Short Version : 24. Electric Current
Download
Report
Transcript Short Version : 24. Electric Current
Short Version :
24. Electric Current
24.1. Electric Current
Current (I) = Net rate of (+) charge crossing an area.
Biomedics: I ~ A
Electronics: I ~ mA
Steady current:
[ I ] = Ampere
I
Q
t
Instantaneous current:
+ charges moving right
dQ
dt
Zero net
current
Net
current
charges moving left
I
Both charges moving right
Curent: A Microscopic Look
v of charge carriers in media with E = 0 is
thermal ( random with v = 0 ).
For E 0, vd = v 0.
Charge in this volume is Q = n A L q.
I
n ALq
Q
L / vd
t
drift velocity
n = number of carriers per unit volume
q = charge on each carrier
I n A q vd
Example 24.1. Copper Wire
A 5.0-A current flows in a copper wire with cross-sectional area 1.0 mm2,
carried by electrons with number density n = 1.11029 m3.
Find the electron’s drift speed.
vd
I
n Aq
5.0 A
1.11029 m3 1.0 106 m2 1.6 1019 C
2.8 104 m / s
0.28 mm / s
TIP: Big difference between vd ~ mm/s and signal speed ~ c.
Current Density
Current can flow in ill-defined paths ( vd depends on position ),
e.g., in Earth, chemical solutions, ionized gas, …
Better description of such flows is by
current density ( J ) = current per unit area
J n q vd
vd
[ J ] = A /m2
Charge density
Example 24.2. Cell Membrane
Ion channels are narrow pores that allow ions to pass through cell membranes.
A particular channel has a circular cross section 0.15 nm in radius;
it opens for 1 ms and passes 1.1104 singly ionized potassium ions.
Find both the current & the current density in the channel.
1.1104 1.6 1019 C
Q
I
t
1103 s
1.8 1012 A
~0.3 nm
Lipid molecules
ion channels
AWG 10 :
J
30 A
5.7 MA / m2
2
5.26 mm
I
J
A
1.8 pA
1.8 1012 A
0.15 109 m
25 106 A / m2
2
25 MA / m2
~ 4 times max. safe current
density in household wirings
24.2. Conduction Mechanism
E 0 in conductor
Collisions
J E
non-electrostatic equilibrium
charges accelerated
steady state
conductivity
Ohmic material: independent of E
J
1
E
resistivity
[] Vm/A m
[] (m)1
Ohm’s law,
microscopic version
Material
Resistivity (m)
No band gap
Metallic conductors (20C)
Aluminum
2.65108
Copper
1.68108
Gold
2.24108
Iron
9.71108
Mercury
9.84107
Silver
1.59108
Ionic solutions ( in water, 18C)
1-molar CuSO4
3.9104
1-molar HCl
1.7102
1-molar NaCl
1.4104
H2 O
2.6105
Blood, human
0.70
Seawater (typical)
0.22
Semiconductors (pure, 20C)
Small band gap
Germanium
0.47
Silicon
23.0
Insulators
Large band gap
Ceramics
1011
1014
Glass
1010 1014
Polystyrene
1015 1017
Rubber
1013 1016
Wood (dry)
108 1014
Example 24.3. Household Wiring
A 1.8-mm-diameter copper wires carries 15 A to a household appliance.
Find E in the wire.
E J
I
A
15 A 1.68 108 m
0.90 10 m
3
2
99 mV / m
Conduction in Metals
Metal: ~ 108 106 m
Atomic structure: polycrystalline.
Carriers: sea of “free” electrons, v ~ 106 m/s
E = 0: equal # of e moving directions v = 0.
E 0: Collisions between e-ph vd ~ const.
dv m
v eE
dt
dv
0
Steady state:
dt
= relaxation time
m
vd
ne2
J n e vd
E E
m
T
Cu
eE
m
Ohm’s law
Due to high T Bose statistics of phonons.
c.f., vth T
Ionic Solutions
Electrolyte: Carriers = e + ions
~ 104 105 m
Examples:
Ions through cell membranes.
