIC S5 PG1/AS511
The PLC-systems SIMATIC S5 90, 115, 135 and 155
No PLC-program
requires for the
communication
CAB-7
RS-422
Siemens Converter
6ES5 734-1BD20
CAB-1
RS-232
HMIs
Siemens SIMATIC S5 3964R/RK512
The PLC-systems SIMATIC S5 90, 115, 135 and 155
Requires communication card CP525
Writing is only possible to DB, other devices can only
be read
The terminal
Higher priority=Master
PLC
3964R / RK512=Slave
CAB-6
RS-422
Null modem
CAB-5
RS-232
HMIs
Siemens SIMATIC S5 Profibus DP
The PLC-systems SIMATIC S5 90, 115, 135 and 155
Requires Profibus DP interface (IFC-PBDP)
IFC-PBDP
PLC program
HMI-profile
Requires timedelay
in connection with
fast CPU:s
HMIs
Siemens SIMATIC S7 MPI
The PLC-systems SIMATIC S7 300- and 400-series
The MPI station number
of the terminal
The MPI stationnumber
of the PLC system
Highest MPI address
CAB-6
CAB-11
RS-422
+
CAB-5
RS-232
HMIs
Siemens SIMATIC S7 PPI
The PLC-systems SIMATIC S7 200-series
The station number of the terminal
The stationnumber of the PLC-system
Highest PPI address
Only the terminal
can be Master in
the network
PPI-Port
CAB-8
RS-422
Cable as drawing in the manual
HMIs
Siemens SIMATIC S7 3964R/RK512
The PLC-systems SIMATIC S7 300- and 400-series
Requires communication card CP341
Writing is only possible to DB, other devices can only
be read
The terminal
Higher priority
Master
PLC
3964R/RK512
Slave
CAB-5
RS-232
HMIs
Siemens SIMATIC S7 Profibus DP
The PLC-systems SIMATIC S7 300- and 400-series
Requires Profibus DP interface (IFC-PBDP)
IFC-PBDP
PLC-program
HMI-profile
HMIs
Toshiba
The PLC-systems in PROSEC T-series via Multidrop
connection
Default station number
The Computer Link
protocol
RS-232
RS-485
RS-485
RS-422
CR-01
MAC30/40-CAB
CR-01
Cable as drawing in the manual
RS-422
HMIs
Cables
CAB1
– cable to connect Siemens SIMATIC S5/PG1 via
Siemens Converter to the RS-232-port on the
terminals in the E-series. 0,5 m.
CAB2
– cable to connect Allen-Bradley's PLC system
Micrologix to the RS-232-port on the terminals in
the E-series. 3 m.
CAB3
– cable to connect Omron PLC system via the
Hostlink protocol to the RS-232-port on the
terminals in the E-series. 3 m.
HMIs
Cables
CAB4
– cable to connect GE Fanuc PLC system via the
SNPX protocol to the RS-422-port on the
terminals in the E-series. 3 m.
CAB5
– cable to connect Siemens SIMATIC S7/MPI via
Siemens HMI Adapter, Siemens SIMATIC
S7/3964R, Siemens SIMATIC S5/3964R and
Allen-Bradley/DF1 PLC-systems to the RS-232port on the terminals in the E-series and to
connect a PC to the RS-232-port on the terminals
in the E-series. (MAC PROG/9-CAB) 3 m.
HMIs
Cables
CAB6
– cable to connect Siemens SIMATIC S7/MPI via
Siemens HMI Adapter, Siemens SIMATIC
S5/3964R and PC to the RS-422-port on the
terminals in the E-series. 3 m.
CAB7
– cable to connect Siemens SIMATIC S5/PG1
straight to the RS-422-port on the terminals in the
E-series. 3 m.
HMIs
Cables
CAB8
– to connect the terminals in the E-series to PLCsystems via RS-485. Adapter placed on the RS422-port at the terminals.
CAB9
– cable to connect Mitsubishi Fr-A / E inverters
straight to the RS-422-port on the terminals in the
E-series. 3 m.
