Transcript Slide 1

Threshold Shift vs Gate Oxide Thickness
Poly- Si
Gate
e--
SiO2
++
++
++
++
++
++
+
+
+
+
+
+
Si
+
+
+
+
+
+
e-
Tunneling Region
Hole removal process by tunneling in
thin-oxide MOS Structures
Dosage = 150 Krads
Sachs et. al. IEEE Trans. Nuclear Science NS-31, 1249 (1984)
Book. Timothy R Oldham “Ionizing Radiation Effects in MOS Oxides” 1999 World Scientific
1
Company
Oxide
Thickness
nm
Device
IHP
A
XYSemi
XYSemi
Dose before
Damage seen
Observation
Damage Mode
ASIC custom
5
53 Mrad
slight damage
FET 2 amps
7
52 Mrad
Minimal damage
XP5062
12.3
Loss of output
voltage regulation
44 krad
TI
TPS54620
20
23 krad
abrupt failure
Intersil
ISL 8502
unknown
40.6 krad
Increasing
input current
IR
IR3822
unknown
139 krads
Increasing
input current
IR
IR3841
9 & 25
13 krads
Loss of output
voltage regulation
ST
ST1510
unknown
125 krad
Loss of output
voltage regulation
Enpirion
EN5365
5
85 krad
Increasing
input current,
Enpirion
EN5382
5
111 krads
Loss of output
voltage regulation
Enpirion
EN5360 #2
5
100 Mrads
Minimal damage
Enpirion
EN5360 #3
5
48 Mrads
Minimal damage
2
Buck Regulator Efficiency after 100 Mrad dosage
80
Power Efficiency %
75
After
Exposure
70
65
Before
Exposure
60
55
Enpirion EN5360
With Integrated Inductor
50
45
40
0
1
2
3
4
5
6
Output Current Amps
Found out at Power Technology conference 0.25 µm Lithography
 Irradiated
Stopped on St. Valentines Day 2007
 We reported @ TWEPP 2008 - IHP was foundry for EN5360
3
Twepp Nagos
4
XYSemi XP2201#1
Efficiency(%)
72
71
XYSemi XP2201#1
70
69
0
10
20
30
40
Dose(krad)
LM2864
Efficiency(%)
80
78
76
74
LM2864
72
70
0
1000
2000
3000
4000
Dose(krad)
5
6
Is there a Commercial product available ?
Yes = It is the EN5360
 Satellite folks are using it now
 sLHC Levels – 100 Mrads
 Use for voltage ratio = 4
 Work at Super LHC levels for Tracker
 5.5 V in > 1.3 out
 Enpirion is still supplying these to a very large customer
 IHP foundry will make it for many years.
 Can purchase in Die form for use with Air coil
For Purchasing EN5360:
Steve Robb (908) 894 -6083 [email protected]
Tom Howell (908) 894-6029 [email protected]
7
DC-DC Converter Voltage ratio = 8/10
Load: Rated Current or maximum without cooling ~ 1 amp
Setup for 4 EVAL Boards
Measure Bias Current with Load disconnected
Power Supply
V out > 5 – 20 Volts
4 Wire Current shunt
~ 0.5 Amps
.
VInput
GND
5.5 V max to prevent
damage.
V Output Monitor 2 wire Differential
Twisted Pair Preferred
V Input Monitor. 2 Wire Differential
Agilent 34970A &
Multiplexer 33901A
to Monitor I & V
Buck Regulator Eval Board
Size = 3 inch x 3.5 inch
Twisted Pair Preferred
Solder all wires ????
V Output Monitor 2 wire Differential
4 Wire Current shunt
1 to 5 Amps
.
GND
V Output = 1.5 V
.
V Output Monitor 2 wire Differential
Load Resistor
= 0.3 to 1.5 Ώ
Switch on/off
Line Drop ~ 0.25 volts @ 6 amps in each Leg ???
Banana Jacks / Solder Wires
Satish Dhawan, Yale University
April 21. 2008
DC-DC Regulator Setup for Radiation Exposure
8