Resting 12-Lead ECG

Download Report

Transcript Resting 12-Lead ECG

Hillmed
HM-Cardio MD

PC Based Resting 12-Lead ECG

Notebook Based Resting 12-Lead

PDA / Smart Phone Resting 12-Lead

Ambulance to ER Resting 12-Lead

Multi-Hour 12-Lead Monitoring

Blue Tooth Transmitter @ 100 Meters

Includes Simple Stress Test Program

4.0 Standard or Premier Programs

Optional 5.0 Stress Test Program

Interpretation / Suggestion

Serial Comparison

SAECG Late Potentials

Vectorcardiography

Hi-Frequency 12-Lead Analysis

QT, QTc, and QTd Analysis

Axis Deviation

FrequencyCardioGram

Page-Scan Full-Disclosure Review

Standard ECG

Quick ECG

Multi-Hour ECG Monitoring

Simple Stress Test






ECG Acquisition for a few seconds.
ECG, Time, and Heart Rate are
displayed.
Upon display of clean ECG, perform a
mouse click.
ECG is immediately analyzed for
interval measurements.
Upon verification of correct intervals,
perform a mouse click
12-Lead test is completed.




The 4.0 Standard program includes
the 12-Lead ECG program, plus the
Interpretation program.
The Interpretation program includes
the Axis Deviation analysis.
The quick visual edit of the vertical
marker locations for:
* Beginning of P-wave
* End of P-wave
* Beginning of Q
* End of S
* Beginning of T
* End of T
provides the correct foundation for
the Interpretation program.
HL7 and Dicom outputs available.



The 4.0 Premier program includes:
* 12-Lead ECG
* Interpretation
* Simple Stress Test
* SAECG Late Potentials
* QTc & QTd
* FrequencyCardioGram (FCG)
* Multi-Hour ECG with HRV
* Hi-Frequency ECG
* VectorCardioGraphy (VCG)
ECG Acquisition is with:
* Blue Tooth Transmitter (100 meters)
* USB Hi-Res Acquisition Box
* HM-Holter MINI-Recorder
A low-cost and simple Holter CS-6A
program is an optional add-on to the
Winnervision program.





Blue Tooth sends 12-Lead ECG to
PDA or Smart Phone (PSP), with the
Resting 12- Lead software.
PSP displays, analyzes, stores, and has
printer outputs for the 12-Lead.
ECGs can be collected for a large
number of patients, and then
transferred to the 12-Lead PC station
in the hospital’s EKG Lab.
12-Lead ECG strips can be e-mailed to
PCs or other physicians. This makes
for a pocket ECG system that the
physician can take into any out-of-theoffice environment.
Ideal for sports medicine and
Ambulance monitoring environments.






Ambulance to hospital ECG for
immediate treatment of cardiac
patient emergencies.
Blue Tooth ECG to Smart Phone.
Smart Phone transmits 12-Lead ECG
on demand or at pre-set intervals.
Ambulance personnel receive
verification for life-saving
interventions.
Upon arrival at hospital, 100% of
Ambulance 12-Lead ECG is
transferred to CS-12 for review in
real-time mode and Holter mode.
ECG continues in Emergency Room.









12-Lead Hospital Patient
Monitoring with Blue Tooth.
Single patient ECG station.
Analysis of:
Arrhythmias
ST
QTc and QTd
Heart Rate Variability
Patient can be mobile with
Blue Tooth Transmitter.
Sample rate of 4,096 with
12-Bit resolution.





Included in 4.0 Premier.
Displays:
Heart Rate
Target Heart Rate
% of Target Heart Rate
Delta Heart Rate Change
Elapsed Time
The reference beginning
ECG is shown at the far left
side for each ECG Lead.
ECG prints available at all
times during Stress Test.
Stress Test reviewed in Page
Scan mode.





