Positioning Statement
LinkRunner
Network Multimeter
An essential personal tool to quickly
verify network connectivity and
availability
1
1
Overview Contents
•
•
•
•
Product selection guide
Feature set overview
Setup and configuration
Product structure
Note – Please run in presentation mode using space
bar to advance slides at your own pace.
2
Product Selection Guide
Function
Link ID
LinkRunner
NetTool
OneTouch
X
X
X
PC Configuration
X
Inline Mode
X
NIC / Hub / Cable Tests
X
X
X
Utilization
X
X
X
X
X
Passive
Only
X
Errors
Device Discovery
Network Statistics
Ping
X
Layer 2
Layer 2-3
Source ID
X
X
Trade Route
X
Duplicate IP Detection
X
Web-Based Operation
X
Reports
3
X
X
X
Cable ID
X
X
Toner
X
X
Traffic Generation
X
Easy to Use
Get Quick Answers to Questions Like These:
• Is this an active Ethernet port?
• What speed/duplex is this device configured for?
• Can I see traffic from this connection?
• Can I Ping?
• Is the PC NIC ok?
• Is this a good cable?
• Where does the cable go?
4
• Isolate performance and
connectivity problems by
verifying that speed and
duplex configurations of the
PC and the switch port are
compatible
• Understand if an Ethernet
port is active by seeing
Utilization
5
Ping
• LinkRunner can be
configured to use DHCP to
automatically acquire a
DHCP address and verify
basic connectivity to key
devices on the network.
6
• LinkRunner will ping the
DNS server and default
router
• Allows you to set up to 4
specified target IP address
• Identify non responsive key
devices by watching
transmitted/received frames
7
• Ping detail shows round trip
time helping you to identify
devices with a slow
response time
• Identifies the segment your
connected to
8
• Quickly isolate the cable
plant or infrastructure as the
culprit of a problem by
checking the cable integrity
9
• Save hours of time
documenting un-marked
segments
10
• Use the optional Cable ID kit
to identify unmarked
segments
11
LinkRunner Setup
12
Configuration
13
Ping Configuration
• In DHCP network
environments, LinkRunner
pings:
– Default Router
– DNS Server
– User-defined device
• If a DHCP address can not
be obtained by LinkRunner,
this symbol will appear.
14
User-defined Device Configuration
15
LinkRunner IP Address
Configuration
16
LinkRunner Subnet Mask
Configuration
17
Blink Hub Port & Send Tone
18
Product Structure
19
LinkRunner
• LinkRunner Kit Contents
– P/N1664475 / LINKRUNNER
– LinkRunner
– Wire map adapter
– Localized users manual (English, French,
German, Spanish, Portuguese, Korean,
Japanese, Chinese)
• LinkRunner Extended Test Kit
– P/N 1778554 / LINKRUNNER-KIT
– All items in standard LinkRunner kit including
all available accessories and custom carrying
case.
• Registration incentive
– Generic belt clip holster
20
20
Models, Options and Accessories
Noun
P/N
Product
Main Product Kits
LINKRUNNER
1664475
LinkRunner
LINKRUNNER-KIT 1778554 Extended Test Kit
21
Accessories
NT-BATT-CHG
1572191
Charger
MT-8200-46
1667985
Toner
BATT-AA-NIMH
1572184
NiMH Batteries
LRUN-WM
1668404
Wiremap Adapter
CLIP SET
1668377
Clip Set
RJ-45 COUPLER 1668361
RJ-45 coupler
LRUN-8001-01
1665935
Cable ID
LR-CASE
1990304
Carrying Case
PC-INSP
1992597
PC Inspector