MPV 75/150
USER
INTERFACE
AARON CARDENAS
Detailed system information
System Summary
Energy Reports
Configuration
Device Information
Event History
USER INTERFACE Web Interface
WEB INTERFACE
Real-time updates and control
Remote configuration
Easy remote upgrade/backup/restore
No software installation required
Compatible with all major browsers and devices (iOS/Android/Tablets/Phones)
Built-in
2
SUMMARY PAGE Web Interface
SUMMARY PAGE SCREENSHOT
3
Instantaneous Power with Percent Bar (Shows percentage of output compared to capacity) kW
Peak power for the current day (kW)
Energy produced for the current day (kWhr)
Graph behind the power readings highlighting power throughout the current day
Input Voltage and Current
Internal System Temperature (sensed from inside of the controller)
SUMMARY PAGE Web Interface
SUMMARY PAGE
Grid Information
− Voltage/Current/Frequency
Alarm Information
− See manual for the complete list off alarms reported.
Operating Time
Commission Date
Cabinet Serial Number (matches label on the side of the cabinet)
Footer (Visible on all pages)
Alarm Status, Output Power, Operating Time, System Time, Model #, Serial #
4
REPORTS PAGE Web Interface
REPORTS PAGE SCREENSHOT
5
Day Graph
Table showing the energy (kWhr) produced each hour of the day
Line Graph shows the power thoughout the day.
May select different days of data to view.
Updated in real-time while viewing the page.
REPORTS PAGE Web Interface
REPORTS PAGE
Month Graph
Table in calendar format shows energy produced each day of the month.
Bar Graph shows energy for each day of the month for easy comparison.
May select different months of data to view.
Year Graph
Table shows energy produced each month of the year.
Bar Graph shows energy for each month of the year for easy comparison.
May select different years of data to view.
6
DEVICES PAGE Web Interface
DEVICES PAGE SCREENSHOT 1
7
DEVICES PAGE Web Interface
DEVICES PAGE SCREENSHOT 2
8
Controller Info
Output Power, Status, Serial, FW Version
Inverter Info
Module output power, State (On, Off, Standby, Alarm), Status, Output
Voltage/Current/Frequency, Input Voltage/Current, Temperature, Operating Time, Model,
Serial, Vendor Code, FW versions.
DEVICES PAGE Web Interface
DEVICES PAGE
Module background changes color depending on module state.
Distribution Info
•
Analog Inputs (Input Voltage/Current)
•
Discrete Inputs (Door, GFI, AC/DC Switches, Surge Protection Devices)
•
Relay Outputs (Input Contactors, GFI Control)
•
If the state graphic is filled in, that indicates that the particular input/output is active/connected
•
Inputs/Outputs can be labeled on the configuration page.
9
DEVICES PAGE (List View) Web Interface
DEVICES PAGE (List View) SCREENSHOT
10
Tabular view of inverter parameters
ID – Shelf slot location
Output Power/Voltage/Current/Frequency
Temperatures
Sortable
Updated in real-time
DEVICES PAGE (List View) Web Interface
DEVICES PAGE (List View)
Easy comparison of each inverter module
11
CONFIGURATION PAGE Web Interface
CONFIGURATION PAGE SCREENSHOT
12
System Configuration
Name, Description, Address, Commission Date, Date/Time, Temperature Units, GFI Control,
Startup/Shutdown Control, LED Test.
Login button is at the top right of the page.
Notifications
Configure which e-mail address will receive alarms, event, and performance reports.
− Note: This feature requires an e-mail server to be configured on the network page.
CONFIGURATION PAGE Web Interface
CONFIGURATION PAGE
Inverters
Anti-Islanding configuration.
− WARNING: The default values on this configuration screen are set to meet the requirements of UL 1741
and IEEE 1547. Contact technical support before changing any of these values.
Input/Output
Distribution input/output information.
− Name, Polarity, Alarm, Feedback, Pulse Time.
13
Network
IP Configuration
Web Server Port
E-mail server
User Account
Web password
Administrator e-mail address
Local Access (Display) PIN number.
Backup/Restore
CONFIGURATION PAGE (continued) Web Interface
CONFIGURATION PAGE (continued)
Upload: Controller FW, Inverter FW, Distribution FW, Display FW, Configuration
− Conveniently upgrade system FW and configuration through one interface.
Backup Configuration/Data Logs
Reset to factory defaults
14
EVENTS PAGE Web Interface
EVENTS PAGE SCREENSHOT
15
1000 events stored
Color coded
Sortable
Searchable
CONFIGURATION PAGE Web Interface
EVENTS PAGE
*See Table 6-2 System Faults in the manual for more information on events that are stored.
16
Main Screen
Output Power Gauge
Graphical representation of system state
and configuration
−
−
−
−
Blank
Solid
Dotted
Cross
= Slot Empty
= Standby
= On
= Alarm
USER INTERFACE Local Display
LOCAL INTERFACE
Day/Month/Year Energy Graphs
Alarms
Menu System
Detailed view of system parameters and
device parameters
Alarm Reporting
17
Main Screen
Date/Time, Input Voltage, Output Voltage/Current, Output Power Percent Bar
Day, Month, Year Bar Graph
Alarm Display
Cabinet Display with animated icons
−
−
−
−
Blank
Solid
Dotted
Cross
USER INTERFACE Local Display
MENU TREE
= Slot Empty
= Standby
= On
= Alarm
Main Menu
Alarms
Data
− Array
Power, Current, Voltage, DC Switch Status, Contactor Positive/Negative Status
− Cabinet
Number of inverters, Operating Hours, Remote Shutdown State
18
Main Menu
Data
− Inverter
Summary with power output
– State, Status, Output Power, Energy Today, Capacity, Temperatures, Input Voltage/Current
− Grid
USER INTERFACE Local Display
MENU TREE (continued)
Power, Energy Today, Voltage/Current (Phase ABC), Frequency, AC Switch Status
− Clock
Date/Time, Day of Week
− Network
IP Address Summary
– Link status, State
Configuration
− System
Location, Commission Date, Cabinet Serial, Model, Temperature Units, Hardware Revision, Mail
Server/Port/Username, HTTP Port.
19
Main Menu
Configuration
− Display
FW Version Application/Bootloader
− Inverter
Model, Serial, Vendor, FW Versions, Manufacturing Date
− Clock
USER INTERFACE Local Display
MENU TREE (continued)
Date Format, Time Format, SNTP Server, Time Zone, Daylight Savings, DS Start/End,
− Network
Type, IP, Gateway, Mask, DNS, MAC
Actions
−
−
−
−
Login (Default PIN: 1234)
Reset GFI
System Control (Start/Shutdown)
Change Display PIN
Display Settings
− Beep, Inverter Colors, Language, Demo Mode
20
Aggregated view of multiple cabinets from one interface
Weather station information display
3rd party monitoring support
FUTURE DEVELOPMENT
Future Development
Improvements to the reports page
Graph annotations (mouse-over information)
New information (i.e. Temperature plots)
Custom comparisons (Compare different days, month, years)
21