Transcript 幻灯片 1
Multiple Network Cables: Corrosive at Dangerous areas, Difficult to Be Routed,
and High Costs in Remote Areas
Network equipment room
Network cables are eroded because of high
temperature and wasted gas.
Cables are eroded. The monitoring channels are
blocked. As a result, the monitoring is unavailable.
In dangerous areas, cables are unreachable. As a
Monitoring center
• Cables are eroded.
The monitoring channels
are blocked.
Hundreds of
network cables
result, it is difficult to monitor the environment.
In high-temperature and poisonous areas, cables
cannot be deployed. As a result, it is difficult to monitor
the environment.
Cable routing costs are high at remote areas.
In remote areas, cables must be several kilometers
long. These cables are difficult to be routed and the
engineering costs are high.
Waste gas detection
• In high-temperature and
poisonous areas, cables
cannot be deployed.
Dangerous area
Remote area
• Cables must be several
kilometers long, and the
cable routing costs are high.
LTE Internet of Things for Manufacturing Environment Monitoring: Real-time
Environment Monitoring Without Using Cables
Gateway of
the Internet
of Things
Collection
layer
Transport layer
CPE
DBS3900
RS232
The coverage radius of a single
eNodeB is 30 km, ensuring
seamless coverage of remote
monitoring points and
dangerous environment.
An eNodeB supports a
maximum of 5400 concurrent
service requests.
Dedicated frequency 1.8 GHz is
used, which has strong
interference resistance
capability.
Rich terminal deployment
modes increase the ROI. The
deployment modes include
RTU+CPE or the Mini PCIe
embedded with the RTU.
Intelligent
analysis
Equipment
room
Mini PCIe
+
Pollutant
discharge area
Waste gas
detection
Environment
Power
Remote
monitoring consumption decision
monitoring
RTU
Polluted water
detection
Monitoring center
30 km
RS232
Solution characteristics
Application layer
eCNS600
Data Center
RS232
Coal gas
detection
CPE
RTU
Energy medium
management area
DBS3900
Environment
monitoring system
Energy management
system
Multiple Dangerous Areas and Equipment Materials; Difficult to Position
Personnel Location, Monitor and Manage Equipment
There are a lot of dangerous areas. When a
person enters a dangerous area mistakenly,
warnings cannot be sent to the person.
Dangerous areas have characteristics such as high
temperature, high pressure, and proneness to combustion
and explosion.
If a person enters a highly hazardous area mistakenly,
warnings cannot be sent to the person, which results in
casualties and deaths.
A large number of materials require manual
scanning when they are in or out of the
warehouse. The workload is heavy.
Dangerous areas
Spare parts
warehouse
Persons enter dangerous areas
mistakenly, and no warning is sent.
Move spare parts
out the warehouse.
• More than
2000 kinds of
spare parts
and the spare
parts needs to
be scanned
manually. The
workload is
heavy.
More than 2000 materials need to be scanned manually for
thousands of times every day. The workload is heavy.
Assembly
workshop
Parts reach the
destination.
Spare parts
transportation
Material and Personnel Positioning and Real-time Information Push Using Wi-Fi
Production
equipment room
Production factory
Spare parts
warehouse
Production
monitoring center
Providing location-based
services: navigation,
information push, and
alarm association
RTLS
Solution characteristics
•
Wi-Fi-based positioning and specific
information push
UE, tag, or RFID wireless signals are
collected by the AP and aggregated by
the AC. The RTLS calculates the
longitude and latitude (with a precision
of 3 to 5 m) and sends the information
to the production monitoring center to
provide the following functions:
Route guidance
Material tracing
Campus navigation
Sending warning notifications in
dangerous areas
Real-time specific information push
AP
Wi-Fi signal
Assembling
area
Application
server
RFID signal
read and write
information push
platform
Providing location
monitoring, information
push, and warning
notifications in dangerous
areas
AP
AC
Location information
collection flow
Location service
pushing flow
Location information, such as whether spare parts
reach the destination.
Information push
enabling or disabling flow
Wi-Fi-based positioning + specific information push flow
Invisible Cluster Dispatch; Site Conditions Fail to Pass Back Promptly
“Please help me locate
whether the cable connection
is correct: Left or right……..
?
Invisible cluster dispatch(for
traditional Clusters )
Site phonetic description
Customers Pains
Remote expert
It is difficult for site complex
conditions to describle clearly
Site Conditions
with phonetic
“Please let us know the situation”
Site Conditions fail to pass back
Waiting……
promptly(for operator networks)
“What……”
(Voice prompts )“This call has ended!”
Site engineer
Dispatch center
Time delay is too long. Communication interrupts.
Time delay is too long,
communication is rather timeconsuming,even
communication interrupt
Command and Dispatch During Production-Intelligent
Multimedia Cluster Communication
Highlights and
Deployment
Factory area
Handheld cluster
communication
terminal
Handheld cluster
communication
terminal
Video monitoring
server
DBS3900
dispatch
Real-time Multimedia Transmission
Network
equipment
room
Cluster server
eCNS600
Vehicle-mounted terminal
Professional voice cluster
Dispatch terminal
Handheld cluster
communication terminal
DBS3900
Alarming for Staff Member Falldown
Terminal drops
to the ground.
Staff member falls down.
Dispatching center
Remote Activation and
Deactivation
Professional cluster
communication, multiparty intercom, and
command and dispatch at
emergencies.
Sharing of multimedia data
such as photos and video
streams which enables
users to visually know site
conditions(traditional
cluster communication
supports only voice
services).
Deployment of LTE
networks in the factory
area,deployment of video
monitoring server and
cluster server in the
dispatching center;
implementation of the
eLTE cluster
communication function in
dispatch terminal.
Factory Wireless Network Solution: Wide LTE Coverage and Wi-Fi
Coverage for Hot Spots
Solution features
Production area
Network
HQ
Logistics
Environment
monitoring
and energy
medium
Data Center
DBS3900
Campus
network
eCNS600
Material
and
warehouse
monitoring
Outdoor
AP
Indoor
AP
Fixed inspection
of equipment&
warehouse
Remote equipment Personnel
shelves
fault diagnosis
positioning
offices
BYOD
……
LTE: Used for remote video monitoring,
multimedia cluster, mobile scheduling,
and manufacturing environment
monitoring.
Wi-Fi: Used for mobile office, personnel
positioning, and information push.
Outdoor APs access the network using
the LTE.
Wide network coverage: The coverage
radius of the LTE reaches 100 km.
High bandwidth: The peak rate is 100
Mbit/s in the downlink and 50 Mbit/s in
the uplink. The throughput is greater
than 60 Mbit/s in high speed scenarios.
Easy to be deployed: Small-size EPC
eCNS600 and distributed base station
DBS3900 are small in size and light in
weight, and therefore easy to be
deployed.