2 serial ports gives you
freedom
Transparent mode
– Communication with the PLC
system via the terminal, online
No protocol mode
– Communication with external units
Serial Printer
– Communication with a serial printer
HMIs
HMIs
The Communication
”Point to point”, master/slave
– Terminal read/write information.
– PLC replys on requested information.
Signals which effects the communication time
– Overhead signals except signals in the current
block.
– alarms, trends, display-signals,
LED-registers, block-prints, index,
register for PLC-watch etc.
Message
packet
HMIs
The Communication
Signals which NOT effects the
communication time
– Signals connected to function
– keys, time channels,
objects in alarm texts.
Message
packet
Effective communication = (as few message
packets as possible)
–
–
–
–
Group signals.
Don’t dump the watch with to short interval.
Block change with display register.
Packaging of signals (consecutive order).
The future requires new
concepts
New concepts reach new markets new markets gives us new customers
Openness is one key to the future
More effective development work
Even higher quality
HMIs
HMIs
The HMI strategy
Internet technology
More openness
PC-based HMI functionality
Windows CE
More efficient tools
High functionality
Easy handling
Optimized for Mitsubishi Electric products
HMIs
Future customer requirements
* Supervisory connectivity
- Remote HMI/PLC process monitoring/control
- Diagnostics
- Statistic reporting
- Internet connection
- Data file exchange
* Flexible HMI application
- Data exchange with Word, VB, Excel.
- Reuse of objects
- More options for advanced users
* Plant floor connectivity
* OPEN STANDARDS !
- All major PLC:s
- PC-based control systems
- Fieldbuses
- Local networks
- TCP/IP-Ethernet.
- Windows CE/NT/95
- OPC, ActiveX, COM/DCOM
- Internet technology
HMIs
Product hierarchy
SCADA system
CEZAR
Operator terminals
- Graphic
- Text
HMIs
CEZAR concept
Same concept-different platforms
Microsoft®
Windows CE®
Microsoft®
Windows NT®
C-terminals
Adaptions for NT / NT-E / CE
environment
Desktop
Adaptions for NT
environment
HMIs
CEZAR concept
The CEZAR-RT and the CEZAR software will check if
all the necessary components exist on the target
platform. If not, they will be distributed automatically by
the software.
CEZAR
Developing tool
C-Terminal
CEZAR-RT
Any PC
CEZAR-RT
( TCA* )
( TCA )
The Terminal Client Application is
always included in the C-terminals
*The Terminal Client Application
must be purchased separate
HMIs
Basic functions
Alarm handling
Recipe handling
Real-time clock
Time channels
Trend diagrams
Password handling
6
HMIs
Operator interface
Text
Graphic/Pictures
Colours
Touch screen
Print-outs
Possibility to start other
Windows applications
125º
E
710
HMIs
CEZAR developing tool
Three selectable user levels:
Event driven programming
(level 2-3)
Programming with
Visual Basic-script
(level 3)
Drag n’ Drop
ActiveX controls
Copy/Paste from
Windows
3. Enterprise
2. Professional
1. Basic
HMIs
Improved HMI functionality (1)
Data exchange with...
Script language using…
Extended character support
- Unicode
- True Type Fonts
Multimedia support
- Video
- Sound
HMIs
Improved HMI functionality (2)
Internet access
– Web Server - Allow access from other sites
– Web Client - Get data from other sites
Network possibilities
– Distributed objects
– Shared data files (alarm list, application)
– Network with NT-stations
HMIs
Open system
Microsoft technology:
– OPC - allows for 3.rd party drivers
– COM/ActiveX - object component base
– DCOM - distributed objects
Objects based:
– Object accessible from external applications
– Reuse of objects
– Customer can create new objects
HMIs
CEZAR Connections
How many inputs do You have?