Electric eels.
Batteries & fuel cells.
Electroplating.
Hydrolysis.
Corrosion of metal.
Plasmas
Plasma: Ionized gas with e & ions as carriers.
Examples:
Fluorescent lamps.
Plasma displays.
Neon signs.
Ionosphere.
Flames.
Lightning.
Stars.
Rarefied plasma (collisionless) can sustain large I with minimal E.
E.g., solar corona.
Thermal motion
dislodges an e ...
Semiconductor
Pure semiC:
T = 0, no mobile charge carriers.
T 0, thermally excited carriers, e & holes.
increases with T
… leaving a hole
behind.
e & h move
oppositely in E
Doped semiC:
Mobile charge carriers from impurities.
N-type: carriers = e. Impurities = Donors. E.g. P in Si.
P-type: carriers = h. Impurities = Acceptors. E.g. B in Si.
Phosphorous
with 5 e
Bound e jumps left,
h moved to right
P fits into Si lattice, leaving 1 free e
PN Junction
Current flows in only 1 direction
Depletion
region
No battery:
e & h diffuse across junction &
recombine.
Junction depleted of carriers.
Reverse bias:
e & h pulled away from junction.
Depletion region widens.
I ~ 0.
Forward bias:
e & h drawn to junction.
Depletion region vanishes.
I 0.
Application: Transistor
Large current change controlled by small signal (at gate):
Amplifier, or
Digital switch.
Normally channel is closed
( I = 0 ) as one of the
junctions is reverse biased.
+ V applied to gate attracts e to
channel: I 0
Superconductor
Onnes (1911): Hg = 0 below 4.2K.
Muller et al (1986): TC ~ 100K.
Current record: TC ~ 160K.
TC =
Applications:
Electromagnets for strong B:
Labs, MRI, LHC, trains …
SQUIDS for measuring weak B.
YBaCuO
24.3. Resistance & Ohm’s Law
Ohm’s Law
I
V
R
macrscopic version
Open circuit:
R
I=0
Short circuit:
R=0
I V
J
E
V
I JA
R
E
A
V
A
L
L
A
Resistor: piece of conductor made to have specific resistance.
All heating elements are resistors.
So are incandescent lightbulbs.
Table 24.2. Micrscopic & Macroscopic Quantities in
Ohm’s Law
Microscopic
Macroscopic
Relation
E
V
V E dr
EL
J
I
I J dA
J A
R
J
1
E
I
R
V
R
L
A
24.4. Electric Power
Electric Power :
P
d
q V
dt
IV
V2
PIV I R
R
V I R
2
Power increase with R
( for fixed I )
for time independent V
Power decrease with R
( for fixed V )
No contradiction
Conceptual Example 24.1. Electric Power Transmission
Long distance power transmission lines operate at very high voltages – often
hundreds of kVs.
Why?
Power
P = I V.
Transmission loss
PW = I 2 RW = P2 RW / V2
Low I , i.e., high V , lowers PW for same P.
PW = (V VL )2 / RW
= (V P RL / V )2 / RW
VL < V because of power loss in wire
see Prob 56
Making the Connection
What is the current in a typical 120 V, 100 W lightbulb?
What’s the bulb’s resistance?
I
P 100 W
V
120 V
R
V
I
120 V
0.833 A
0.833 A
144
24.5. Electrical Safety
TABLE 24.3. Effects of Externally Applied Current on Humans
Current Range
Effect
-------------------------------------------------------------------------------------------------0.5
2 mA
Threshold of sensation
10 15 mA
Involuntary muscle contractions; can’t let go
15 100 mA
Severe shock; muscle control lost; breathing difficult
100 200 mA
> 200 mA
Fibrillation of heart; death within minutes
Cardiac arrest; breathing stops; severe burns
Typical human resistance ~ 105 .
Fatal current ~ 100 mA = 0.1 A.
V 0.1A 105 10,000V
A wet person can be electrocuted by 120V.
Large current
thru operator
No current
thru operator
Large current
blows fuse