The First FieldServer in Fiji, the Southern Hemisphere

Download Report

Transcript The First FieldServer in Fiji, the Southern Hemisphere

The First FieldServer in Fiji,
the Southern Hemisphere
Takashi Mishima, Takaharu Kameoka, Atsushi Hashimoto,
Kennichi Nakanishi, Ryoei Ito, Toyokazu Hirozumi, Hiroshi Ehara
(Mie University, Japan)
Takuji Kiura, Tokihiro Fukatsu, Masayuki Hirafuji
(National Agricultural Research Center, Japan)
Marika Tuiwawa, Alivereti Nailatini, Terry Rupeni
(University of the South Pacific, Fiji)
Chitoshi Mizota
(Iwate University, Japan)
Hitoshi Naito
(Kurashiki University of Science And The Arts, Japan)
Background
• We have started the project “Analysis of
Sago Palm Properties in Fiji” at 2002.
• Fiji is the advanced country in the south
pacific area.
• We need ecological information of Sago
Palm habitant.
• Fiji environment is changing because of
economical development.
Where is Fiji?
http://www.aquafiji.com/Fiji%20Geo/Geo.html
Geographical Properties
of Fiji
• Located near the equator and the date line
(S 12°~ 15 °, E 176 °~ W 178 °)
• Southeast part of the Viti Levu Island is
tropical region
(Rainfall is over 3000mm/year at Suva)
• Northwest part of the Island is like savanna
region
(Rainfall is under 2000mm/year at Nadi)
Nadi’s weather data
(Northwest part of Viti
Levu Island)
Suva’s weather data
(Southeast part of Viti
Levu Island)
These data are from World Meteorological
Organization
http://www.worldweather.org/pacific.htm
FieldServer on USP campus
(Lower Campus)
South
West
East
North
Connection topology (I)
FieldServer
Agent Box
(FSAB)
Public
Wired
Network
Access Point
(AP)
MicroPC EES-3412
WZR-RS-G54,
Public
Hightech System
Buffalo
Wired
IP;144.120.26.121
IP;192.168.0.253
Network Local
192.168.0.254
Wired
Network
UPS
External Anntena
(EA)
WLE-DA, Buffalo
Local
Wireless
Network
AC supply
AP
FSAB
UPS
EA
Connection topology (II)
External Anntena
(EA)
WLIE-DA, Buffalo
FieldServer (FS) Ver. 2
Local
Wireless
Network
IP;192.168.0.100 (for PICNIC)
101 (for Access Point)
102 (for Web Camera)
FS
Noted points
• Electric outage
Use UPS for FSAB.
• Network trouble
Use FSAB and store the data on local.
• Pass through to Firewall and/or security system
Use individual IP address and consult with the network manager.
• Traffic throughput
Make new lines (If you are rich).
Let’s go to http://144.120.26.121/
This project was done by using the following Budget and Grant.
Development of data base and model cooperation system
MAFF, Japan
Tropical bioresources grant
JSPS, Japan