No Slide Title

Download Report

Transcript No Slide Title

Click here for
Final Jeopardy
Structural
Fumigation
Safety
EPA
Rule Changes
IPM’s for
Rodents
FMP’s for
Rodents
1 Point
1 Point
1 Point
1 Point
1 Point
2 Points
2 Points
2 Points
2 Points
2 Points
3 Points
3 Points
3 Points
3 Points
3 Points
4 Points
4 Points
4 Points
4 Points
4 Points
5 Points
5 Points
5 Points
5 Points
5 Points
Aluminum Phosphide must be
transported to the jobsite in an
approved container.
(True or False)
True
Zinc Phosphide is a
Restricted use Fumigant
and requires a License to
purchase.
(True or False)
False
Monitoring these readings are
required when using
Aluminum Phosphide.
What is
Fumigant Concentration
Readings?
The lowest grain
temperature allowed when
using aluminum phosphide
is.
41 Degrees Fahrenheit
The formula for finding the
volume of a cylinder.
3.14 x radius squared x height
Name of the area around rodent
fumigant application which
bystanders and pedestrians
must be kept out
What is the Buffer Zone?
The fumigant gas which
smells like garlic.
What is phosphine?
An applicator, to qualify for
wearing respiratory
equipment does
What are fit test, equipment
training, and determined to be
physically fit to wear respirator?
You need to wear this is
concentrations of aluminum
phosphide exceed 15 ppm.
SCBA
5 of the symptoms of exposure
to a fumigant
What are:
Slowed body movements
 Slurred/slowed speech
 Dizziness
 Numbness of hand or feet
 Coughing
 Sneezing
 Nausea
 Abdominal pain
 Stimulate drunkenness?
Applications of aluminum
phosphide strictly prohibited
What are single and multifamily residential properties,
nursing homes, schools, day
care centers, hospitals?
The lower flammable limit of
a/p.
What is 18,000 ppm?
The Short-term exposure
limit (STEL) for a/p.
What is 1 ppm?
Minimum distance from a
building where applications of
a/p may be made.
What is 100 ft?
The maximum application rate
for burrowing rodents
What is 10-20 pellets?
Cultural practices that
can affect rodent
numbers
What are – soil
tillage/cultivation, crop
rotation, irrigation, burning,
grazing mgmt?
Two types of fumigant
used to control rodents
What are – ignitable gas
cartridges and aluminum
phosphide?
Prebaiting is necessary for
which rodenticide bait
What is – Zinc Phosphide
The number of applications
and time between applications
required for Rozol rodenticide
baits
What is - 2 applications 2 – 3
days apart?
Additional information on
aluminum and magnesium
phosphide can be found at this
site
What is the EPA website?
epa.gov/oppsrrd1/reregistration/alphosphide/
When should a Rodent Fumigation
Management
Plan (FMP) be completed?
What is - Prior to fumigant
application.
Is 15-100 ft an acceptable
distance from buildings that
humans or domestic animals
inhabit that Aluminum
Phosphide can be applied
(True or False)
False
A commercial applicator
applying aluminum
phosphide fumigant must
provide a copy of the
completed FMP to
Who is – the customer?
Information required on a
placards which should be
placed at all fumigation sites
What are – the signal word
DANGER/PELIGRO, skull and
crossbones, name and EPA
registration number of the fumigant,
and a 24 hour Emergency Response
number?
Timeframe before application
for applicators to provide
information directly to
neighbors?
What is 48 hours?
Make your wager
7 Difficult to Evacuate Sites
What are:
-Schools (Pre-K - 12)
-State licensed daycare centers
-Nursing homes
-Assisted living facilities
-Hospitals
-In-patient clinics
-Prisons?