Resting 12-Lead security key is also
programmed with the simple CS-6a
Holter program.
For the non-cardiologist market.
CS-6a consists of a 24-hour miniHolter recorder (300-4) and a Holter
software program.
The 300-4 can be a 3-Lead or 12Lead recording for 24-hours.
CS-6a is a Page-Scan and Full
Disclosure program. There is no
Template editing, but the program
includes the Category Event
displays of ECG abnormalities that
can be edited,
SAECG Late Potentials

HM-CARDIO MD program includes:
SAECG Late Potentials
Vectorcardiography
Hi-Frequency ECG
QTc
SAECG

SAECG program allows for manual edit.
VectorCardioGraphy

VCG
Vectorcardiography also includes the Timed
VCG which allows the VCG Loops to be directly
compared with the XYZ ECG.




FrequencyCArdioGram
The FCG CADgram
detects and locates
blockages in the
coronary arteries.
It does not require any
exercise protocol. The
Resting 12-Lead is the
preferred environment
for the FCG test.
A positive FCG
CADgram is a strong
indication for an
exercise stress test.
High Resolution QRS ECG


Hi-Frequency ECG
The Hi-Frequency ECG is to closely examine the
notches and slurs of the expanded QRS.
Mini ECG Card for Patient Wallet or Purse


Mini ECG Pocket Card
The program produces a ECG patient
information card that can be carried in the
patient’s wallet or purse.
Holter Full Disclosure
Sixteen (16) Ventricular Ectopic ECG’s

Uses 300-4 device.

For the non-cardiologist market.


Instant E-Mail of Holter Report Pages
This is a Page-Scan and Full Disclosure Holter
ECG system with ECG print-outs.
The Category ECG Events of Pause, ST, VE, VRuns, SVE, Min. HR, Max. HR, etc. are displayed
for ECG acceptance or rejection.

PDF e-mailing of ECG data is included.

Database storage and retrieval is included.
Blue-tooth ECG transmitter and receiver
HM-CARDIO MD BLUE TOOTH

Method of transmitting and receiving: Digital;

Transmitting and receiving frequency: 2.4G Hz;

Working distance: Model: 15m visible;

Transmitter voltage: DC 6.0V;

Receiver voltage: DC 5.0V.
Blue-tooth ECG transmitter and receiver















Sample rate: <=4096Hz;
Sample resolution: 12bit;
Lead: 12-lead standard ECG;
Input circuit current: ≤0.1μA;
Input impedance: ≥5 MΩ;
Noise electric level: ≤15μVp-p;
Standard sensitivity: 10mm/mV ±5%;
Anti-polarization voltage: if add ±300mV DC polarization
voltage, the change of sensitivity is not more than ±5%;
CMRR: ≥60 dB;
Frequency response: 0.5 -150 Hz(+0.4 dB, -3.0 dB);
Lower frequency feature: time constant is not less than
3.2s;
Stability: when the power supply transient change is 10%,
the baseline wondering is not more than ±5%. The
sensitivity error is not more than ±5%.50Hz filter: ≥20dB;
Equipment safety type: the wired ECG acquisition box is
class II, type-BF; the blue-tooth ECG transmitter is type-BF
with internal power; the blue-tooth ECG receiver is class II,
type-B;
Working environment: Temperature: 10 - 30℃, Relative
humidity: ≤70%, Atmospheric pressure: 860 - 1060hPa;
Storage environment: Temperature: -20 - 55℃, Relative
humidity: ≤93%, Atmospheric pressure: 500 - 1060hPa.
Bluetooth Transmitter (front)
Bluetooth Transmitter (back)
Bluetooth Receiver
Patient Cables
1. Connect the Bluetooth receiver to the USB port
of the computer.
2. Connect the patient cable to the Bluetooth
transmitter.
3. Insert the batteries into the Bluetooth
transmitter.
4. Hold the power switch at the top of the
Bluetooth transmitter for 3 seconds. The LED
lights on the front will light up to indicate it is
on and active.