IR transmitter : OLCT IR
OLCT IR: onshore and
offshore installations
• You encounter some of the most severe
constraints and infrared technology is very
often the only solution.
OLCT IR
• The extra-tough OLCT IR transmitter detector with
infrared sensor for top performance provides top-end
gas flammable detection reliability :
• insensible to poisoning ( silicon vapours,
hydrogen sulphide, chlorinated products …)
• resistant to aggressive substances
• long-life, highly-resistant sensor
• low maintenance and non-intrusive
calibration...
OLCT IR
• The transmitter OLCT IR
is designed for detection of
flammable gas :
• hydrocarbons ,
• methane,propane/butane as
standard
• and others on request…
• Note : functional in inert
gas atmosphere .
OLCT IR : concept
• OLCT IR concept is
based on
measurement of
infrared radiation
passing through a
volume of gas.
• Working IR pulsed source
• Reference IR pulsed source.
OLCT IR
Reference wave-length
• Since most gases have unique
absorption spectra, they can
easily be identified by proper
selection of an infrared wavelength at which absorption is
measured
• l ’OLCT IR = two standard
versions :
• OLCT IR CH4
• OLCT IR HC .
Recommanded versions
• CH4 version
• HC version
• ALCANES:butane,propane,hexane,
ethane, pentane ...
• ALCOHOLS:ethanol,methanol,
• ALCENES:
ethylene,propylene,1butene,1-3butadienne…
• AROMATICS:
benzene,toluene,0-Xylene
(m- ; p- ),Styrene...
propanol...
• CETONES:acetone,2Butanone,cyclohexanone...
• ETHERS: ethyl acetate, methyl
methacrylate, ethyl acrylate...
• ESSENCES:
supers,gasoil,gazole,kerozene,essence
of terebenthine...
• SOLVANTS:White spirit...
« CH4 » = recommanded version
according to these examples :
• ALCENES
• AROMATICS
OLCTIR CH4 calibré CH4 : Réponse calculée aux aromatiques
100,0
90,0
80,0
Rep [% LIE CH4]
70,0
Méthane CH4
Benzène C6H6
Toluène C7H8
o-Xylène C8H10
m-Xylène C8H10
p-Xylène C8H10
Styrène C8H8
60,0
50,0
40,0
30,0
20,0
10,0
0,0
0,0
10,0
20,0
30,0
40,0
50,0
Conc [% LIE]
60,0
70,0
80,0
90,0
100,0
« HC » = recommanded version
according to these examples :
ALCANES
ALCOHOLS
CETONES
ESTHERS
ESSENCES
SOLVANTS ...
OLCT IR HC calibré C3H8 : Réponse calculée aux essences & solvants
100.0
90.0
80.0
70.0
Rep [% LIE C3H8]
•
•
•
•
•
•
Propane C3H8
Butane C4H10
Super SP98
Super plombé 97
Gasoil ou Gazole C9 - C25
Kérosène (JP4) C10 - C16
Essence de térébenthine (Turpentine)
White Spirit
60.0
50.0
40.0
30.0
20.0
10.0
0.0
0.0
10.0
20.0
30.0
40.0
50.0
Conc [% LIE]
60.0
70.0
80.0
90.0
100.0
OLCT IR compared with cataltytic
cells : major advantages
• High gas concentration does not saturate the transmitted
signal
• insensitive to poisoning
• low dispersion of response to various gases
• presence of oxygen is not required
• humidity ( without condensation) has no influence on accuracy
• the gas flow rate has no influence on accuracy .
Other ADVANTAGES
Proven high reliability and long-term stability
no calibration(1) and low maintenance required during
equipment lifetime (10 to 15 years)
Automatic self test
Immunity to poisonning from H2S, silicone and other agents
(1)
OLCT IR has a continous self-test function
Proven leading-edge technology
• « low maintenance » efficiency: electronics of
the OLCT IR guarantee extreme accuracy and
constant stability ...
• The answer to spurious alarms: an ability to
ignore external substances that trigger false
alarms ...
• non -intrusive calibration (magnetic switch)
OLCT IR : maintenance
• The OLCT IR has been designed to requiere a
minimum of maintenance :
• it ’s only necessary to inspect visually that the
weather protection is not clogged in heavily
contaminated areas
• and be sure that the optical surfaces are clean*.
* use an equal-part mixture of isopropyl alcohol and water.
Two configurations for adapting to
your site :
• Housing « E » =
standalone version , fitted
with a terminal
compartment and a cable
gland.
• Housing « M25 » = freefitting version , fitted with
a threading and 3-wire
output for electrical
connections.
DIMENSIONS
WEIGHT: 2,3 to 3,1 kgs
INSTALLATION : indications
– The location of each detector should preferably be determined at the
system design stage :
– where gas leakage is most likely to occur
– It should be considered whether the gas in question is heavier or lighter
than air ?
– The detector can be used with the weather protection (réf : 6124976)
– The detector should not be mounted where it could be exposed to water
drenching
INSTALLATION : orientation
– L’OLCT IR must be
mounted so that the flow
direction indicator
must point upwards.
INSTALLATION : information
– Housing “ E ” must be
mounted so that the
longitudinal axis of OLCT
IR is horizontal.
– This
will
prevent
accumulation of water and
dust on the optics
– for this purpose, mounting
bracket is avaible : réf :
6132380.
Accessories
• Calibration sample flow
housing.
•
Leather test nozzle:
allows the functional test
by injecting a calibration
gas .
Accessories
• Weather protection kit :
• Mounting bracket:
Accessories
•
« mosquito » Filter
• Weather protection
Accessories
• Interface-module allows a direct transmetter
4-20mA linking to a channel initially
connected with a catalytic gas detector
(analog signal in mv):
• and that, without other modifications of
installation (cable…), wiring and electronics
(control unit) !
TECHNICAL CARACTERISTICS
Detection range: 0-100 % LEL
response time : T50 < 10 secondes with calibration cap
power supply: 16 à 30VCC, 3 active wires
• max. resistance per wire capt./control unit =
16 ohms ( 500 m with 1,5 mm2) and with 21 VCC of power
• 4-20 mA signal : max. impedance = 300 ohms
• average power consumption = 8W (max 12W)
IP66
Housing material: stainless steel 316L
Operating temperature: from -30°C to + 55°C
• Storage temperature : from 0 to +30°C .
Main applications:
•
•
•
•
•
•
Offshore Platforms,
petrochemical plants,
Chemical industries,
Reffineries,
Marine,
Waste disposal plants …