USB-Ports
2 x USB
Parallell-Port
Ethernet-Port
TP with RJ45
Serial-Ports
1 x RS422
2 x RS232
Support for
Multiple
drivers
HMIs
Hardware specification NT (1)
Intel/Pentium MMX 266 processor
12.1” Touch TFT display, 800*600, 256 K
colours
C&T 69000, 2MB SDRAM video Chips
64 MB RAM memory, expandable to 128 MB
6.1 GB hard drive , 2.5", EIDE
2 x USB ports
Microsoft
2 x RS-232 ports
Windows NT
RS-422
®
®
HMIs
Hardware specification NT (2)
Parallel port
Ethernet TP 100M, RJ-45 connector
32 bit PCI slot, 2 brackets
2 x 16 bit PC104 slot, stacked
Keyboard, Mouse and sound*
connectors
Microsoft®
Windows NT®
* Optional
HMIs
Future developments
HMIs
Development areas
More E-series drivers will still come
Strengthen low-end area of E-series
EX classified environment
Integration of Internet-technology
Use the benefits from Windows CE and NT
And...
HMIs
The HMI WEB
HMIs
Overview TCP/IP network
Functionality
–
–
–
–
Terminal network, replacing MAC network, 10Mbit/s
Transfer data between PLC-systems
Project transfer
More will come ...
Connection possibilities
– Ethernet Twisted Pair or coaxial
Server
– Serial
New expansion cards
– IFC ETTP, Twisted Pair
– IFC ETCX, Coaxial
Client
BDTP
Server/Client
Overview TCP/IP network twisted pair
HMIs
IFC ETTP in each terminal
Maximum length between terminal and HUB is 100 m
Twisted pair CAT5, shielded or not shielded
RJ45 connector
The number of connections on the HUB settles the
maximum number of terminals
connected to each HUB
No HUB if only two terminals
Overview TCP/IP network coaxial cable
HMIs
IFC ETCX in each terminal
Maximum length on each segment is 185 m
Maximum 30 units on each segment
Maximum 5 segments can be connected via
repeaters and maximum 3 segments can have units
Coaxial cable RG58
Segment
Termination 50 
HMIs
BDTP improvements in version 5
Server Alarms
– - Define the alarm in the
server,
this will be sent to all the
clients automatically when
the signal is activated.
RAS* functionality
– Automatic restart of clients
when server restart.
* Recovery Automatically System
HMIs
TCP/IP - step 2
Intranet / Internet connection
Remote monitoring/Maneuvering
– Via web-sites
– Free Browser
Data transfer
– FTP transfer
E-mail
– SMTP
HMIs
Local connections
Intranet
– Local factory network
– Good response time
– Local domains
Call-up Intranet
– World-wide access
– Good response time
– Local domains
HMIs
Global connection - www
W.W.W.
Internet
–
–
–
–
Published on the WEB.
Uncertain response time.
Global domains.
Mainly for data of public
interest.
HMIs
WEB server
W.W.W.
Standard Web Browser
(Internet Explorer,
Netscape Navigator)
WEB Server
 Each terminal has a
homepage.
 HTML-pages can
contain real-time and
PLC/HMI-data
 HTML-pages are
created on PC and
downloaded to the
terminal
HTML
blablabl
HTML
abbl
blablabl
HTML
abbl
<ssi>
-------l
-----
HMIs
WEB server - remote
Monitoring/Manoeuvring and Control
W.W.W.
HMIs
WEB server - remote
Monitoring/Manoeuvring and Control
W.W.W.
HMIs
HTML codes
W.W.W.
User HTML-pages with
SSI-code
–
–
–
–
–
–
–
Standard Web Browser
(Internet Explorer,
Netscape Navigator)
<-!get_date.fn-!->
<-!get_time.fn-!->
<-!get_diag.fn-!->
<-!get_ipaddr.fn-!->
<-!get_domainname.fn-!->
<-!get_mode.fn-!->
<-!get_device.fn-!->
Function executed when server sees special
codes
HMIs
HTML codes
W.W.W.
User HTML-pages with
CGI-Scripts
–
–
–
–
<-!set_date.fn-!->
<-!get_time.fn-!->
<-!set_mode.fn-!->
<-!set_device.fn-!->
Standard Web Browser
(Internet Explorer,
Netscape Navigator)
HMIs
HTML codes
HMIs
WEB server - remote
Monitoring/Manoeuvring and Control
W.W.W.
