Transcript Iron Filter
Common Water Treatment Problems
Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up.
Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related Iron. Stains Red
Manganese -Similar concerns as Iron, but usually stains Black.
Total Dissolved Solids (TDS) -Indicates the total amount of dissolved minerals
in the water. This would include the Hardness, Iron and Sodium, but not
Bacteria or H2S.
Bacteria -Microorganisms that multiply and feed from the elements in water.
Can be very harmful, such as Fecal Coliform, or only an aesthetic concern like
Iron Bacteria.
Arsenic -Now considered one of the poisonous elements in water. Must remove
at very low amounts (0.01 mg/l).
Tannins -Decaying vegetation in water. Gives water a tea colour.
Hydrogen Sulfide (H2S) -In a gas form, and gives a Rotten Egg smell to the
water. Will normally dissipate when exposed to atmosphere, but can be
associated to Bacteria concerns, and in high enough levels, could be harmful.
Water Softener
Iron Filter
Tannin/Colour Remover
Control Valve
Control Valve
Direction Of Flow
Brine Line
Resin
Mineral
Tank
Tank
Regenerate
Brine Tank
Drain Line
Line
Pot. Perm.
Air Gapped
Drain
Feeder
Reverse Osmosis Systems-When and Where Does It Fit?
•An RO reduces TDS. The conductivity of the water is effected by the
TDS in the water. Generally speaking, Low TDS=Low Minerals and
Salts in water.
•RO systems are considered a purifier, due to the reduction of the
TDS, thus bringing water closer to it’s original form, without the
elements found in TDS.
•Use RO systems when water has taste or smell concerns. Use RO
water for an health related concern.
•An RO should always be the last product in the treatment chain,
except if an UV is used for post RO protection.
•An RO should only be used, whenever possible, on clear
Microbiological safe water.
Giardia & Cryptosporidium Cysts 99.99%
Nitrate 90 - 99%
Lead 95 - 99 %
Sodium 95 - 99%
Arsenic +5 95 -99 %
Copper 95 - 99 %
5 Stage Reverse Osmosis System
Ultraviolet Light (UV) Disinfection
Systems
•For the disinfection or sterilization of microorganisms.
•Specifically, UV affects the DNA structure of a Bacteria cell. The
sterilized Bacteria can not reproduce. Now considered harmless.
•The flow through a UV is critical for effective dosage. Flow Control
•The water quality entering the UV MUST be clear, or low in Turbidity.
•A sediment cartridge rated @ 5 Micron, minimum, should always be
used to pre treat the water, along with appropriate Filtration.
•A UV is always installed after pretreatment
•Often used at the point of entry (POE), a UV is more effective installed
as close to the point of use (POU) as possible.
UV System
•Flow GPM must be regulated to rating of UV
•Incoming water must be clear in colour
•Maintain constant power to unit
•Use surge protectors
Chemical Feed Pump Systems
Two types are most common:
•Solenoid/Diaphragm ( Pulsafeeder, LMI,)
•Peristaltic ( Stenner )
Both styles can be 115V or 230V.
Both can be on/off or remote controlled.
Both require attention to chemicals used, and sizing requirements.
Sizing a Pump:
Well Pump GPM x Required Dosage PPM x 1440 / Solution Strength PPM = Feed Rate in GPD
Dosage Calculations:
1 PPM Bleach =1 PPM Iron, 3 PPM Bleach = 1 PPM H2S,
* Plus add required residual to dosage. ( 0.5 to 1 PPM)
Solution Strength:
5% Bleach – 52,500PPM. 12.5% Bleach – 125,000PPM.
Choose a pump’s max. output that is twice the GPD required.
Rule of thumb for contact time is 20 Minutes. Actual pH and temp. of water does have an
impact on contact time required.
Non-Chlorinated Outside
Service Line.
If Required.
Pressure Tank
Optional
Chemical
Pump Flow
Meter
Contact Tank
To Service Line
Check Valve
Multi-Media
Filter
Carbon Filter
Injection Point
Chemical Injection Pump, and
Solution Tank.
Standard Chlorine Pump System
Well Pump
C/W Non-Chlorinated Outside Service
To Drinking
Water
Faucet
Usual Sequence or Placement of Common Filtration Products
RO System
5 Micron
Sediment
Multi-Media
Iron Filter
Filter
Water
Carbon
Filter
Softener
UV
Pressure Tank
Pot.Perm.
Feeder
Well Pump
Brine Tank