B. Braun SpaceCom

Download Report

Transcript B. Braun SpaceCom

Chapter 5.4
Chapter 5.4:
Strategic Marketing ICU&OR Systems
Nov 13, 2003
B. Braun SpaceCom – Product details

Overview

Communication protocols

Wireless communication

Web server application

Barcode

Universal Serial Bus (USB)
Sales Manual B.Braun Space
Chapter 5.4 - 1
B. Braun SpaceCom – Features & Benefits
B.Braun SpaceCom




is a central communication interface for external devices with
different physical connectors
provides an open structure which allows the integration of
customized software solutions
works with operating system Windows CE.NET 4.2
offers full support of Windows-compatible hardware
 USB Memory Sticks
 Wireless LAN cards
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 2
B. Braun SpaceCom – Features & Benefits
SpaceCom is

integrated in SpaceStation

powered by the internal power supply of
SpaceStation. An optional rechargeable
battery can be integrated into the
SpaceStation to power the SpaceCom
during transport.

SpaceCom
common interface for up to 24 pumps
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 3
B. Braun SpaceCom – Features & Benefits
Interfaces
 Compact Flash
Card for Wireless
LAN
 USB-Master port
 RS232
 PS/2 for
Barcode
 USB Slave
Port
 Ethernet RJ45
All interfaces can be
used for
communication.
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 4
B. Braun SpaceCom – Features & Benefits
Communication Protocols





To be compatible to current PDM-Systems, BCC communication
protocol version 3.2x is supported
Other protocols can be easily programmed and downloaded to
SpaceCom
All data from the pumps are available in an internal database
which can be interfaced
The protocol structure can be adapted to the requirements of the
external device
SpaceCom is very flexible and offers an open interface which can
be programmed individually
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 5
B. Braun SpaceCom – Features & Benefits
Wireless LAN
 onboard Compact Flash Card allows integration into standard
W-LAN networks
 online data communication even in transport situation
A wireless network installation in a hospital is required and also
the ability of a PDMS to handle information in this way.
Server
Access points
Laptop
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Laptop
Laptop
Chapter 5.4 - 6
B. Braun SpaceCom – Features & Benefits
WEB Server application

B.Braun Space information can be requested via a standard
internet browser (Ethernet or W-LAN interface)
 Internet configuration/parameters of SpaceCom (DHCP, IPAddress and Port, Name) can be set up via SpaceControl or
Service-Tool
Outstanding advantages
1.
2.
3.
The technology allows multi user access and provides a simple
and low cost alternative to realize a central display.
The web page can be integrated into a PDMS (as a separate
application)
A central supervisor desk (ICU, OR, ..) can be realized without
additional software installation
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 7
B. Braun SpaceCom – Features & Benefits
The system is displayed in a
graphic and information from
every pump can be
requested.
Additional information like
history data and data for service
purpose are available.
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 8
B. Braun SpaceCom – Features & Benefits
1a
Proposal data as a prescription
list
1. A PDMS offers the possibility to
send prescription to
Space-System
prescription by a
physician
prepare a prescription on drugs and
1
infusions in a special menu. The
prescription is done by a physician
and activated by the care giver.
prescription
1a. The care giver activates the
prescription at the described time
and can print a list of drugs and
infusion for preparation.
2. The drugs and the infusions can be
prepared and labeled. This is
normally done in a separate room.
preparation
3. The information from the PDMS are
2 Drug
and labeling
send to the SpaceStation and the
Sales Manual B.Braun Space
Strategic Marketing ICU&OR
Systems
pumps
are waiting for activation.
Nov 13, 2003
3
Selection from
prescription list
during loading
the pumps
Chapter 5.4 - 9
B. Braun SpaceCom – Features & Benefits
Barcode interface supports two different types of barcodes
Barcode interface: Code 128
This bar code sticker can contain drug name and
drug ID, delivery rate, dose rate information like
concentration, quantity of active agent, volume
and time pre selection, look-up function
Barcode interface: PDF 417

PDF417 is a two dimensional bar code
 it carries up to 1800 ASCII characters and allows to
store a complete information set for a drug
A complete data set for a drug can be stored in one label. No link to the data base of a pump is
necessary. Rate limits, bolus information and profile description are coming with the drug.
Increase safety and convenience by working with barcodes.
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 10
B. Braun SpaceCom – Features & Benefits
Barcode interface

Different barcode readers for the two types of barcodes are
available
to read Code 128 you can use the “normal” reader as
used with the fm system
2. to read the PDF417 a special image reader has to be
used.
1.
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 11
B. Braun SpaceCom – Features & Benefits
Universal Serial Bus (USB)
The USB Slave allows to connect a PC or PDMS, and the USB
Master to connect USB memory sticks or in future of other USB
slave devices.
Direct connection with USB
memory stick to the USB master
port of the SpaceCom
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Direct connection of a PC or
PDMS/CIS to the USB slave
port of the SpaceCom
Chapter 5.4 - 12
B. Braun SpaceCom – Features & Benefits
How to demonstrate the SpaceCom features ?
A software like BCCshow and BCCsim, which is used to demonstrate the
features in respect of data communication of the fm system, will be provided.
This tool can be used for customer presentations as well as for development
purpose.
All interfaces for communication and all features can be operated.
Communication via:
 Ethernet, USB, Wireless and RS232
 Features of handling proposal data, send data to a single pump and
send
prescription list
 Web-Server application, Windows Internet-Explorer can be used
also
Strategic Marketing ICU&OR Systems
Nov 13, 2003
Sales Manual B.Braun Space
Chapter 5.4 - 13