Standard Web
Browser
(Internet Explorer,
Netscape
Navigator)
JAVA Applet
View current screen
of terminal
Remote control
terminal by mouse
clicks on PC
HMIs
WEB server - remote
Monitoring/Manoeuvring and Control
W.W.W.
HMIs
FTP server - data transfer
W.W.W.
Standard FTP client
(Included in Internet
Explorer,
Netscape Navigator)
Process data transfer
– Recipes
– log / Trend data
– Alarm list
Application data transfer
– HTML files
FTP Server
HMIs
Transparent mode
W.W.W.
GPP/WIN (2001)
MM+ (April 2001)
Reach PLC
through network
Requires support
from PLC
configuration
software
Tunneling PLCprotocols
HMIs
You have mail...
W.W.W.
Outlook
Express/Netscape.(POP3)
Can redirect mails to f.ex
GSM texts
Standard POP3 Mail server
SMTP
Client
Mail on alarm
Reports through email (textblock)
Forwarding E-mails
HMIs
GOT Product line up
F900GOT
A900GOT
GOT Software
HMIs
F900GOT Range
 F940GOT
– F940GOT-LWD-E
Monochrome
– F940GOT-SWD-E
– 8 colours
 F930GOT-BWD-E
– Monochrome
HMIs
F900GOT functions
Touch screen with IP66F(F940GOT)
Security function
1:n Network
Transparent Mode
Alarm function
Recipe function
Device Monitor
Graphical and Text-Objects
F940GOT replaces and contains all functions
of FX-50DU-TK(S)-E
HMIs
Communication connections
PLC
Connection method
FX1, FX2, FX2C, FX0, FX0S,
FX0N, FX2N,FX2NC
CPU direct connection
Q/A series
CPU direct, PC link
Allen-Bradley PLC
SLC500 series
CPU direct, RS232C
OMRON SYSMAC C series
FUJI N series
PC link
PC board
RS232C
* Connection to Siemens PLC is also planned.
HMIs
F930GOT-BWD-E Dimensions
49 mm
75 mm
146 mm
Display size :
Display colour:
Display device:
Touch switches:
4.4-inch (280 x 80 dots)
2-colour (blue/white)
STN
4 x 15 = 60
(50 positions/screen can be set.)
HMIs
F930GOT benefits
Small and Compact high performance GOT
Dimensional analysis:
– Outer dimensions: 146 x 75mm
– Depth: 49mm (45mm recessed into panel)
High resolution / Industry’s Premiere Resolution
– The 240 x 80-dot screen (15 x 5 lines) provides the
industry’s highest resolution in the small-class display
category.
Long-Life Backlight / Industry’s Longest Lasting
Backlight.
– A full 50,000 hours of operation with a single Backlight.
– This long-life Backlight offers maintenance-free operation.
HMIs
F930GOT benefits
Quick One-Touch Switching
– The FX2N and FX2NC series connected (direct
CPU connection)
– One-touch operations are conducted in 0.16sec
with high-speed response.
Simple Multiple Connectivity (up to 4 GOTs
maximum)
– Using direct CPU connections with the MELSEC
FX or A Series
– A maximum of 4 F930GOTs can be connected to a
sequencer.
HMIs
F930GOT-BWD-E
IP66F Rating
146 x 75 x 49mm- classed as the worlds
smallest control unit.
Easier on the eyes than any comparable
screen on the market.
Easy-to-read wide-angle LCD.
Network expansion a standard feature for up
to four units.
Sampling mode for measurements and
recording.
HMIs
Networking Hardware
Terminal Network with up to 4 stations
possible
Transparent mode
Main control panel
remote‚P
remote‚Q
remote‚R
remote‚S
PLC
RS232C
RS422
15m
30m
RS232C
RS422
30m
15m
HMIs
F940GOT Display properties
Display properties
50°
–
–
–
–
50°
45°
60°
320 x 240 Pixel
STN LCD
8 colours or Monochrome
Excellent view from all
angles
HMIs
F940GOT Dimensions
57
85
22.5
130
22.5(Frame)
Compact size
23.5
162
115
Display
5.7In
23.5
Frame
•5.7in Terminal
with less Dimension
•Water and oil resistent
•IP66F!
