High Input harmonics
Download
Report
Transcript High Input harmonics
POWER ELECTRONICS
Multi-Step VSI
vs
GTO CSI
01 GTO CSI – Current Source Inverter – 6 pulses – with transformer
Font: High-Power Converters
and ac Drives. By Bin Wu
LINE UP SIDE
Poor input power factor at low loads
with SCR
High Input harmonics, input and
output filters needed.
CMV is transferred to the transformer
winding
Low overall efficiency due to
transformer and high switching
losses.
INVERTER
Link inductor stores the energy
Requires controlled front end that
add extra complexity.
High switching losses
High power consumption at low
loads.
High current stress on output
capacitors
Narrow speed range
MOTOR SIDE
High motor THDi at low loads or low
frequency.
CMV stress on motor winding due to
input transformer (x1.5)
Potential torsional resonance between
motor & capacitors
Limited starting performance &
dynamic response. (Not used for
conveyors, cranes, mills, …etc.)
Power Electronics España S.L. © reserves the right to modify the content without prior notice
02 GTO CSI – Current Source Inverter – 6 pulses – without transformer
Font: High-Power Converters
and ac Drives. By Bin Wu
LINE UP SIDE
Poor input power factor with SCR
front end
Highly potential LC resonances
High Input harmonics, input and
output filters needed.
INVERTER
MOTOR SIDE
Link inductor stores the energy
Requires controlled front end that add
extra complexity.
High switching losses
High power consumption at low loads.
High current stress on output
capacitors
Narrow speed range
High motor THDi at low loads or low
frequency.
Potential torsional resonance between
motor & capacitors
High CMV stress on motor winding,
CMC filters and double isolated motor
needed. (x2)
Limited starting performance (overload
& torque)
Slow dynamic response. (Not used for
Power Electronics España S.L. © reserves the right to modify the content without prior notice
conveyors, cranes, mills, …etc.)
03 VSI – Multi Step PWM modulation with low Voltage IGBt
STORED ENERGY
LINE UP SIDE
INVERTER
MOTOR SIDE
High power factor
>0.9 under any load
condition
High efficiency >96%
over 20% load.
Low harmonics
THDi<5%
No additional line-up
costs
DC link Capacitors
store the energy
Large unstressed low
voltage parts count,
but reduced spare
parts.
Redundancy option
adds parts and
decreases MTBF
Low switching losses.
Available N+1,2,3
redundancy
Regeneration available
with IGBt rectifier
Low motor THD at any
load and frequency
condition
High break away
torque
High overload capacity
(150%)
Fast and accurate
transient response
Reduced CMV stress
on motor winding (x1)
Power Electronics España S.L. © reserves the right to modify the content without prior notice
04 Summary
Efficiency
Full Power and Frequency
Low Power (50%)
Reliability
Components
MTBF
Power Quality
Harmonics
Potential Resonance
Power Factor
Motor issues
Break away torque
Dynamic response
THDI/HVF
CMV (Common Mode Voltage)
GTO-CSI
VSI- Multi Step PWM
93%
86%
96.5%
96%
Low, high components count
1.5 years
High, low components count
(Low voltage & redundant)
>10 years
High for SCR, lower for IGCTs or Multi-pulse
systems (12p, 18p)
High for LC filters
Low for SCR
Low, at any load condition meets
IEEE519
No
High, at any load condition
Low
Limited by the DC choke / filter
High at low loads, High stress on capacitors
High Stress, requires input isolation
transformer or common mode voltage choke
High
Fast, no hardware limitations
Low, multi-step topology
No, isolation transformer and
controlled neutral point
Size
Non integrated transformer
Input choke integrated
Fully integrated
Extra space required
Standard
-
Standard
Power Electronics España S.L. © reserves the right to modify the content without prior notice