HMIs
Comparison of terminals
Category
FX-50DU-TKS F940GOT
Touch keys
32
50
30
50
Display Parameters
mode
Lamps
50
50
Memory
128K
512K
Varieties
50
256
Alarm
mode
History
200
1,000
I/O
2
4
Sampling
Trigger
800
2,000
mode Number
Freq.
2,000
2,000
Dust/Water/Oil
IP65
IP65F
Comparison
x 1.6
x 1.7
Same
x4
x 5.1
x5
x2
x 2.5
Same
+Oil resist.
HMIs
Mitsubishi’s new GOT’s
A900GOT series
A985GOT-TBA-EU
– 256 colours 800x600 Pixel TFT
12”
A975GOT-TBA-B-EU
– 256 colours 640x480 Pixel TFT
10,4“
A970GOT-SBA-B-EU
– 16 colours 640x480 Pixel
STN
10,4“
A960GOT-EBA-EU
– Monochrome 640x400 Pixel EL
8,9“
HMIs
Introducing A900GOT
High speed screen data transfers and OS
transfers.
– also store screen data from a GOT in a memory
card (PCMCIA) and then edit to a PC
List program edit function
– minor modification can be made on site
– compatible with MELSEC-A Series
– command list offers to write, monitor, insert, delete
and parameter edit functions
HMIs
Improved recipe handler
Data 1
Data 2
Data 3
Data
m
m=Max.
8k words
Recipe
data 1
D101
D102
D103
Recipe
data 2
D***
Programmable
controller
n =Max.
256
Recipe
data n
Commercial SRAM card or flash PC
card
HMIs
Bus connection and Recipes
Fast Bus Connections
– use a MELSEC-A/QnA programmable controller for the
fastest bus connection.
– You can achieve similar performance from three GOTs
connected by bus as from a single connected GOT
– high speed response via a bus connection for cyclic
communication
Recipe functions
– data can be stored onto memory cards useable by other
GOTs
Mem.
card
Recipes
HMIs
A900GOT Security
Security functions
– 16 security levels
Password input
A900GOT
Communication speed
1
0.9
0.8
0.7
0.6
HMIs
Bus connection
is fastest
0.5
0.4
0.3
0.2
0.1
0
FX
CC-LINK CC-LINK MNET
transient cyclic transient
MNET
cyclic
UC24
Bus
HMIs
A900GOT dimensions
Extremely slim and compact
Slim line terminal using new Bus or RS422
communication modules
46mm
Size (W x H x D):
297 x 208 x 46 for colour Terminals
268 x 192 x 49 for EL Terminal
HMIs
Connections
A9GT-BUSS
– Bus connection
A9GT-RS4
– Serial connection
PCMCIA card (withQnA series)
– Memory cards for programs and recipe
HMIs
PLC connection
PLC
Connection method
FX1, FX2, FX2C, FX0, FX0S,
FX0N, FX2N, FX2NC
CPU direct communication
Q/A series
CPU direct, PC link, A-Bus and
Networks.
Allen-Bradley PLC SLC500 series
RS232C
OMRON SYSMAC C series
Yasukawa series
PC link
HMIs
GOT Software
GT Works, one Software for all GOT (AGOT
and FGOT) (SWnD5C-GOTRE-E)
FX-DU-SW-WIN-E (Ver.2.30) only for FGOT
DU
FX-DU-WIN-SW-E
F900
GOT
GOT
SW4D5C-GOTRE-SW
Common
HMIs
GT Works
Converter for old projects
Documentation function
Improved help function
Debug function
Project manager
Templates and tool bar
Expanded libraries
Simulation Tools
HMIs
GOT Software
Compatibility A900GOT and A870GOT
GOT800
screen data
Convertor
GOT900
screen
data
Compatibility FX-50DU-TKS and F940GOT
FX-50DU-TKS
FX-DU-WIN-SW
F940GOT
HMIs
Human Machine Interfaces
Questions?